Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
The open-flame carbon arc exposure apparatus with daylight filters is used for accelerated weathering of pressure-sensitive tapes, conforming to Practices G151 and G152. Specimens are mounted on rigid panels of Type 302 or 304 stainless steel per Specification A666, with a bright annealed finish. Panel dimensions are approximately 75 mm by 225 mm (3 in. by 9 in.).
Exposure must follow G151 and G152 procedures. Duration is based on material specification or agreement. Condition specimens per Practice G147 before testing. Consistent operation is critical for reproducibility within the accepted limits of temperature and humidity.
Results are not equivalent to natural weathering without established correlation. This practice is intended for comparative testing and quality assurance. Variations in operating conditions can affect outcomes, so strict adherence to G151 and G152 is required.
| 🟦 Component | 📏 Requirement |
|---|---|
| Light Source | Open-flame carbon arc with daylight filters |
| Panel Material | Type 302 or 304 stainless steel (A666) |
| Panel Dimensions | 75 mm × 225 mm (3 in. × 9 in.) |
| Panel Finish | Bright annealed |
| Governing Standards | G151 and G152 |