SAE J1113-22 (cancelled in 2010 and superseded by ISO 11452-8) provides standardized methods for evaluating the immunity of vehicle components to radiated magnetic fields from 15 Hz to 30 kHz. Despite its cancellation, the procedures remain widely referenced for legacy systems and as a technical baseline. This article breaks down the key test methods, setup requirements, and practical considerations for engineers performing radiated magnetic field immunity testing.
The standard specifies two primary methods: the radiating loop method (based on MIL STD 461E) and the Helmholtz coil method. Both methods aim to generate a controlled magnetic field at the device under test (DUT) and include calibration, setup, and DUT orientation requirements. The test frequency steps follow MIL-STD-461E Table III, extended down to 15 Hz. As noted in the standard, a detailed test plan must be prepared before testing, including the test method, test points, and DUT axes.
The choice between the two methods depends on DUT size, field uniformity needs, and test objectives. The table below summarizes key differences:
| Aspect | Radiating Loop Method | Helmholtz Coil Method |
|---|---|---|
| Frequency Range | 15 Hz to 30 kHz | 15 Hz to 30 kHz |
| Field Reference | Coil current (calibration or calculation) | Coil current or calculated field (if coils accurately spaced one radius apart) |
| DUT Size Constraint | Partitioned into 100 mm × 100 mm grid per face | Must fit within uniform field region (cube shape preferred; see Figure 3 for dimensions) |
| Test Points | Multiple points per face, plus connectors, harness, and magnetic sensors | Three orthogonal axes (X, Y, Z) of the DUT |
| Calibration | Required without DUT at each frequency | Not required if coils are constructed accurately; otherwise perform calibration with field monitor |
| Self-Resonance Consideration | Not explicitly addressed for loop; coils from MIL STD 461E are standard | Coil self-resonant frequency must not be at or below 30 kHz |
For the radiating loop method, calibration involves placing a magnetic field intensity monitor at the test distance (50 mm) and recording coil current versus field strength for each frequency. For the Helmholtz coil method, calibration is optional if coils are built to high precision; otherwise, a calibration setup (Figure 5) is used.
Proper setup also includes placing the harness on a non-conductive, low-permeability support and terminating all wires per the actual vehicle application. The DUT must be operated under typical loading and environmental conditions to ensure repeatable results.
The radiating loop method is suited for smaller DUTs and offers local field application at multiple points, while the Helmholtz coil method provides a uniform field over a larger volume and requires fewer test orientations. The choice depends on DUT size and test objectives.
The coil radius must be at least the largest dimension of the DUT (for a cube-shaped DUT). The coils must be spaced exactly one radius apart, and turns should be wound consistently. For non-cubic DUTs, consult the published article by Bronaugh referenced in the standard.
SAE J1113-22 was cancelled in 2010 and superseded by ISO 11452-8. However, many existing test facilities and legacy requirements still reference this standard. The technical details remain valid for designing immunity tests and understanding the historical approach.
If the coil self-resonates at or below 30 kHz, the field will not follow the expected current-to-field relationship, leading to unreliable test results. Always verify that the coil’s self-resonant frequency is above the highest test frequency.
For further details, refer to the original standard or ISO 11452-8. Proper planning and adherence to setup guidelines will help ensure valid and repeatable immunity testing results.