Poly(Vinyl Chloride) Sheets Roofing must conform to the requirements of ASTM Specification D4434 (Section 4.1). Lap seam sealant, when required by the manufacturer/supplier, shall be a compatible sealant applied to the exposed edge of the seam (Section 4.2). Mechanical affixments—including fasteners, plates, discs, bars, or strips—must meet the corrosion resistance guidelines of FM Standard 4470 and the specific requirements of the manufacturer/supplier (Section 4.3).
Deliver all materials in the supplier’s unopened containers and packages (Section 5.1). Store roll goods in a horizontal position under protective covering to prevent the supplier’s markings from being destroyed (Section 6.1). Store solvents in proper containers to prevent dilution or contamination (Section 6.2). Keep flammable materials in original closed containers away from any ignition source (Section 6.3). During installation, shut down roof top air handling equipment and air intakes to reduce odors from entering the building (Section 7.2). Install roofing components only during weather conditions that do not interfere with proper application (Section 8.1).
The following table summarizes critical material and storage requirements per ASTM D5082-99:
| 🟦 Component | 📏 Specification | 🎯 Compliance Standard |
|---|---|---|
| PVC Sheet Roofing | Conforms to D4434 | ASTM D4434 |
| Mechanical Fasteners | Corrosion Resistance | FM Standard 4470 |
| Plates, Discs, Bars, Strips | Corrosion Resistance | FM Standard 4470 |
| Lap Seam Sealant | Compatible sealant | Manufacturer/Supplier Requirement |
| Roll Goods Storage | Horizontal position | Prevent marking damage |