ASTM D450/D450M – 07 (Reapproved 2024) defines the comprehensive material specification for coal-tar pitch used in the construction of built-up roofing (BUR), dampproofing, and membrane waterproofing systems. The standard covers two distinct types of pitch, each refined from selected crudes through suitable processing to ensure homogeneity and strict conformance to physical property limits.
Type I is formulated for use in built-up roofing, dampproofing, and membrane waterproofing systems. Type II is designated for use in dampproofing and membrane waterproofing applications specifically. This classification allows specifiers to select the optimal material based on the intended exposure conditions and service requirements of the assembly.
The standard mandates that coal-tar pitch shall be homogeneous and free of water. Each type must strictly conform to the physical properties prescribed in Table 1, which are critical for safe application temperatures and long-term durability of the roofing or waterproofing membrane. The table below summarizes the key property requirements and their corresponding ASTM test methods.
| 🟦 Property | 📏 Test Method | 🎯 Type I Requirement | 🎯 Type II Requirement |
|---|---|---|---|
| Softening Point (Ring-and-Ball, °C) | D36/D36M or D3461 | 52.0 – 60.0 | 54.0 – 62.0 |
| Flash Point (Cleveland Open Cup) | D92 | 204 °C (400 °F) min | 204 °C (400 °F) min |
| Water Content (mass %) | D95 | 0.5 max | 0.5 max |
| Specific Gravity (38 °C / 25 °C) | D70/D70M | 1.24 – 1.34 | 1.24 – 1.34 |
| Pitch Soluble in Carbon Disulfide (mass %) | D4 | 98 min | 98 min |
| Ash (mass %) | D2415 | 0.5 max | 0.5 max |
Proper material sampling is critical for compliance testing. Section 6.1.1 explicitly mandates that all sampling of coal-tar pitch for verification shall be conducted in accordance with Practice D140/D140M. This practice covers the standard procedures for obtaining representative samples of bituminous materials from storage tanks, tank cars, or shipping containers.
The standard enforces strict purity limits, including a maximum ash content of 0.5% (D2415) and a minimum solubility in carbon disulfide of 98% (D4), ensuring a high-quality binder with minimal inert fillers. Adherence to these test methods and the specified physical properties is essential for ensuring the performance and longevity of the installed roofing or waterproofing system.
ASTM D450 defines two types. Type I is suitable for built-up roofing, dampproofing, and membrane waterproofing systems. Type II is specifically designated for dampproofing and membrane waterproofing systems, offering a distinct softening point range optimized for typically vertical or concealed applications.
While the Mettler Cup-and-Ball method (D3461) is an acceptable alternative for routine testing, Test Method D36/D36M (Ring-and-Ball Apparatus) is explicitly designated as the referee method in Section 6.1.4 for resolving any disagreements between the purchaser and the seller.
The standard enforces a minimum Flash Point of 204 °C (400 °F) per D92 to ensure safe heating to application temperatures. It also strictly enforces a Water Content maximum of 0.5% per D95 to prevent hazardous foaming and violent steam expansion during the heating process, which is a critical safety concern in the field.
Per Section 1.2, the values stated in SI units and inch-pound units are regarded separately as standard and are not exact equivalents. To ensure proper conformance, each system shall be used independently of the other. Combining or converting values from the two systems during the compliance verification process is strictly prohibited by the standard.