Proper storage is critical to maintain the integrity of the asphalt-based protection board and its associated materials. As outlined in Sections 5 and 6 of D6451/D6451M, all materials must be delivered in the supplier’s original containers and packaging.
Adhesives and mastics require tightly closed original containers stored under the specific environmental conditions recommended by the manufacturer. Solvent-bearing adhesives require strict fire safety precautions, as noted in Section 8.
| 📜 Material Component | 🟦 Storage Requirement | 📐 Handling Protocol |
|---|---|---|
| Semi-Rigid Protection Board | Horizontal, in supplier’s original packaging | Protect from sun, rain, and dust (Section 6.2) |
| Adhesive & Mastic | Tightly closed original containers | Store per manufacturer conditions (Section 6.1) |
| Solvent-Bearing Adhesives | Fire-safe area (flammable) | Avoid open flame or sparks (Section 8.1) |
Section 7 of the standard establishes strict criteria for installation materials. Any adhesive, mastic, or tape used with the protection board must be “acceptable to or have been recommended by the waterproofing membrane manufacturer or supplier.” This ensures the entire assembly functions as a compatible system without risk of chemical attack or adhesive failure on the waterproofing membrane.
| 📋 Component | ⚡ Compatibility & Approval Requirement |
|---|---|
| Protection Board Adhesive | Must be recommended by the membrane manufacturer (Section 7.1) |
| Joint Mastic or Tape | Must be recommended by the membrane manufacturer (Section 7.2) |
| System Integrity | Chemical compatibility between membrane, adhesive, and board is required |
The environmental conditions for installation are governed by the material suppliers. Section 9.1 states that installation may only proceed under the conditions recommended by the suppliers of the adhesive and the protection board. This typically includes ambient temperature ranges, surface moisture limits, and weather forecasts which are defined in the manufacturer’s published technical data.
The overall purpose of the application guide is defined in Section 4. Proper installation of the semi-rigid board is necessary to prevent damage to the waterproofing membrane during backfilling, paving, or other construction operations, and to minimize the effects of long-term soil stresses against the waterproofed structure.
The semi-rigid protection board provides a physical barrier to protect below-grade and wearing-surface waterproofing membranes from damage during backfilling and paving operations, and helps distribute soil stresses (Section 4.1).