BS EN 62037 — Passive RF and Microwave Devices Intermodulation Level Measurement Standard Series

Passive RF and microwave devices, intermodulation level measurement

📡 BS EN 62037 is the British Standard series published by BSI as an identical adoption of IEC 62037 for passive intermodulation (PIM) level measurement of passive RF and microwave devices, prepared by UK committee EPL/46 (Cables, wires, waveguides, RF connectors and accessories for communication and signalling). The series specifies general requirements, measuring methods and test arrangements for PIM measurement of coaxial cable assemblies, coaxial connectors and other passive RF/microwave devices. It is a key basis for evaluating the intermodulation performance of passive devices and safeguarding signal quality and spectrum compatibility in mobile communication base stations, satellite communications and radar systems.

💡 Passive intermodulation (PIM) is the spurious mixing product generated when two or more transmit frequency signals pass through non-linear junctions in passive devices (connectors, cables, antennas, filters, etc.), such as metal-oxide interfaces and magnetic hysteresis materials. These products can fall into the receive band and degrade sensitivity — a parameter that must be strictly controlled in high-quality communication systems.

1. Series Overview 📌

The BS EN 62037 series originates from IEC 62037 and replaces the earlier single-part BS EN 62037:2000, splitting passive intermodulation measurement into several parts by device under test and test content. Current parts include BS EN 62037-1 (general requirements and measuring methods), 62037-2 (PIM measurement in coaxial cable assemblies), 62037-3 (PIM measurement in coaxial connectors), and parts -4, -5 and -6 (addressing other passive devices).

Parts 1, 2 and 3 are readable text; parts 4, 5 and 6 are scanned copies. The technical points in this article are based on the readable parts; the scanned parts are summarised in line with public domain knowledge.

⚠️ Parts 4, 5 and 6 are scanned versions; related technical content is summarised in line with public domain knowledge. Always refer to the official BSI/IEC published text for conformity assessment and system design.

2. Series Structure and Technical Points 📚

StandardSubjectCore Content
BS EN 62037-1:2012General requirements and measuring methodsPIM measurement principles, two-tone test signals, measurement system layout and general provisions
BS EN 62037-2:2013PIM in coaxial cable assembliesPIM measuring methods and test fixtures for assembled coaxial cables
BS EN 62037-3:2012PIM in coaxial connectorsPIM measuring methods and fixture requirements for coaxial connectors
BS EN 62037-4:2012Other passive devices (scanned)Intermodulation measurement methods for filters and other passive devices
BS EN 62037-5:2013Antennas and others (scanned)Intermodulation measurement methods for antennas and system level
BS EN 62037-6:2013Supplementary measurements (scanned)Supplementary intermodulation measurement requirements for other specific passive devices

3. Key Technical Requirements 🔧

General Requirements and Measuring Methods (Part 1)

BS EN 62037-1 specifies the general requirements for PIM measurement: a two-tone test method is adopted, in which two equal-amplitude carrier signals at frequencies f₁ and f₂ are combined and fed to the device under test, and the level of third-order intermodulation products (2f₁−f₂, 2f₂−f₁, etc.) is measured with a high-sensitivity receiver. The standard unifies the test signal power, frequency spacing, test arrangement (combiner, filters, load), connection method and calibration, and expresses PIM figures in dBm (absolute level) or dBc (relative to carrier).

Measurement in Coaxial Cable Assemblies (Part 2)

BS EN 62037-2 specifies PIM measuring methods for assembled coaxial cable assemblies (including end connectors), applicable to feeder cables, jumpers and indoor distribution systems of base stations. Measurements must be carried out with the standard tightening torque and clean conditions to exclude the influence of contaminated or loose contact surfaces on the results.

Measurement in Coaxial Connectors (Part 3)

BS EN 62037-3 gives dedicated measuring methods for coaxial connectors, specifying the connector pair and test fixture mating, contact surface treatment and measurement arrangement. Since connectors are a high-incidence location of PIM, their measurement is important guidance for material selection (e.g. silver plating, non-magnetic materials) and manufacturing process control.

✅ PIM measurement is a “low-level, high-sensitivity” measurement: the noise floor of the test system itself must be far below the measured specification, and ambient temperature, humidity and vibration must be strictly controlled to avoid results being affected by environmental spurs and contact state.

4. Engineering Practice 🛠️

  • Base station feeder systems: perform PIM testing on feeders, jumpers and connectors to ensure intermodulation specifications meet operator requirements and avoid uplink sensitivity degradation.
  • Antenna and filter suppliers: use the methods of Parts 4/5 for factory intermodulation testing as a quality acceptance criterion.
  • System integration and acceptance: perform end-to-end PIM testing during base station construction acceptance and investigate intermodulation degradation caused by installation practices (torque, cleanliness, bend radius).
  • Product selection: prefer passive devices with high PIM performance, low magnetic permeability materials and silver-plating processes.

5. Frequently Asked Questions ❓

❓ Q: What is passive intermodulation (PIM)?
A: PIM is the spurious mixing product generated when two or more transmit frequency signals encounter non-linear effects in passive devices; its frequency may fall into the receive band, reducing receive sensitivity and interfering with communication quality.
❓ Q: Why use the two-tone test method?
A: The two-tone test uses two equal-amplitude carriers to simulate actual multi-carrier operation; the resulting third-order products (e.g. 2f₁−f₂) fall closest to the receive band and are the most harmful, making them the standard criterion for PIM evaluation.
❓ Q: How is the PIM figure expressed?
A: Usually in dBm (absolute power of the intermodulation product) or dBc (ratio relative to carrier power); the more negative the better. The specific limit is determined by system design and operator requirements.
❓ Q: Do scanned versions affect use?
A: No — they only indicate the source copy is a scan; the authoritative clauses are those of the official BSI/IEC published text.
🔒