Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
This standard, developed with the U.S. Coast Guard, specifies requirements for nonmetallic flexible hose assemblies in commercial marine vessels. It covers various systems including fluid power, fuel, lube oil, water, and pneumatic systems. Compliance ensures safe operations in harsh marine environments.
The standard defines several service codes based on application and performance. The table below summarizes the key requirements.
| Code | Application | Maximum Working Pressure | Reinforcement |
|---|---|---|---|
| HF | All Services | As rated | Steel wire with or without textile |
| H | Fluid Power | As rated | Steel wire or textile |
| F | Lube Oil and Fuel | As rated | Steel wire with or without textile |
| VW | Vital and Nonvital Water | As rated | Steel wire or textile |
| NVW | Nonvital Water and Pneumatic | 0.34 MPa | Optional |
Engineering Design Insight 🛠️: When selecting hoses, consider that Code HF hoses must meet all requirements for Codes H, F, VW, and NVW, making them suitable for multiple services. Fittings must comply with SAE J1475, and push-on fittings or single worm-gear clamps are not acceptable.
The standard mandates several critical tests to ensure hose reliability.
Hose assemblies are immersed in synthetic seawater per ASTM D1141-98 for 48 hours at 70°C, then aged, and burst tested. Burst must not occur below four times the working pressure, and wire reinforcement must show no red rust.
Flame resistance is tested per MSHA 30 CFR 18.65, or a fire sleeve can be used. Fire resistance has two methods: the 2.5-minute test (Type A) and the 30-minute test (Type B).
🔍 Note: Manufacturers can qualify hoses using either fire test method. Type B is the preferred method for new qualifications.
Qualification involves submitting test results to SAE for listing in SAE J1942-1. The U.S. Coast Guard is notified annually.
Common Mistakes: Using improper fittings like push-on connections or failing the immersion-burst test due to corrosion. Ensure compliance with all test requirements for the specific service code.
Type A uses a 2.5-minute fire exposure, while Type B uses a 30-minute test. Type B is becoming the preferred method for qualification.
Yes, but it must meet the requirements for both applications. For example, Code HF hoses can be used for all services, but Code F hoses are only acceptable for fuel, lube oil, and water systems.
Fittings must conform to SAE J1475. Push-on fittings, quick disconnect couplings, and single worm-gear clamps are unacceptable.