D2882-00 – Standard Test Method Technical Guide

⚙️ Test Procedure and Conditions

This test method, ASTM D2882-00, involves circulating 18.9 ± 0.5 L of hydraulic fluid through a Vickers vane pump for 100 hours at 1200 ± 60 r/min and 13.8 ± 0.3 MPa (2000 ± 40 psi). Fluid temperature at the pump inlet is maintained at 66 ± 3°C for water-containing fluids and petroleum/synthetic fluids of ISO Grade 46 or lighter, or at 80 ± 3°C for other fluids.

🟦 Parameter📏 Specification
Test Duration100 hours
Pump Speed1200 ± 60 r/min
Pump Outlet Pressure13.8 ± 0.3 MPa (2000 ± 40 psi)
Fluid Volume18.9 ± 0.5 L (5 ± 0.13 gal)
Fluid Temperature for Water-Containing Fluids66 ± 3°C (150 ± 5°F)
Fluid Temperature for Other Fluids80 ± 3°C (175 ± 5°F)
🛡️ The fluid volume has been standardized to improve reproducibility as per Note 1 of the standard.

📊 Key Measured Parameters

The wear characteristics are indicated by the total mass loss from the cam ring and the twelve vanes. Additionally, fluid cleanliness levels before and after the test, and initial and final flow rates are reported. Fluid contamination is coded according to ISO 4406.

🛠️ Apparatus and Setup

The test system consists of a 1200 rpm AC motor (minimum 11 kW), a rigid test stand, and a rotary vane pump. The pump must be a Vickers 104C or 105C cartridge type, rated at 28.4 L/min at 1200 r/min with ISO Grade 32 fluid. No modifications to the pump housing are permitted. The total test fluid quantity required is 26.5 L (7 gal).

🟦 Component📐 Specification
Motor Power11 kW (15 hp) minimum
Pump TypeVickers 104C or 105C
Rated Flow28.4 L/min (7.5 gal/min) at 1200 r/min
Maximum Rated Pressure6.9 MPa (1000 psi) – operated at 13.8 MPa (2000 psi) for test
⚠️ The test pump is rated at 6.9 MPa (1000 psi) but is operated at 13.8 MPa (2000 psi). A protective shield around the pump is recommended.

❓ Frequently Asked Questions

🔍 What is the purpose of this test method?

This test method is used to indicate the wear characteristics of petroleum and non-petroleum hydraulic fluids operating in a constant volume vane pump.

💡 How is wear measured?

Wear is determined by the total mass loss of the cam ring and twelve vanes after the 100-hour test.

⚡ What are the key test conditions?

The pump operates at 1200 r/min and 13.8 MPa, with fluid temperature at 66°C or 80°C depending on fluid type.

📌 What safety measure is required?

A protective shield is recommended around the pump due to operation at twice its rated pressure.