Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
🎨 BS EN ISO 6504 is the British Standards Institution (BSI) implementation of the European Standard EN ISO 6504, corresponding to the international ISO 6504 series on paint test methods, with the subject “paints and varnishes — determination of hiding power”. The series has several parts; this batch covers two: Part 1 is the “Kubelka-Munk method for white and light-coloured paints” and Part 3 is the “determination of contrast ratio of light-coloured paints at a fixed spreading rate”. In the UK it is prepared under Technical Committee STI/10 (Test methods for paints), and is incorporated into the British BS 3900-D series (corresponding to methods BS 3900-D7 and BS 3900-D11 respectively), falling under ICS 87.040 (Paints and varnishes). Hiding power (coverage) is a core indicator of a coating’s ability to cover the substrate colour, directly affecting paint consumption, cost and coating quality.
Hiding power is defined as the ability of a paint to cover the substrate so that its surface colour no longer shows through, usually expressed as contrast ratio (reflectance on black / reflectance on white) or hiding rate (area covered per unit of application). Part 1 of the BS EN ISO 6504 series uses the Kubelka-Munk theory, measuring reflectances on black/white substrates and using scattering and absorption coefficients to calculate the minimum spreading rate required to reach a specified degree of hiding; Part 3 directly measures the reflectance ratio (contrast ratio) of light-coloured paints on black and white substrates at a fixed spreading rate for quick evaluation.
| Part | Year | Subject | UK Method Corresponds | Measurement Approach |
|---|---|---|---|---|
| BS EN ISO 6504-1 | 2006 (2007 renumbered) | White and light-coloured paints — Kubelka-Munk method | BS 3900-D7 | Theoretically calculate minimum spreading rate for specified hiding |
| BS EN ISO 6504-3 | 2007 | Contrast ratio of light-coloured paints at a fixed spreading rate | BS 3900-D11 | Directly measure black/white reflectance ratio (contrast ratio) |
Part 1 (2006, corresponding to ISO 6504-1:1983, renumbered as BS EN ISO 6504-1:2006 in February 2007) uses the Kubelka-Munk method; Part 3 (2007, corresponding to ISO 6504-3:2006) replaced BS 3900-D11:1998. The two parts evaluate hiding power from “theoretical minimum spreading rate” and “contrast ratio at fixed spreading rate” respectively.
The paint is applied at a controlled rate onto a standard black-and-white chart (or black/white substrates) with controlled film thickness and spreading rate; after drying, the reflectance of the film is measured. The standard specifies application method, drying conditions and film-thickness measurement.
By measuring reflectance of films of different thickness (or spreading rates) on black and white substrates, the Kubelka-Munk equation is used to solve scattering and absorption coefficients, and then to calculate the minimum spreading rate or film thickness required to reach a specified contrast ratio (e.g. 0.98), giving the hiding rate.
At a specified fixed spreading rate, the reflectances of the film on black and white substrates are measured; their ratio is the contrast ratio. The closer the contrast ratio is to 1, the stronger the hiding power. This method is simple and suitable for rapid quality control.
Results are expressed as contrast ratio (0–1) or hiding rate (area per unit application); the report should state application method, spreading rate, drying conditions and measurement geometry (e.g. d/8 or d/0). For non-white or non-light-coloured paints the standard may not apply; other methods should be used.