🌫️ BS EN ISO 15848 is the British Standard series on the measurement, testing and qualification of fugitive emissions from industrial valves, developed by ISO/TC 153 (Valves) with CEN/TC 69 (Industrial valves), with UK participation through Technical Committee PSE/18/1. Fugitive emissions are gaseous leaks to the atmosphere through valve seals (stem packing, bonnet gasket), and are a major source of volatile organic compound (VOC) emissions in the petrochemical, chemical and oil & gas industries. The series supersedes the 2006 editions and consists of two parts: Part 1 specifies the classification system and qualification procedures for type testing; Part 2 specifies the production acceptance test of valves.
💡 As environmental regulations (e.g., the EU Industrial Emissions Directive, US EPA leak detection and repair (LDAR) requirements) tighten, low-leakage valves have become mandatory for petrochemical projects. The classification and test framework of BS EN ISO 15848 lets buyers select valves by leakage-performance class and verify conformance.
1. Overview of the Series 📌
Classified under ICS 23.060.01 (Industrial valves in general) and published in June 2015, the series supersedes the 2006 editions. The two parts address the “design qualification” and “serial production” stages respectively: Part 1 determines the fugitive-emissions performance class of a valve design through type testing; Part 2 ensures batch-to-batch consistency through production acceptance testing.
| Standard Number | Title | Stage | Core Content |
| BS EN ISO 15848-1:2015 | Industrial valves — Measurement, test and qualification procedures for fugitive emissions — Part 1: Classification system and qualification procedures for type testing of valves | Design qualification / type testing | Leakage class system, test conditions, number of cycles, acceptance criteria |
| BS EN ISO 15848-2:2015 | Industrial valves — Measurement, test and qualification procedures for fugitive emissions — Part 2: Production acceptance test of valves | Serial production / dispatch | Leakage test requirements and acceptance criteria during production |
⚠️ Type testing (Part 1) proves the fugitive-emissions performance of a particular valve type/design under defined conditions; production acceptance testing (Part 2) verifies the products batch by batch. The two cannot substitute for each other: type testing alone without production acceptance testing cannot guarantee the actual leakage performance of serial products.
2. Structure and Technical Essentials 🔧
Parts 1 and 2 establish a complete fugitive-emissions quality-control chain: first type testing establishes the “design capability”, then production testing ensures the “serial-production level”.
| Comparison | Part 1 — Type Testing | Part 2 — Production Acceptance |
| Object | Valve type/design (representative prototype) | Each or sampled valve in series production |
| Test content | Seal leakage under mechanical, thermal and pressure cycling | Leakage test under production conditions |
| Number of cycles | Multiple cycles per class | Relatively few (within production cycle time) |
| Leakage measurement | Measurement method and instruments per class | Simplified leakage criteria |
| Result use | Determine valve fugitive-emissions class (ISO 15848 classification) | Basis for dispatch acceptance |
3. Key Technical Requirements: Classification and Type Testing 🔬
The classification system of Part 1 is the core of BS EN ISO 15848. Tests use a specified medium (usually helium or methane) at specified temperature and pressure, perform a specified number of operating cycles, and measure the leakage rate at the sealing points (stem seal, bonnet seal) to determine the valve’s leakage class.
- Leakage classes: the Standard defines different leakage-rate classes (e.g., classes A, B, C); the earlier the letter, the lower the permitted leakage rate.
- Test conditions: test medium, pressure, temperature (ambient/high) and number of operating cycles are all performed per the class combination defined by the Standard.
- Cycling and thermal testing: type testing usually includes mechanical cycling, thermal cycling and pressure cycling, simulating service open/close, temperature fluctuation and pressure fluctuation.
- Acceptance criteria: the leakage rate at each measurement point during the test must not exceed the limit for the corresponding class, and the valve must operate normally without significant anomaly.
✅ After successful type testing, the valve design can be marked as conforming to a specific fugitive-emissions class. Purchase contracts should require the manufacturer to provide a type-test report conforming to BS EN ISO 15848-1 and specify the required class and technical conditions.
4. Key Technical Requirements: Production Acceptance Testing 🎯
Part 2 specifies the acceptance test performed during valve production, used to verify that serial-produced valves comply with the fugitive-emissions requirements:
- Scope: the production acceptance test applies to designs that have passed type testing under Part 1, performed on every unit or on a defined sample.
- Test conditions: use the specified test medium and pressure, completed within an acceptable test time, balancing production cycle time and quality control.
- Leakage criteria: production leakage criteria correspond to the type test, ensuring the leakage level of serial products is not worse than the qualified design level.
- Records and marking: production acceptance test results should be recorded and supplied with the product as the basis for dispatch release.
⚠️ The production acceptance test cannot replace type testing: even if all production tests pass, type testing is required to prove the design itself achieves the corresponding fugitive-emissions class. After a change of design, material or seal structure, type testing must be repeated.
5. Engineering Practice and Applications 🛠️
- 🔍 Selection and procurement: in environmental-compliance projects, select valves of the appropriate fugitive-emissions class according to the toxicity of the volatile medium and emission limits, and reference BS EN ISO 15848 in the purchase specification.
- 📊 Installation and maintenance: correct stem-packing tightening, packing replacement and periodic maintenance directly affect actual fugitive-emissions levels; establish a packing maintenance programme.
- 📋 Leak detection and repair (LDAR): after commissioning, conduct a leak detection and repair programme as required by regulations, periodically checking and repairing exceedance points at valve seals.
- 🧪 Typical applications: control of fugitive emissions at stem/bonnet seals in refineries, petrochemical, chemical, gas transmission and pharmaceutical plants handling VOCs and toxic media.
6. Frequently Asked Questions ❓
❓ Q: What is the difference between fugitive emissions and internal valve leakage?
A: Fugitive emissions are external leakage of medium to the atmosphere through stem packing, bonnet gasket and similar seals; internal leakage is flow from the inlet to the outlet side through the sealing surfaces when the valve is closed. The test object and criteria differ and are covered by different standards.
❓ Q: Must Parts 1 and 2 be applied together?
A: Usually yes. Part 1 type testing establishes the design class; Part 2 production acceptance testing ensures serial consistency. Contracts or specifications typically require both.
❓ Q: Why use helium or methane as the test medium?
A: Helium has small molecules, leaks easily and offers high detection sensitivity, making it well suited to proving seal performance; methane approximates actual light hydrocarbon media. The test medium is stated in the class designation and should be matched to the service in engineering.
🔍 Q: Does a low-leakage valve need no maintenance after installation?
A: No. Packing wears and ages with time, temperature and operating cycles, so actual emissions change with service life. Even with a high-class low-leakage valve, periodic detection and maintenance per LDAR requirements are still needed.