Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Modern engine cooling systems have evolved significantly from single jacket water circuits. The introduction of emissions controls, electronic components, and hybrid propulsion has driven the need for separate low-temperature (LT) coolant circuits. SAE J3136-2018 provides standardized nomenclature and application guidance for these circuits, covering both on- and off-highway gasoline and diesel engines. This article distills the key concepts and practical insights from the standard.
J3136 defines three primary methods for regulating coolant temperature in both high-temperature (HT) and low-temperature (LT) circuits: outlet regulation, inlet regulation, and electronic regulation. The key differentiator is the location of the temperature sensor relative to the heat source.
| Method | Sensor Location | Valve Orientation | Typical Application |
|---|---|---|---|
| Outlet Regulation | Outlet of heat source or radiator inlet | Splits one inlet flow into two outlet streams (bypass) | Simple systems where engine outlet temperature is controlled |
| Inlet Regulation | Inlet to heat source | Mixes two inlet streams (radiator and bypass) into one outlet | Systems requiring controlled inlet temperature for sensitive components |
| Electronic Regulation | Either inlet or outlet, with electronic sensing | Can use electrically actuated valves or variable speed fan drives | Modern thermal management with precise control |
Outlet regulation places the temperature-sensing element at the outlet of the heat source or the radiator inlet. Coolant is bypassed back to the heat source inlet when below set point. Inlet regulation senses temperature entering the heat source and mixes flows to achieve the desired temperature. Electronic regulation replaces wax pellet thermostats with electrically actuated valves or variable speed fans, enabling more flexible and responsive control.
Traditional jacket water circuits operate at 85–90 °C. However, emissions reduction systems like EGR coolers and electronics (e.g., battery thermal management) require lower temperatures. SAE J3136 explains how dedicating a separate low-temperature circuit offers several advantages:
When designing a dual-circuit system, engineers must decide whether to use a single pump with split circuits or dedicated pumps for each circuit. The standard provides schematics and guidance for these configurations. Low-temperature circuits inherently respond better to dynamic loads because they can be sized for specific heat rejection requirements.
For further details, refer to SAE J3136-2018 and related standards such as SAE J3142 (Thermal Flow Control Valve Nomenclature) and SAE J3073 (Battery Thermal Management).
No download files available yet