š¬ BS EN ISO 06507 is the British Standard series that adopts the European Standard EN ISO 6507, identical to ISO 6507, covering the Vickers hardness test for metallic materials. The family consists of four parts: the test method (Part 1), verification and calibration of testing machines (Part 2), calibration of reference blocks (Part 3), and tables of hardness values (Part 4). It is one of the most widely applied indentation hardness standards in mechanical testing of metals, prepared in the UK by subcommittee ISE/NFE/4/5 (Indentation hardness testing) of BSI technical committee ISE/NFE/4, with ICS 77.040.10.
š” Vickers hardness offers a continuous scale, a small indentation, and applicability to nearly all metallic materials, making it the accepted benchmark for heat-treatment quality, material acceptance, and process control.
1. Series Overview š
The Vickers test uses a square-based diamond pyramid indenter (with an angle of 136° between opposite faces) pressed into the specimen surface; hardness is calculated from the arithmetic mean of the two diagonals of the indentation. Its key advantage is that the test force can be chosen over a very wide range ā from micro-Vickers through macro-Vickers ā and the resulting hardness values are consistent and largely independent of indentation depth, which suits thin parts, hardened layers, coatings, and weld heat-affected zones.
The present series supersedes the earlier BS EN ISO 6507-1/2/3:1998 editions (now withdrawn), with the current parts published around 2005 and maintained since. It is among the most frequently cited hardness references in material acceptance for European pressure equipment, machinery construction, and aerospace applications.
2. Structure of the Series and Technical Highlights š§±
| Part | Year | English Title | Core Content |
| BS EN ISO 06507-1 | 2005 (2006) | Test method | Test-force range, specimen requirements, indentation measurement, calculation and reporting |
| BS EN ISO 06507-2 | 2005 | Verification and calibration of testing machines | Direct and indirect verification, force calibration, indenter and measuring-system checks |
| BS EN ISO 06507-3 | 2005 | Calibration of reference blocks | Uniformity, calibration procedure and acceptance criteria for reference blocks |
| BS EN ISO 06507-4 | 2005 (2006) | Tables of hardness values | Correspondence tables of hardness versus diagonal length and test force |
ā ļø Part 4 of this series is a scanned file (image-scan copy). The related discussion in this article is based on public-domain knowledge of the standard system; numeric data must be taken from the official BSI edition.
3. Core Requirements of the Test Method šÆ
Part 1 (test method) is the most frequently used document. Its key requirements include:
- Test force: nominal forces from about 0.098 N (micro-Vickers) up to about 980.7 N (macro-Vickers) ā e.g. HV0.01 to HV100 ā each with specified tolerances and typical applications.
- Specimen preparation: the surface must be smooth and clean, the test surface perpendicular to the indenter axis; thin sheets and wires require stable support to prevent movement or bending during testing.
- Testing procedure: apply the force smoothly and without impact, hold it for the specified dwell time (typically 10 s to 15 s), then release. The UK subcommittee notes that subclause 7.4 is ambiguous and advises bringing the indenter close to the surface without contact before operating the machine.
- Measurement and calculation: measure both diagonals d1 and d2, take the mean d, and compute HV = constant à F / d², usually reporting three significant figures.
- Reporting: e.g. 640 HV30 denotes a Vickers hardness of 640 under a test force of about 294 N; the symbol, value, and force condition must be stated.
4. Machine Verification and Reference Block Calibration š§
Part 2 defines both direct verification (checking test force, indenter geometry, and measuring system individually) and indirect verification (checking overall machine accuracy with standard hardness blocks), together with recommendations for periodic verification and routine checks. Part 3 specifies the manufacture, uniformity, and calibration of reference hardness blocks; each block must be calibrated at its nominated area with stated traceability and uncertainty.
Together they establish a complete metrological traceability chain ā national primary standard ā calibrated reference blocks ā working hardness blocks ā testing machines ā production results ā supporting reproducibility and mutual recognition of hardness data across laboratories.
ā
Maintaining a systematic calibration log and performing routine checks with reference blocks is the most effective way to keep Vickers hardness data stable and reliable in the long term.
5. Engineering Practice š ļø
- Heat-treatment quality: micro-Vickers indentation profiles are the standard method for case depth and hardened-layer gradient analysis.
- Material acceptance: testing can be performed directly on finished or semi-finished parts without destructive sampling.
- Weld evaluation: micro-hardness of weld metal and heat-affected zones indicates cold-cracking susceptibility and microstructural state.
- Coatings and thin films: micro- and nano-hardness techniques evaluate coating hardness and interface behaviour.
6. Frequently Asked Questions ā
ā Q: Can Vickers values be converted to Brinell or Rockwell?
A: The three tests use different principles, and exact conversion is not recommended. Conversion tables give only rough estimates; for formal acceptance, test with each method according to its own standard, or use a validated conversion and state it in the report.
ā Q: Why must both indentation diagonals be measured?
A: Averaging the two diagonals partially compensates for lack of perpendicularity and material anisotropy, improving the representativeness of the hardness value.
ā Q: Does dwell time affect the result materially?
A: Yes. Too short a dwell may not allow creep stabilization; too long a dwell enlarges the indentation, especially in soft or high-temperature materials. Follow the standard (typically 10 s to 15 s) and record the time.
š Q: How is the Part 4 hardness-value table used?