The BS EN 88 series is the UK implementation of a European standard covering pressure regulators and associated safety devices for gas appliances. A pressure regulator (governor) reduces the higher inlet pressure from the gas network and maintains it at the outlet pressure required by the appliance, ensuring stable burner operation under inlet-pressure fluctuation. It is a key component of gas hobs, water heaters and boilers. Part 1 specifies regulators for inlet pressures up to and including 50 kPa, and Part 2 specifies regulators for inlet pressures above 500 mbar up to and including 5 bar.
The core function of a pressure regulator is stabilisation: whatever the upstream pressure fluctuation or downstream demand change, it keeps the outlet pressure near the set value, ensuring a stable gas-air ratio, complete combustion and safety.
1. Scope and Series Structure
| Part | Year | Content |
| BS EN 88-1 | 2011+A1:2016 | Pressure regulators and associated safety devices — Part 1: Pressure regulators for inlet pressures up to and including 50 kPa |
| BS EN 88-2 | 2007 | Pressure regulators and associated safety devices — Part 2: Pressure regulators for inlet pressures above 500 mbar up to and including 5 bar |
Both parts were prepared with UK participation by Technical Committee GSE/22 (safety and control devices for gas and oil burners and gas burning appliances), ICS 23.060.40. Part 1 covers domestic and small-commercial low-pressure regulators; Part 2 covers medium-pressure industrial/commercial regulators, with Part 2 prepared by subcommittee GSE/22/19 (pneumatic air/gas ratio controls and governors).
2. Pressure Regulator Operating Principle and Composition
A diaphragm-type pressure regulator typically comprises:
- Valve body and seat: controls gas flow via valve-plug opening.
- Diaphragm: senses outlet pressure and drives the valve plug.
- Spring: sets the outlet pressure (adjustable via the adjustment mechanism).
- Adjustment mechanism: adjusts spring force to set outlet pressure.
Principle: outlet pressure acts on the diaphragm, balancing the spring force. When outlet pressure falls below the set value, the spring pushes the diaphragm to open the valve and increase flow; when it rises above the set value, the diaphragm compresses the spring and closes the valve to reduce flow, stabilising the outlet pressure near the set value.
The regulator’s stabilisation performance directly affects combustion safety: excessive outlet pressure causes over-firing, lower thermal efficiency and higher CO, while too low pressure causes incomplete combustion; the regulator must meet specified stabilisation accuracy and response characteristics.
3. Construction and Performance Requirements
BS EN 88 specifies construction and performance requirements for pressure regulators, mainly including:
- Outlet pressure range and accuracy: specify rated outlet pressure, stabilisation accuracy and deviation under inlet-pressure fluctuation.
- Flow characteristics: flow capacity at specified pressure drop and inlet pressure.
- Closing function: reliable shut-off at zero flow to prevent leakage (lock-up pressure).
- Gas-tightness: airtightness of body, diaphragm and connections meets requirements.
- Material and durability: diaphragm, spring and valve-seat materials should resist gas and temperature and meet endurance tests.
The standard also specifies mechanical strength, temperature resistance, corrosion resistance and marking requirements.
4. Associated Safety Devices
Pressure regulators often incorporate or are equipped with various safety devices, including:
- Safety shut-off valve: automatically cuts off gas on abnormal pressure (over/under pressure).
- Over/under-pressure protection: prevents outlet pressure exceeding a safe range.
- Strainer/filter: prevents debris entering the valve seat, affecting closing and regulation.
- Breather/relief: diaphragm-chamber breather and relief to prevent abnormal chamber pressure.
The performance requirements of associated safety devices are also specified, ensuring safety under abnormal conditions.
5. Engineering Practice and Applications
- Domestic gas appliances: low-pressure regulators for hobs, water heaters and wall-hung boilers to ensure stable combustion.
- Commercial and industrial: medium-pressure regulators for commercial kitchens, industrial furnaces and similar applications.
- Type testing: conduct stabilisation-accuracy, gas-tightness, endurance and safety-device tests per the standard.
- Installation and maintenance: correct installation direction, leave maintenance space, and periodically check the strainer, diaphragm and closing performance.
Engineering recommendation: select the regulator specification by inlet/outlet pressure, flow and gas type; ensure correct flow direction and maintenance space during installation; periodically check gas-tightness and lock-up pressure, and combine with gas-leak detection to ensure gas safety.
6. Frequently Asked Questions
Q: What is the function of a pressure regulator?
A: It reduces the higher inlet gas pressure and maintains it at the outlet pressure required by the appliance, ensuring stable and safe combustion under inlet-pressure fluctuation and load change.
Q: What is the difference between Parts 1 and 2 of BS EN 88?
A: Part 1 specifies regulators for inlet pressures up to 50 kPa; Part 2 specifies regulators for inlet pressures above 500 mbar up to 5 bar.
Q: How does a diaphragm regulator stabilise pressure?
A: Outlet pressure acts on the diaphragm and balances the spring force; as outlet pressure changes, the diaphragm moves the valve plug to open or close the seat, regulating flow and stabilising outlet pressure.
Q: Why is stabilisation accuracy important?
A: Deviation of outlet pressure from the set value changes the gas-air ratio, causing incomplete combustion, higher CO or lower thermal efficiency, affecting safety and performance.
Q: What safety devices should a regulator have?
A: Commonly a safety shut-off valve, over/under-pressure protection, a strainer and a relief/breather; these automatically shut off or relieve under abnormal conditions to ensure gas safety.