Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
ASTM D2665-24 is an American National Standard that specifies requirements for poly(vinyl chloride) (PVC) plastic drain, waste, and vent (DWV) pipe and fittings. It covers materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, and solvent cement properties. The standard also includes marking guidelines and references installation procedures in the appendix. It is issued under the fixed designation D2665 and was last approved in 2024.
The scope of D2665-24 defines requirements for PVC DWV pipe and fittings, excluding plastics that do not meet material specifications in Section 5. Materials must comply with Classification System D1784 for rigid PVC compounds. Dimensions and tolerances are measured per Test Method D2122, pipe stiffness and crush resistance via Test Method D2412, impact resistance by Practice D2444, and solvent cement per Specification D2564. Values are standard in inch-pound units.
Testing is integral to this specification. Dimensions are determined using Test Method D2122. External loading characteristics, including pipe stiffness and crush resistance, are evaluated with Test Method D2412 under parallel-plate loading. Impact resistance is assessed by means of a falling tup per Practice D2444. Solvent cement joints must conform to Specification D2564. Conditioning of specimens follows Practice D618 to ensure consistent test results.
| 🟦 Requirement | 📏 Test Method | 📐 ASTM Reference |
|---|---|---|
| Dimensions and Tolerances | Test Method D2122 | D2122 |
| Pipe Stiffness & Crush Resistance | Test Method D2412 | D2412 |
| Impact Resistance | Practice D2444 | D2444 |
| Solvent Cement | Specification D2564 | D2564 |
This specification references several ASTM standards for testing, classification, and terminology. Compliance with these documents is essential for conformance. Key references include D1784 for material classification, D3311 for fitting patterns, and F412 for terminology. The appendix provides installation guidance. The table below lists all primary referenced standards.
| 🔗 Standard | 📄 Description |
|---|---|
| D618 | Practice for Conditioning Plastics for Testing |
| D1784 | Classification System for Rigid PVC Compounds |
| D2122 | Test Method for Dimensions of Thermoplastic Pipe and Fittings |
| D2412 | Test Method for External Loading Characteristics by Parallel-Plate |
| D2444 | Practice for Impact Resistance by Tup (Falling Weight) |
| D2564 | Specification for Solvent Cements for PVC Piping Systems |
| D3311 | Specification for DWV Plastic Fittings Patterns |
| F402 | Practice for Safe Handling of Solvent Cements, Primers, and Cleaners |
| F412 | Terminology Relating to Plastic Piping Systems |
| F1498 | Specification for Taper Pipe Threads for Thermoplastic Pipe and Fittings |
| F1866 | Specification for PVC Schedule 40 DWV Fabricated Fittings |
| F2135 | Specification for Molded DWV Short-Pattern Fittings |
It specifies requirements for materials, dimensions, pipe stiffness, crush resistance, impact resistance, and solvent cement for PVC DWV pipe and fittings, with marking included.
Dimensions are determined using Test Method D2122, which provides procedures for measuring thermoplastic pipe and fittings to ensure tolerances.
The standard references Practice F402 for safe handling of solvent cements and emphasizes that users must establish safety, health, and environmental practices.
Material requirements align with Classification System D1784 for rigid PVC compounds, ensuring consistent material quality and performance.