Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
ASTM D6194-23 defines a standardized procedure for determining the minimum temperature required to ignite insulating materials using a controlled, electrically-heated glowing heat source. This preliminary test method is designed to differentiate between the susceptibilities of materials regarding their resistance to ignition when exposed to a thermal stress.
The method applies specifically to molded or sheet materials within a thickness range of 0.25 mm to 6.4 mm. It is critical to note that this standard is not valid for assessing the ignition behavior of complete electrotechnical equipment, as the design of the final product significantly influences heat transfer between adjacent mechanical components. The values stated in SI units are to be regarded as standard per IEEE/ASTM SI-10.
| 🟦 Parameter | 📏 Specification / Value | 🎯 Notes |
|---|---|---|
| Material Thickness | 0.25 mm to 6.4 mm | Applies to molded or sheet materials (Section 1.2) |
| Test Measurement | Minimum ignition temperature | via electrically-heated glow wire (Section 1.1) |
| Related IEC Standard (GWFI) | IEC 60695-2-12 | Data is technically similar (Note 1) |
| Related IEC Standard (GWIT) | IEC 60695-2-13 | Data is technically similar (Note 1) |
| Unit System | SI Units | Standardized per IEEE/ASTM SI-10 (Section 1.5) |
The glow-wire ignition test relies on careful calibration and adherence to referenced standards. Referenced documents include Test Method E220 for thermocouple calibration and Specification E230/E230M for temperature-electromotive force tables. Familiarity with Terminology E176 (Fire Standards), ISO 13943, and IEC 60695-4 is essential for understanding the specific terminology related to fire testing.
Safety: This method requires strict adherence to specific precautionary statements outlined in Section 9 of the standard. The standard explicitly warns that fire testing is inherently hazardous, and adequate safeguards for personnel and property must be employed during testing (Section 1.7). It is the responsibility of the user to establish appropriate safety, health, and environmental practices.
The primary purpose is to determine the minimum temperature required to ignite insulating materials using a glowing heat source. It differentiates between materials based on their resistance to ignition from an electrically-heated source.
Although differing in approach and detail, data obtained from D6194-23 to determine the Glow-Wire Flammability Index (GWFI) and the Glow-Wire Ignition Temperature (GWIT) are technically similar to data obtained under IEC 60695-2-12 and IEC 60695-2-13, respectively.
This test method applies specifically to molded or sheet materials available in thicknesses ranging from 0.25 mm to 6.4 mm.
No. As stated in Section 1.3, this test method is not valid for determining the ignition behavior of complete electrotechnical equipment because the design of the final product influences heat transfer between adjacent parts. It is strictly a material-level characterization test and does not by itself incorporate all factors for fire hazard assessment under actual fire conditions.