Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
ASTM D4894-19 (Reapproved 2024) defines specifications for granular polytetrafluoroethylene (PTFE) materials used in molding and ram extrusion. These resins are homopolymers of tetrafluoroethylene or modified homopolymers containing not more than 1% by weight of other fluoromonomers. The standard explicitly excludes materials that have been preformed or molded, as well as mixtures with colorants, fillers, plasticizers, or reprocessed resin.
Processing of these PTFE resins differs from conventional thermoplastics due to their unique viscoelastic behavior at processing temperatures. Instead, methods similar to powder metallurgy or ceramics are employed, along with specialized extrusion techniques. The standard provides the basis for identifying resin types through required test methods and properties. The values stated in SI units are regarded as standard, in accordance with IEEE/ASTM SI-10.
The standard references several ASTM test methods for evaluating PTFE granular resins. Conditioning of test specimens is performed according to Practice D618. Density and specific gravity are measured using Test Methods D792. Tensile properties are determined via Test Method D1708 with microtensile specimens. Test Methods D1895 covers apparent density, bulk factor, and pourability, which are critical for processing.
Additional characterization includes differential scanning calorimetry per D4591 for transition temperatures and sieving analysis per E11 for particle size distribution. The standard also references specifications for PTFE tubing (D3295), aqueous dispersions (D4441), and filled PTFE materials (D4745). Packaging and packing are governed by Practice D3892.
| 🔧 Test Method | 📏 Property | 🎯 Typical Requirement |
|---|---|---|
| D792 | Specific Gravity | 2.14 – 2.20 |
| D1708 | Tensile Strength | ≥ 27.6 MPa (4000 psi) |
| D1708 | Elongation at Break | ≥ 200% |
| D1895 | Apparent Density | 0.5 – 0.8 g/cm³ |
| D4591 | Melting Peak Temperature | 327 ± 10°C |
These values are typical for PTFE granular resins under D4894-19. Actual requirements depend on the specific resin type and application. Consult the standard for complete specifications.
| 🟦 Standard | 📐 Application |
|---|---|
| D618 | Conditioning plastics for testing |
| D792 | Density and specific gravity |
| D1708 | Tensile properties (microtensile) |
| D1895 | Apparent density, bulk factor, pourability |
| D4591 | Transition temperatures by DSC |
| E11 | Test sieve specifications |