🚢 BS EN 62320 is the British Standards Institution (BSI) adoption of the European Standard EN 62320, identical to the international standard IEC 62320, covering the Automatic Identification System (AIS) used in maritime navigation and radiocommunication. AIS is the ship identification and navigational information exchange system mandated by the International Maritime Organization (IMO) under SOLAS; it automatically exchanges dynamic and static information — name, call sign, position, course and speed — between ships and between ships and shore over dedicated VHF channels. The BS EN 62320 series specifies the shore-based and aid-to-navigation infrastructure of the AIS system — base stations, AtoN stations and repeater stations — covering minimum operational and performance requirements, methods of testing and required test results.
💡 The shipborne (mobile) AIS equipment is covered by other standards such as IEC 62287 and IEC 61993; BS EN 62320 focuses on the fixed/aid-to-navigation infrastructure serving shore monitoring, navigational safety and navigational marks, and together they form the complete AIS system.
1. Scope and Basic Framework 📌
The series is maintained by the UK Technical Committee EPL/80 (Maritime navigation and radiocommunication equipment and systems) and adopts the corresponding IEC standards prepared by IEC TC 80. The series comprises three parts, all classified under ICS 47.020.70 (Maritime navigation and radiocommunication equipment), each addressing a specific class of AIS infrastructure:
| Standard | Subject | Corresponding IEC | Key Content |
| BS EN 62320-1:2015 | AIS Base Stations | IEC 62320-1:2015 | Minimum operational and performance requirements, methods of testing and required test results |
| BS EN 62320-2:2017 | AIS AtoN Stations | IEC 62320-2:2016 | Operational and performance requirements, methods of testing and required test results |
| BS EN 62320-3:2015 | AIS Repeater Stations | IEC 62320-3:2015 | Minimum operational and performance requirements, methods of test and required test results |
⚠️ The parts are independent yet complementary: base stations form the “hub” of the AIS shore network, AtoN stations enable navigational marks (buoys, beacons) to be identified, and repeater stations extend coverage or overcome obstructions. Select the part that matches the actual facility type.
2. Series Structure and Technical Points 🔧
2.1 Part 1: AIS Base Stations
BS EN 62320-1 applies to AIS base stations installed at shore, port or offshore facilities to manage the AIS network. The standard specifies minimum performance in transmit and receive channels, output power, sensitivity, slot allocation (TDMA), data processing and network management, together with the corresponding test methods and acceptance criteria. Base stations must be compatible with shipborne AIS mobile stations, follow the AIS VHF Data Link (VDL) protocol, and correctly manage the time slots reported by mobile stations to avoid collisions and ensure communication quality.
2.2 Part 2: AIS AtoN Stations (Aids to Navigation)
BS EN 62320-2 applies to AIS equipment installed on aids to navigation (buoys, beacons, lighthouses, leading marks, etc.). Such stations act as virtual or real AtoN marks reporting their own position and navigational information to passing vessels, and may also be used for remote telemetry, telecommand and monitoring of the navigation facility. The standard specifies operational and performance requirements, message formats, timing and telemetry/telecommand mechanisms, and the associated test methods and required test results.
2.3 Part 3: AIS Repeater Stations
BS EN 62320-3 applies to repeater stations used to retransmit and relay AIS signals to extend coverage or improve reception in shadowed areas. A repeater receives a signal from one station and retransmits it according to specification; the standard specifies minimum operational and performance requirements, receive/transmit conversion and signal-processing criteria, and test methods with required test results, ensuring the repeater does not introduce unacceptable degradation or false reports.
3. Key Technical Requirements and Performance Criteria 🔍
Across the IEC 62320 parts, the core technical requirements for AIS station equipment can be grouped as follows:
- Frequency and channels: AIS uses dedicated VHF maritime channels (161.975 MHz and 162.025 MHz, i.e. CH 87B and CH 88B); equipment must operate correctly within the specified channel bandwidth and meet adjacent-channel and spurious emission limits.
- Transmit power and receive sensitivity: The standard specifies rated output power (typically of the order of 2 W to 12.5 W) and its tolerance, plus receiver reference sensitivity, dynamic range and immunity to interference, ensuring reliable operation under typical maritime propagation conditions.
- TDMA slot management: AIS uses the self-organizing Time Division Multiple Access (SOTDMA) scheme; shore base stations must correctly maintain slot synchronisation, allocation and release to avoid slot conflicts with adjacent stations or vessels.
- Messages and information content: Equipment must encode and decode dynamic, static and voyage-related information according to AIS message specifications (e.g. Message Type 21 for AtoN reports), ensuring accurate and timely information.
- Environmental adaptation and EMC: Stations must withstand severe maritime and shore environments (temperature, humidity, salt fog, vibration) and meet the relevant electromagnetic compatibility (EMC) requirements.
- Operational monitoring and self-test: Some stations also require fault self-test, alarm and remote-monitoring interfaces for centralised network management.
✅ The series follows the unified framework of “minimum operational and performance requirements + methods of testing + required test results”: the standard does not specify product design but type-test acceptance criteria — a device conforms if, when tested by the prescribed methods, the results satisfy the relevant requirements.
4. Test Methods and Conformity Assessment 🧪
Each part systematically defines type-test items, generally including:
- RF performance tests: measurement of transmit frequency error, output power, spectrum mask, receive sensitivity, adjacent-channel rejection and intermodulation/spurious suppression.
- Protocol and timing tests: verification of TDMA synchronisation, slot allocation, message encoding/decoding, channel switching and network access behaviour.
- Environmental tests: temperature, humidity, salt fog, vibration and shock tests per the applicable environmental standards.
- EMC tests: assessment of radiated emission, conducted emission, radiated immunity and electrostatic discharge.
- Functional and reliability verification: extended operation, self-test and alarm functions, power-loss recovery.
Test results must be recorded and compared item-by-item with the required test results specified in the standard; only when all values meet the specified limits is the equipment deemed to conform to the relevant part.
5. Engineering Practice and Application 🛠️
- 🔍 Vessel Traffic Services (VTS): port and coastal VTS centres rely on AIS base stations for real-time tracking, identification and scheduling of vessels entering and leaving port.
- 🔧 Aids-to-navigation management: installing AtoN stations on buoys, lighthouses and other marks provides vessels with identification and positioning information while returning telemetry/telecommand status of the aids to the authority.
- 📊 Coverage and network planning: in areas with convoluted coastlines, island shadowing or remote seas, repeater stations extend AIS coverage to ensure continuous surveillance of key waters.
- 📋 Compliance and acceptance: procurement and acceptance should require the manufacturer’s type-test report and verify that the equipment meets the “minimum operational and performance requirements” of the relevant BS EN 62320 part.
6. Frequently Asked Questions ❓
❓ Q: How does BS EN 62320 differ from shipborne AIS (e.g. IEC 62287)?
A: BS EN 62320 addresses shore/aid-to-navigation infrastructure (base, AtoN and repeater stations), while shipborne AIS mobile equipment is covered by IEC 62287 and similar standards. Both share the same AIS RF and protocol system, but installation, power supply, monitoring and performance emphases differ.
❓ Q: Is BS EN 62320 mandatory?
A: The standard is a voluntary technical specification, but its content is frequently cited as part of mandatory requirements by port states, classification societies and maritime authorities. When SOLAS and related maritime regulations require AIS equipment to meet defined performance, they typically reference this series as the acceptance criterion.
❓ Q: How does an AtoN station (Part 2) differ from a normal AIS station?
A: AtoN stations are designed specifically for navigational marks, with AtoN messages (e.g. Message Type 21), virtual/real AtoN identifiers, telemetry/telecommand and remote configuration, and often battery/solar power to suit environments without mains electricity such as buoys.
🔍 Q: Does a repeater (Part 3) introduce signal delay or bit errors?
A: The standard specifies receive/transmit conversion, signal processing and retransmission timing, and requires verification by prescribed test methods; a conforming repeater must not introduce delay or errors beyond the allowed range, otherwise selection and installation position should be optimised to avoid this.
❓ Q: How is conformity with BS EN 62320 demonstrated?
A: A qualified test laboratory performs the type tests per the standard’s test methods, compares each result with the “required test results”, and issues a type-test report; procurement checks this report together with the equipment nameplate and type-approval certificate.