BS EN 62246 — Reed Switches Standard Series (Generic Specification and Quality Assessment)

UK implementation of IEC 62246 — Part 1: Generic Specification; Part 1-1: Generic Specification — Quality Assessment

🧲 BS EN 62246 is the British Standard implementation of IEC 62246, maintained by BSI Technical Committee EPL/94 (General purpose relays and reed contact units). The technical content is identical to IEC 62246. The series specifies the generic specification and quality assessment requirements for reed switches (also known as dry-reed or magnetic-reed switches). A reed switch is a sealed switch driven by a magnetic field, containing two (or more) magnetisable reed blades inside a sealed glass capsule. When an external magnetic field (for example from a permanent magnet or a coil) reaches a certain strength, the blades attract and close the circuit; when the field is removed, the blades release and open the circuit. Its characteristics include no mechanical friction, hermetic sealing, long life and fast operation, and it is widely used in proximity switches, security door contacts, relays, level gauges and sensors in automotive and household appliances.

💡 The “sealing” of a reed switch is the key to its reliability: the blades and contacts are sealed inside a glass capsule filled with an inert gas, which isolates them from corrosive gases and dust. The contacts therefore do not readily oxidise, lifetimes can exceed a million operations, and the switch can operate for long periods in humid or sulphurous environments.

1. Overview of the Standard Series 📌

The BS EN 62246 series is maintained by BSI Technical Committee EPL/94 (General purpose relays and reed contact units), with UK experts participating in the work of IEC TC 94 (All-or-nothing electrical relays). The series uses a “generic specification plus sectional specification” structure: Part 1 (2015 edition) is the generic specification for reed switches, superseding the 2011 edition; Part 1-1 (2013 edition) is the quality-assessment section under the generic specification, superseding DD IEC/PAS 62246-2-1:2008. As stated in the standard, compliance with a British Standard does not confer immunity from legal obligations, and users remain responsible for correct application.

Within the relay standard framework, IEC 62246 is related to IEC 61810 (all-or-nothing relays), IEC 60947 and other standards. Although a reed switch is structurally simple, its contact material, magnetic performance, encapsulation process and the evaluation of mechanical/electrical life need a dedicated standard to be unified.

2. Structure and Scope of the Series 🧩

The BS EN 62246 files covered by this article comprise two parts:

Standard numberYearTitleKey content
BS EN 62246-1:20152015Part 1: Generic specificationGeneric requirements, terminology, classification, performance parameters, test methods and inspection rules for reed switches
BS EN 62246-1-1:20132013Part 1-1: Generic specification — Quality assessmentQuality-assessment procedures, quality levels and sampling/inspection requirements for reed switches, used together with EN 62246-1:2011

3. Key Technical Requirements 🔧

3.1 Construction, Materials and Key Parameters

The core of a reed switch consists of two (or more) magnetisable metal blades sealed inside a glass capsule; the contact area of the blades is plated with precious metals (such as ruthenium, rhodium or gold) to reduce contact resistance. Its main electrical parameters include:

  • Pull-in value (AT) and drop-out value: expressed in ampere-turns (A·T), they indicate the magnetic field strength required to operate the switch, and are key for matching coils or magnets.
  • Contact resistance: the resistance between contacts in the closed state, typically tens to hundreds of milliohms.
  • Insulation resistance and withstand voltage: the insulation performance between contacts and between contacts and the housing when the switch is open.
  • Rated load and life: the number of operations achievable under specified voltage/current, divided into low-power, medium-power and dry-circuit load classes.
  • Operating time and release time: reflect the dynamic response of the switch.

3.2 Test Methods and Quality Assessment

Part 1-1 specifies the procedures and requirements for quality assessment, including:

  • Assessment procedure: defines the structure of quality assessment (qualification approval / quality-conformity inspection), and the division of the initial manufacturing stage, tests and inspections.
  • Inspection rules and sampling: sampling plans are determined by AQL (acceptable quality level) and batch size, with lot-by-lot inspection of electrical, mechanical and life parameters.
  • Test grouping: tests are divided into routine inspection, sampling inspection and type tests, with specified test items, sample sizes and acceptance criteria for each group.
  • Quality levels: quality levels are assigned according to the reliability level of the product, providing a selection basis for different applications (consumer, industrial, high-reliability).
⚠️ There is a hysteresis between the pull-in value and the drop-out value of a reed switch. This is both an advantage for immunity to interference and a potential source of misjudgement in magnet design. Quality assessment should strictly check the distribution and consistency of the AT value, to avoid a wide scatter in the pull-in value causing false operation or missed operation of the system.

4. Testing and Assessment Implementation 🧪

Test items for reed switches include contact resistance, pull-in/drop-out value, insulation resistance, withstand voltage, life (mechanical and electrical life), vibration/shock resistance, temperature cycling and seal check. Quality assessment follows the “qualification approval plus quality-conformity” model: first confirm by qualification tests that the design and process meet the requirements, then maintain quality conformity through lot-by-lot and periodic inspection. Life tests are normally carried out at rated load for a specified number of operations, checking the change in contact resistance and the failure mode. For high-reliability applications, screening (for example burn-in and hermeticity checks) is used to remove early failures.

✅ Practical suggestion: in proximity-switch and security-door-contact applications, the relative position, distance and magnetic polarity of the magnet and the reed switch directly determine the reliability of operation. When selecting, match the magnet according to the AT value and allow sufficient magnetic-circuit margin; for high-reliability applications, choose a specification with a narrow AT scatter and rhodium-plated contacts.

5. Engineering Practice 🛠️

  • 🔍 Selection: choose the rated value and quality level according to the load type (dry circuit, inductive, resistive), switching voltage/current, operating temperature and required life.
  • 🔧 Circuit protection: for inductive and capacitive loads, provide RC snubbers, diodes or varistors to suppress arcs and contact sticking.
  • 📊 Installation and layout: avoid strong magnetic interference (for example nearby motors and transformers), select the magnet size and mounting distance appropriately, and prevent false operation.
  • 📋 Reliability management: for critical applications, perform incoming inspection (AT value, contact resistance) and periodic life sampling, and maintain a supplier quality record.

6. Frequently Asked Questions ❓

❓ Q: What is the relationship between BS EN 62246 and IEC 62246?
A: BS EN 62246 is the UK implementation of IEC 62246, also adopted by CENELEC as a European standard. The technical content is identical; the British Standard merely adds a national foreword and similar localisation content.
❓ Q: How are Part 1 and Part 1-1 used together?
A: Part 1 specifies the generic specification of reed switches (performance requirements and test methods); Part 1-1 specifies the quality-assessment procedures and inspection rules on top of it. Only the two together form a complete product specification and quality-assurance system.
❓ Q: How do reed switches and Hall sensors compare for selection?
A: A reed switch is a mechanical contact type, offering near-zero power consumption, surge immunity and sealed environmental resistance, but has mechanical life and contact bounce. A Hall sensor is solid-state and contactless, with long life, no bounce and the ability to detect magnetic polarity, but consumes more power and costs more. Select on the basis of power, life, immunity and cost.
🔍 Q: Why is a reed switch suitable for harsh environments?
A: Because its contacts are sealed inside a glass capsule filled with inert gas, isolating them from corrosive gases, moisture and dust. The contacts therefore do not readily oxidise, allowing long-term stable operation in humid, sulphurous or dusty environments.
🔒