Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
SAE J2843-2019 defines the minimum requirements for equipment used to recover, recycle, and recharge R-1234yf refrigerant in mobile air-conditioning (MAC) systems. This standard, revised in July 2019, addresses the unique challenges of handling mildly flammable (ASHRAE Class 2L) refrigerants while ensuring recharging accuracy, refrigerant purity per SAE J2099, and robust safety in automotive service environments. This article breaks down the core specifications, engineering design considerations, and how to certify compliant equipment.
The standard applies to on-site recovery, recycling, and recharging equipment for R-1234yf (HFO-1234yf) refrigerant. Its primary goal is to ensure that recycled R-1234yf delivers the same performance and durability as virgin refrigerant when used in MAC systems. Equipment must operate continuously in ambient temperatures from 10 to 50 °C and be suitable for automotive service garages.
Key requirements include:
Designing equipment that meets J2843 requires attention to several critical subsystems:
An effective desiccant package is mandatory. The desiccant must have a mineral acid capacity of at least 5% by weight. Oil separation must occur before the desiccant filter to prolong its life. The equipment must include a moisture indicator that locks out operation when the filter is saturated, and an identification system to ensure the filter is replaced before resetting.
An in-line filter must trap particulates of 0.015 mm spherical diameter or larger. This prevents contaminants from entering the system during recharging.
Automatic NCG purge or an alert system is required. For manual purge equipment, a method to determine refrigerant temperature and pressure/temperature relationship must be provided. Refrigerant loss from purging must not exceed 5% of the total refrigerant removed.
Service hose assemblies inside the equipment are limited to 0.91 m length, with a tensile pull requirement of at least 113 kg and permeation ≤4.9 kg/m²/year. Scales must maintain accuracy when moved, verified by a performance test per Section 10.
The standard includes detailed test procedures (Sections 8, 9, 10) to verify that equipment meets performance and accuracy requirements. Manufacturers must test the shortest and longest hose lengths if multiple lengths are offered.
| Parameter | Requirement |
|---|---|
| Refrigerant | R-1234yf only |
| Temperature Range | 10 to 50 °C (50 to 120 °F) |
| Charge Accuracy | Per Section 9 |
| Desiccant Acid Capacity | ≥5% by weight |
| Filter Particulate Size | ≥0.015 mm |
| Internal Hose Length | ≤0.91 m (3 ft) |
| Hose Permeation | ≤4.9 kg/m²/year |
| NCG Purge Loss Limit | ≤5% of recovered refrigerant |
| Certification | SAE J2911 / EPA-approved independent test |
The standard specifies accuracy requirements in Section 9. Equipment must be capable of recharging to within the tolerances defined for mobile air-conditioning systems. Exact values are given in the standard and should be verified during certification testing.
J2843 includes construction requirements to mitigate risks from R-1234yf, which is classified as mildly flammable (Class 2L). Electrical components must meet applicable safety standards (e.g., UL 1963 with specific exceptions), and any released vapor must be directed away from ignition sources. Hoses have permeation limits to reduce refrigerant escape.
SAE J2911 provides the procedure for certifying that equipment meets the requirements of SAE J2843. In the U.S., certification must be obtained from an independent testing organization approved under EPA regulations. It is the manufacturer’s responsibility to ensure their equipment passes all performance tests before claiming compliance.
The equipment monitors moisture load and will alert the user when the end of filter life is approaching. A lockout prevents further operation until the filter is replaced. The standard also requires an identification system to ensure a new filter is installed before the machine can be reset.
By adhering to SAE J2843-2019, manufacturers can produce robust, safe, and efficient service equipment that supports the growing fleet of R-1234yf MAC systems while minimizing environmental impact and maintaining system performance.