Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
This specification, designated D3982‑21, covers contact molded “fiberglass” ducts intended for handling corrosive fumes and process gases. It emphasizes strength and corrosion resistance for operations exceeding 180 °F (82.2 °C). Ducts are designed for pressures up to 65 psig (34.5 Pa), with inch‑pound units regarded as standard. The standard does not cover resin selection for specific chemical environments and is limited to contact‑molded construction using hand layup or spray‑up methods.
| 🟦 Parameter | 📏 Value | 🎯 Unit |
|---|---|---|
| Maximum Design Pressure | 65 | psig |
| Temperature Threshold for Special Attention | 180 | °F |
| Equivalent SI Temperature | 82.2 | °C |
The construction material must be fiberglass with a qualified resin matrix system, such as polyester or vinyl ester, reinforced in accordance with Specification C582. Contact molding methods include “hand layup” and “spray up.” Calculated thickness follows the standard laminate composition tables for Types I and II in Specification C582. Quality is assessed through standardized test methods that verify mechanical and chemical properties.
| 🟦 Test Method | 📏 Standard | 🎯 Purpose |
|---|---|---|
| Barcol Hardness | D2583 | Indentation hardness of rigid plastics |
| Ignition Loss | D2584 | Cured reinforced resin content |
| Chemical Resistance | C581 | Determining chemical resistance for liquid service |
Installation must comply with NFPA 91 for blower and exhaust systems. Users are responsible for establishing safety practices and adhering to regulatory limitations. This standard references terminology from Terminologies D883 and F412. It does not purport to address all safety concerns; users must evaluate and determine appropriate safety and health practices before use.
Ducts are covered up to a design pressure of 65 psig (34.5 Pa).
Permitted resin systems include polyester, vinyl ester, or other qualified resin‑matrix systems meeting Specification C582.
Quality is verified using test methods such as Barcol hardness (D2583), ignition loss (D2584), and chemical resistance (C581).
No known ISO equivalent exists for ASTM D3982‑21.