BS EN ISO 06647 — Rice — Determination of Amylose Content (Reference Method and Routine Methods)

Part 1: Reference Method (ISO 6647-1:2015) and Part 2: Routine Methods (ISO 6647-2:2015)

🌾 BS EN ISO 6647 specifies methods for determining the amylose content of rice, one of the most important and widely applied chemical indices in rice quality evaluation. Amylose content directly affects the stickiness, mouthfeel, swelling and digestibility of cooked rice, and is a key parameter for rice breeding, paddy procurement, rice milling and trade grading. In the UK the series is implemented under Technical Committee AW/4, “Cereals and pulses”, as the official British adoption of ISO 6647 and EN ISO 6647, classified under ICS 67.060. The series consists of two parts: Part 1 specifies the reference method and Part 2 the routine methods.

💡 Amylose content is the core numerical index that “grades rice”: low-amylose rice (about 2%–12%) cooks soft, sticky and glutinous; high-amylose rice (about 25% and above) is firm, swells a lot and tends to separate; intermediate types fall in between. Trade and breeding often grade rice by amylose content.

1. Scope and General Framework 📌

The series applies to rice, including brown and milled (white) rice, and determines the mass fraction of amylose in the rice starch (on a dry basis). The measurement is based on the iodine—amylose colour reaction: amylose forms a characteristic blue complex with iodine whose absorbance is proportional to the amylose content; the weaker colouration of amylopectin with iodine is corrected appropriately.

  • BS EN ISO 6647-1:2015 (reference method): the definitive method of defatting, gelatinisation, iodine colouration and spectrophotometric measurement, used as the reference for arbitration and calibration.
  • BS EN ISO 6647-2:2015 (routine methods): simplified methods for daily testing, suitable for the rapid measurement of large numbers of samples, with results correlated to the reference method.

Both methods require the rice to be ground to flour, defatted, dispersed and gelatinised, coloured with an iodine reagent, and measured at about 620 nm, with the amylose content calculated from a calibration curve.

2. Series Structure and Technical Highlights 🔢

StandardTitleRoleTypical application
BS EN ISO 6647-1:2015Rice — Determination of amylose content — Part 1: Reference methodArbitration, calibration, research baselineMethod validation, standard-sample certification, dispute arbitration
BS EN ISO 6647-2:2015Part 2: Routine methodsHigh-throughput routine testingBreeding screening, paddy procurement, milling quality control

Part 1 emphasises accuracy and traceability; Part 2 emphasises simplicity and throughput. Both share the same key steps of colouration, defatting and calibration-curve preparation, but Part 2 permits simplification of sample preparation and measurement to shorten the cycle per sample.

⚠️ Amylose content is highly sensitive to test conditions: gelatinisation temperature and time, iodine reagent concentration, colouration time, wavelength and the source of reference material all affect the result. The calibration curve must be established and verified under the same conditions for both methods, or data between laboratories will not be comparable.

3. Test Principle and Key Steps 🎯

The measurement can be summarised as:

  • Sample preparation: crush and sieve the rice to a uniform flour; defat if necessary to remove interference from lipids.
  • Dispersion and gelatinisation: fully gelatinise and disperse the starch under alkaline or heated conditions to give a uniform solution.
  • Iodine colouration: add iodine—potassium iodide reagent; amylose complexes with iodine to form a blue complex.
  • Photometric measurement: measure the absorbance at the characteristic wavelength (about 620 nm).
  • Quantification: interpolate the amylose content from the calibration curve of amylose standards (absorbance against content).
✅ Key quality-control points: ① the calibration curve must be built with rice standards of known amylose content or amylose/amylopectin mixtures; ② run a control sample with each batch and confirm the value is within limits; ③ express results on a dry basis, requiring a simultaneous moisture determination.

4. Result Expression and Data Handling 📊

The result is usually expressed as “amylose content (mass fraction, on a dry basis, %)” to one decimal place. Because the amylose content varies considerably with variety, origin and year, the report should state:

  • Sample information: variety, origin, brown/milled state, milling particle size.
  • Test method: reference or routine (with standard number and edition).
  • Moisture: the moisture result used for dry-basis conversion.
  • Replicate determinations: normally two or more parallel measurements, reporting the mean and repeatability.
🚨 Interference from amylopectin cannot be ignored: varieties differ in amylopectin content and structure, and an insufficiently corrected calibration curve can bias high-amylose samples high or low. Prefer reference materials matched to the sample matrix.

5. Engineering Practice 🛠️

  • 🔍 Rice breeding screening: determine amylose content in early generations to rapidly select lines meeting the target quality.
  • 📊 Paddy procurement and pricing: amylose content is a key criterion for grading and pricing quality paddy, requiring fast high-volume measurement at intake.
  • 📋 Rice milling and quality control: millers blend rice by amylose content to control the palatability and yield of the cooked product.
  • 🔧 Quality research and reference materials: the reference method certifies rice standards, providing a traceable baseline for trade and research.

6. Frequently Asked Questions ❓

❓ Q: Is high or low amylose better?
A: It depends on the use. Sushi and soft sticky rice need low to intermediate amylose; fried rice and rice that should separate need higher amylose. Trade grading follows the target market.
❓ Q: Do the reference and routine methods give the same result?
A: The principle is the same but the operating details differ, so a systematic bias may exist. The routine method should be calibrated against the reference method, and the method used should be stated in the report.
❓ Q: Why must the sample be defatted?
A: Lipids in the grain (especially bran lipids) complex with iodine or alter the solution, disturbing the colouration and biasing the absorbance away from the true value. Defatting improves accuracy.
❓ Q: How good is the repeatability?
A: Under strict control, within-laboratory repeatability is usually good (standard deviation within about 0.5%–1%); between laboratories the bias can be larger owing to differences in reference material, instruments and operators, so periodic verification with reference samples is essential.
❓ Q: Is the series limited to Asian rice?
A: No. It applies to all rice (indica, japonica, glutinous and others), provided the sample is a rice matrix.
🔒