BS EN ISO 00717 — Rating of Sound Insulation in Buildings Standard Series

Acoustics — Rating of Sound Insulation in Buildings and of Building Elements — Airborne and Impact Sound Insulation (ISO 717 series)

🔊 BS EN ISO 00717 (i.e. BS EN ISO 717) is the British adoption of the European standard EN ISO 717, identical to the ISO 717 series, which specifies methods for rating the sound insulation of buildings and of building elements. Building sound insulation is a key indicator of acoustic comfort in dwellings and workplaces, involving airborne sound insulation and impact sound insulation of floors, walls, doors, and windows. The ISO 717 series converts frequency-dependent insulation curves (measured, for example, per the ISO 10140 series) into single-number rating quantities and spectrum adaptation terms for engineering use, simplifying the comparison, grading, and acceptance of insulation performance. The series was prepared by ISO/TC 43 (Acoustics) in cooperation with CEN/TC 126 (Acoustic properties of building elements and of buildings).

💡 The core of insulation rating is compressing “a curve varying with frequency” into “a single number” (such as Rw, Lw). ISO 717 specifies this compression method and the reference curves, allowing direct comparison of insulation performance between different elements.

1. Positioning and Scope 📌

This series applies to the insulation rating of building elements (walls, floors, doors, windows) and whole buildings. It is based on insulation quantities measured in the laboratory or on site (such as airborne sound reduction index R, normalized impact sound pressure level Ln), and gives single-number rating quantities by fitting reference curves. The standard also specifies spectrum adaptation terms to account for the influence of different sound sources (such as road traffic and living noise) on insulation performance.

Two parts are included in this batch:

  • BS EN ISO 717-1:2013 — Part 1: Airborne sound insulation, specifying single-number quantities (such as Rw, Rw+C, Rw+Ctr).
  • BS EN ISO 717-2:2013 — Part 2: Impact sound insulation, specifying single-number quantities (such as Lw, L’nT,w).
⚠️ Part 1 evaluates airborne sound (speech, music, traffic transmitted through air); Part 2 evaluates impact sound (sound generated by walking, object impact directly exciting the floor). The two address different objects and cannot replace each other.

2. Series Structure and Technical Highlights 📋

StandardCorresponding ISOMain ContentObject
BS EN ISO 717-1:2013ISO 717-1:2013Airborne sound insulation single-number quantities and spectrum adaptation terms (Rw, C, Ctr)Airborne sound blocking
BS EN ISO 717-2:2013ISO 717-2:2013Impact sound insulation single-number quantities and spectrum adaptation terms (Lw, Ci)Impact sound transmission

2.1 Part 1 — Airborne Sound Insulation

BS EN ISO 717-1 defines the single-number rating quantity for airborne sound insulation. The airborne sound reduction index R curve measured in one-third-octave bands is compared with a reference curve, and the deviations are calculated to obtain the weighted sound reduction index Rw. The standard also defines spectrum adaptation terms C (for noise dominated by mid/high frequencies, e.g. living noise) and Ctr (for noise dominated by low frequencies, e.g. traffic noise), combined into Rw+C, Rw+Ctr and similar quantities to reflect insulation performance more accurately under actual source conditions.

2.2 Part 2 — Impact Sound Insulation

BS EN ISO 717-2 defines the single-number rating quantity for impact sound insulation. A standard tapping machine excites the floor, and the standardized impact sound pressure level Ln measured in the receiving room is compared with a reference curve to obtain the weighted impact sound pressure level Lw (or standardized L’nT,w). The lower the quantity, the better the impact sound insulation of the floor. The standard also specifies spectrum adaptation terms for different impact sources.

💡 For floors, “airborne sound insulation” and “impact sound insulation” are two independent indicators: a high airborne value means good blocking of speech-type airborne sound; a low impact value means good blocking of footstep-type impact sound. Floating floors and resilient underlays improve impact sound insulation.

3. Key Technical Requirements 🔧

3.1 Measurement Frequency Range

Insulation rating is based on insulation curves measured in one-third-octave (or octave) bands, typically from 100 Hz to 3150 Hz (or an extended range). Measurements should follow ISO 10140 (laboratory) or ISO 16283 (field) to ensure data quality.

3.2 Reference-Curve Fitting

The standard provides reference curves and fitting rules: the measured curve is compared with the reference curve, and the reference curve is positioned as high as possible while satisfying deviation requirements, giving the single-number rating quantity. The fitting rules ensure a balanced consideration of insulation performance across frequencies.

3.3 Spectrum Adaptation Terms

The terms C and Ctr reflect the difference between the single-number quantity and the actual insulation for different source spectra. Choose the appropriate term according to the actual source type (road, rail, living, mechanical).

3.4 Result Expression and Grading

Results should state the rating quantity, test method (laboratory/field), and frequency range. Different countries or projects may impose minimum insulation grades; design should verify the single-number quantity against the code requirements.

🚨 Single-number quantities cannot replace specific attention to low-frequency noise. Low-frequency (such as bass, machinery) insulation is often more difficult; if the source is dominated by low frequencies, combine the spectrum adaptation term or use dedicated low-frequency evaluation.

4. Engineering Practice 🛠️

  • 🔍 Performance comparison: compare insulation performance of different elements (walls, doors/windows, floors) with single-number quantities to support selection.
  • 🔧 Design verification: check whether the chosen construction meets the required airborne and impact insulation grades per the code.
  • 📊 Completion acceptance: use field measurements and ISO 717 rating to judge whether whole-building insulation meets specified targets.
  • 📋 Product marking: component suppliers can declare single-number insulation ratings per ISO 717 to support design selection.

5. Frequently Asked Questions ❓

❓ Q: What is the difference between Rw and Rw+Ctr?
A: Rw is the weighted insulation without spectrum adaptation; Rw+Ctr is the rating after accounting for low-frequency-dominated noise (such as traffic). Ctr is negative, so Rw+Ctr is usually lower than Rw.
❓ Q: What does a smaller Lw mean?
A: Lw is the weighted standardized impact sound pressure level; the smaller it is, the better the floor’s impact sound insulation (the weaker the sound transmitted into the room).
❓ Q: Why are spectrum adaptation terms needed?
A: The single-number rating is based on a reference curve, while real source spectra vary. Spectrum adaptation terms bring the spectral influence of different sources (traffic, living, mechanical) into the rating, making results closer to reality.
❓ Q: Why do laboratory and field results differ?
A: On site there are flanking paths, gaps, and structural sound bridges; measured insulation is usually lower than the laboratory value. Therefore evaluation and acceptance should clearly distinguish laboratory or field data.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *