BS EN ISO 22282 — Geotechnical Investigation and Testing: Geohydraulic Testing

A Six-Part Series of Field Test Methods for Hydrogeological Parameters
⚠️ Part of the source material for this series consists of scanned documents. Technical content for scanned parts (Parts 4–6) is written from publicly available domain knowledge and general hydrogeological engineering practice; always verify against the official BSI edition.

💧 BS EN ISO 22282 is the standard series for geohydraulic testing within geotechnical investigation and testing. Geohydraulic tests control the head and flow in boreholes, wells or trial pits to determine the permeability, water-yielding capacity, groundwater level and seepage characteristics of soil and rock, providing quantitative input for foundation-pit dewatering design, dam-foundation seepage evaluation, groundwater-environment impact assessment, and tunnel/mine water-inflow prediction. Adopted from ISO 22282 through CEN as EN ISO 22282 and implemented in the UK as British Standards (e.g., BS EN ISO 22282-1:2012), the series standardises and makes comparable the hydrogeological testing methods that previously lay scattered across national codes.

1. Overview of the Series 📌

Different objectives and ground conditions call for different methods: open-system permeability tests suit permeability testing in borehole sections; closed-system (double-packer) tests measure permeability within isolated borehole intervals; water pressure tests in rock (Lugeon-type) evaluate fracture permeability; pumping tests determine aquifer parameters and yield; infiltrometer tests suit shallow-surface infiltration characteristics. The BS EN ISO 22282 series is organised as “general rules + method-specific parts”: Part 1 general rules; Part 2 water permeability tests in a borehole using open systems; Part 3 water pressure tests in rock; Part 4 pumping tests; Part 5 infiltrometer tests; Part 6 water permeability tests in a borehole using closed systems. Each part defines applicability, equipment, procedure, data processing and result presentation.

💡 Key to method selection: first define the target parameter (permeability coefficient, transmissivity, storativity, yield), then choose open-system, closed-system or pumping tests according to ground type (soil/rock), water-level conditions and borehole structure — avoiding “method mismatch leading to distorted parameters”.

2. Structure and Part-by-Part Overview 📋

StandardPart SubjectPrinciple and Application
BS EN ISO 22282-1General rulesTerminology, test design, data recording and reporting framework
BS EN ISO 22282-2Water permeability tests in a borehole using open systemsConstant/falling-head injection tests in borehole sections; permeability
BS EN ISO 22282-3Water pressure tests in rockWater-pressure (Lugeon-type) tests evaluating rock fracture permeability
BS EN ISO 22282-4Pumping testsSteady/unsteady pumping; transmissivity and storativity (per domain knowledge)
BS EN ISO 22282-5Infiltrometer testsSurface infiltration rate / permeability of shallow soil (per domain knowledge)
BS EN ISO 22282-6Water permeability tests in a borehole using closed systemsDouble-packer isolated-interval permeability tests (per domain knowledge)

3. Key Technical Requirements 🔧

3.1 Test design and head control

Permeability tests centre on accurately controlling the head difference across the test section and measuring the change of flow with time. The standard specifies test-section length, packer position, injection/withdrawal rates and stability criteria; open-system tests account for the water-level changes in the borehole and its surroundings, while closed-system tests isolate the target interval with double packers to reduce interference from non-target strata.

3.2 Data processing and conversion

According to the boundary conditions (constant/falling head, radial/spherical flow), the corresponding formulas convert to permeability coefficient, transmissivity and other parameters; rock water-pressure tests grade pressure-flow relationships (e.g., Lugeon units) to evaluate groutability and permeability grade of fractured rock. Pumping tests derive parameters from drawdown-time curves by unsteady-flow theory.

🚨 The accuracy of head observation and flow measurement directly controls the permeability result: ending the test before equilibrium, poor packer sealing or failing to record groundwater-level changes distort the data, misleading dewatering design and seepage evaluation.

4. Engineering Practice and Applications 🛠️

  • 🔍 Foundation-pit dewatering: determine aquifer parameters from pumping and permeability tests; calculate well count, spacing and drawdown.
  • 🔧 Dam-foundation and slope seepage control: use rock water-pressure tests to evaluate foundation permeability and guide curtain-grouting design and seepage treatment.
  • 📊 Environmental impact assessment: obtain groundwater-flow and recharge parameters to assess the impact of dewatering/recharge on the surrounding environment.
  • 📋 Tunnel and mine water-inflow prediction: estimate inflow from borehole test results, supporting drainage-system design and safe construction.

5. Frequently Asked Questions ❓

❓ Q: What is the difference between open- and closed-system permeability tests?
A: Open systems perform injection/bail tests in the open borehole section and infer permeability from in-well head dynamics; closed systems isolate a specific interval with double packers, giving more precise results with less interference from adjacent strata.
❓ Q: What are water-pressure (Lugeon) tests mainly used for?
A: They evaluate the fracture permeability and groutability of rock mass — key input for dam-foundation curtain-grouting design and rock-permeability classification, usually expressed in Lugeon units.
🔍 Q: Why can pumping tests yield transmissivity?
A: By fitting the drawdown in observation wells versus pumping time using unsteady-flow theory (e.g., Theis or Cooper–Jacob approximation), both transmissivity and storativity can be derived.
❓ Q: Can scanned part documents be used directly as hydrogeological-parameter acceptance evidence?
A: No; verify test procedures, equipment and calculation formulas against the official current BSI edition before use.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *