🏢 BS EN ISO 10848 is the British Standard series implementing EN ISO 10848, which specifies laboratory methods for measuring the flanking transmission of airborne and impact sound between adjoining rooms — transmission through flanking paths such as external walls, floors, partitions, and their junctions. The series comprises a frame document (Part 1) and application parts (2, 3, 4) and is a key reference for sound-insulation design, component transmission evaluation, and acoustic certification of building products. UK participation was entrusted to the relevant subcommittee of BSI committee EH/1 (Acoustics), with ICS 91.120.20.
💡 Measurements and experience show that when the separating element itself already has high sound insulation, sound still “bypasses” through the surrounding flanking elements into the adjoining room — flanking transmission is often the bottleneck limiting final insulation performance.
1. Series Overview 📌
Flanking transmission is the transfer of sound energy between adjoining rooms through paths other than the separating element — via flanking elements and their junctions. This series provides laboratory methods to quantify the transmission of each flanking path, yielding normalised flanking level differences (or impact sound pressure levels) used to compute the combined insulation of element assemblies and to predict sound performance. Part 1 is the frame document: terminology, measurement facilities, microphone arrangements, data processing, and reporting. Parts 2, 3, and 4 give application details for different element assemblies: Part 2 for light elements where the junction influence is small, Part 3 for light elements where the junction influence is substantial, and Part 4 for junctions containing at least one heavy element.
2. Structure of the Series 🧱
| Part | Year | Subject | Scope |
| BS EN ISO 10848-1 | 2006 | Frame document | Terminology, common measurement and reporting requirements |
| BS EN ISO 10848-2 | 2006 (2007 corrigendum) | Light elements (small junction influence) | Flanking measurement for lightly coupled light elements |
| BS EN ISO 10848-3 | 2006 | Light elements (substantial junction influence) | Measurement for light elements with significant junction coupling |
| BS EN ISO 10848-4 | 2010 (scanned copy) | Junctions with heavy elements | Measurement for junctions containing at least one heavy element |
⚠️ Part 4 of this series is a scanned file. The related discussion in this article is based on public-domain knowledge of the field; clauses and numeric requirements must be taken from the official BSI edition.
3. Key Technical Requirements 🎯
- Principle: generate a steady airborne field or impact source in one room, then isolate each flanking path’s contribution by differential measurement.
- Facility requirements: test rooms, source and receiving rooms, sources (loudspeakers, tapping machines), microphones, and signal processing must meet the relevant acoustic standards.
- Frequency range: results are normally reported in one-third-octave bands over the common sound-insulation rating range.
- Data processing: compute the normalised flanking level difference with reverberation-time correction to remove receiving-room absorption effects.
- Repeatability and reproducibility: interlaboratory statistics are given for measurement-uncertainty assessment.
4. Engineering Practice 🛠️
- Building insulation design and prediction: use flanking data to predict combined insulation of multi-element assemblies.
- Lightweight framing systems: flanking transmission is significant in steel-stud partitions, timber structures, and prefabricated buildings and must be measured and controlled.
- Product development and certification: acoustic performance testing of insulation elements, connectors, and sealing systems.
- Standard compliance: complements the ISO 10140 insulation measurement system for element-assembly evaluation.
5. Frequently Asked Questions ❓
❓ Q: What is flanking transmission and why does it matter?
A: Sound energy reaching the adjoining room via paths other than the separating element — such as external walls, floors, and stud junctions — often becomes the weak link in high-insulation elements and must be considered in both design and measurement.
❓ Q: Why are light and heavy elements measured under different parts?
A: Light elements (e.g. gypsum-board walls) and heavy elements (e.g. concrete walls) couple and transfer energy at junctions differently, so measurement details (positions, clamping, corrections) need separate specification.
❓ Q: How does this series relate to ISO 10140?
A: ISO 10140 specifies direct sound-insulation measurement of the separating element; ISO 10848 measures flanking transmission in addition. Both are needed to evaluate real building insulation performance.
🔍 Q: How should the scanned Part 4 be used?
A: The scan is for understanding junctions with heavy elements. For formal testing and reporting, use the latest official BSI edition and follow laboratory quality-system practice.