Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
ASTM D2852-16 covers the requirements for styrene-rubber (SR) plastic drain pipe and fittings intended for nonpressure underground drainage. This specification applies specifically to plain-end and bell-end components in sizes 2 through 6 in.
As detailed in Section 4, the products are designed for critical drainage applications outside building limits, including:
The standard emphasizes the necessity of dimensional stability, resistance to aging, and strong, tight joints for reliable long-term service.
Pipe and fittings must be manufactured from styrene-rubber (SR) plastics. The specification mandates rigorous test methods to verify material and product performance. These include the Izod Pendulum Impact Resistance (D256), Tensile Properties (D638), and external loading characteristics via Parallel-Plate Loading (D2412).
Impact resistance is critically evaluated using Test Method D2444 (Falling Weight/Tup). Dimensional tolerances are strictly verified per Test Method D2122. For system integrity, joints must be assembled using solvent cements conforming to Specification D3122.
| 🟦 Required Property | 📏 ASTM Test Method | 📐 Applicable Pipe Sizes |
|---|---|---|
| Dimensions & Tolerances | D2122 | 2 – 6 in. |
| Impact Resistance | D2444 (Tup Test) | 2 – 6 in. |
| Load-Deflection / Stiffness | D2412 (Parallel Plate) | 2 – 6 in. |
| Deflection Temperature | D648 | 2 – 6 in. |
Proper installation is critical to the performance of SR drainage systems. Section 4.2 explicitly states that pipe must be installed in accordance with Practice D2321 for underground thermoplastic pipe installations. The requirement for “strong tight joints” dictates the use of approved solvent cements (D3122) for plain-end joints or factory-fabricated bell ends to maintain system watertightness under soil loads.
| 🎯 Intended Application | ⚡ Key Design Feature |
|---|---|
| 📍 House Connection to Septic Tank | Resistance to aging, deflection, and ground movement |
| 🌧️ Foundation & Storm Drainage | Dimensional stability and stiffness under external soil loads |
| 🔗 Joint Assembly | Solvent cements per D3122 or factory bell-end tightness |
🔍 What is the intended scope of ASTM D2852-16?
This standard covers the specifications for styrene-rubber (SR) plastic drain pipe and fittings in sizes 2 through 6 inches, intended for nonpressure underground drainage, such as sewage and liquid waste drainage outside building limits.
💡 What specific test methods are referenced for quality control?
Key test methods include D2122 for dimensional verification, D2412 for external loading characteristics (parallel-plate loading), D2444 for impact resistance (falling tup weight), and D3122 for solvent cements used in joint assembly.
⚡ Does this standard apply to pressurized drainage systems?
No. Section 4 explicitly states that the pipe and fittings described are suitable for “nonpressure underground drainage” applications only, such as gravity-flow sewer and storm drainage connections.
📌 How should the pipe be installed to meet the standard?
Section 4.2 dictates that the piping system must be installed in accordance with Practice D2321, which covers the underground installation of thermoplastic pipe for sewers and other gravity-flow applications.