ASTM Standard D6029/D6029M-20 covers the Hantush-Jacob analytical procedure for determining the transmissivity, storage coefficient of a confined aquifer, and the leakance of an overlying or underlying confining bed with negligible storage.
This practice is designed for analyzing constant-rate pumping or injection test data. The aquifer must be overlain or underlain by a confining bed with uniform hydraulic conductivity and thickness, negligible storage capacity, and bounded by a constant head zone on its distal side. The adjacent confining bed is assumed to be impermeable. The analytical procedure is specifically intended for use in conjunction with Test Method D4050.
Drawdown or head data from observation wells or piezometers are matched to Hantush-Jacob type curves. This analysis yields the transmissivity (T) and storage coefficient (S) of the aquifer, as well as the leakance value (K’/b’) of the confining bed.
A critical requirement for compliance is the independent use of unit systems. All values must be computed exclusively in either SI units or inch-pound units; combining values from the two systems may result in non-conformance with the standard. All observed and calculated values must also conform to the significant digit and rounding guidelines established in Practice D6026.