๐ BS EN 61951 is the British Standard series adopted by BSI from the European Standard EN 61951 (identical to IEC 61951), covering portable sealed rechargeable single cells containing alkaline or other non-acid electrolytes. The series is divided by electrochemical system: Part 1 covers nickel-cadmium (Ni-Cd) cells and Part 2 covers nickel-metal hydride (Ni-MH) cells. The standard covers capacity, discharge performance, cycle life, mechanical and environmental tests and safety requirements of portable sealed cylindrical and prismatic single cells, and is a key reference for battery selection and quality inspection in consumer electronics, power tools, emergency lighting, medical devices and other fields.
๐ก “Sealed” means the cell requires no maintenance and emits no gas under normal service conditions, but it is fitted with a pressure-relief device for abnormal conditions such as overcharge; therefore its factory and in-service management differs from that of valve-regulated batteries.
1. Series Overview and Scope ๐
The series is developed by SC 21A (Secondary cells and batteries containing alkaline or other non-acid electrolytes) of IEC TC 21 (Secondary cells and batteries), coordinated in the UK by PEL/21 and Subcommittee PEL/21/1. This batch of British Standards comprises two parts:
- Part 1: Nickel-cadmium (Ni-Cd) (BS EN 61951-1:2014, identical to IEC 61951-1:2013), specifying requirements and tests for portable sealed Ni-Cd single cells, superseding the 2003 edition.
- Part 2: Nickel-metal hydride (Ni-MH) (BS EN 61951-2:2011, identical to IEC 61951-2:2011), specifying requirements and tests for portable sealed Ni-MH single cells, superseding the 2003 edition.
The series is classified under ICS 29.220.30 (Alkaline secondary cells). Part 1 was approved by CENELEC on 19 November 2013 and published in the UK on 30 September 2014; Part 2 was approved by CENELEC on 29 June 2011.
โ ๏ธ Nickel-cadmium cells contain the heavy metal cadmium, which is restricted under EU RoHS/WEEE legislation; Ni-MH cells are the environmentally friendly alternative. Both environmental requirements and performance requirements should be considered in procurement and design.
2. Series Structure and Technical Points ๐
| Standard | Corresponding IEC | Title | Electrochemical System |
| BS EN 61951-1:2014 | IEC 61951-1:2013 | Secondary cells and batteries containing alkaline or other non-acid electrolytes โ Portable sealed rechargeable single cells โ Part 1: Nickel-cadmium | Nickel-cadmium (Ni-Cd) |
| BS EN 61951-2:2011 | IEC 61951-2:2011 | Secondary cells and batteries containing alkaline or other non-acid electrolytes โ Portable sealed rechargeable single cells โ Part 2: Nickel-metal hydride | Nickel-metal hydride (Ni-MH) |
๐ก The two parts have a similar structure: both specify test conditions (temperature, charge/discharge regime), capacity rating methods, performance tests, cycle-life tests, mechanical tests, environmental tests and safety requirements, but the parameters are set according to each electrochemical system.
3. Key Technical Requirements ๐ง
3.1 Capacity and discharge performance
The standard specifies the method for determining rated capacity (Ah/mAh) under standard test conditions (specified temperature, charge regime and discharge current), and evaluates discharge performance at different discharge rates โ including voltage characteristics at high and low rates. Ni-MH cells have a slightly lower discharge-plateau voltage than Ni-Cd cells, but typically offer higher capacity for a similar volume and lower memory effect.
3.2 Cycle life
The standard specifies the cycle-life test method: repeated charge/discharge under specified conditions, evaluating the number of cycles before capacity falls to a defined threshold (typically 60% of rated capacity), as a key durability indicator. Different applications (consumer, industrial) have different cycle-life requirements.
3.3 Mechanical, environmental and safety tests
- Storage test: evaluates capacity retention and recovery under specified storage conditions.
- Mechanical tests: vibration, shock and drop tests to evaluate structural integrity.
- Environmental tests: high/low temperature performance, damp-heat suitability, etc.
- Safety tests: behaviour under abnormal conditions such as overcharge, short circuit and reverse charge, plus marking and labelling requirements.
3.4 Significant technical changes in Part 2
Relative to the 2003 edition, Part 2 (Ni-MH) added new test clauses and updated technical content from Clause 4 onwards, reflecting new developments in Ni-MH cells for consumer and industrial applications and maintaining terminology consistency with other SC 21A standards.
โ
Key point: test results depend closely on test conditions (temperature, charge/discharge rate, voltage limits). When comparing or selecting cells, always note the test method and the clause of this series used, and avoid directly comparing results obtained under different conditions.
4. Engineering Practice ๐ ๏ธ
- ๐ Power tools and household appliances: single-cell quality inspection and supplier evaluation for battery packs in portable power tools, vacuum cleaners, shavers and similar products.
- โ๏ธ Emergency and standby power: capacity and cycle-life verification of batteries for emergency lighting, alarm systems and UPS backup.
- ๐ Medical devices and instruments: charge/discharge characteristics and safety verification for batteries in high-reliability medical and measuring instruments.
- ๐ Procurement and incoming inspection: referencing this series in purchase specifications to standardise capacity ratings, test methods and acceptance criteria.
5. Frequently Asked Questions โ
โ Q: What is the main difference between Ni-Cd and Ni-MH cells?
A: Ni-Cd cells tolerate overcharge/overdischarge better, perform well at low temperature and have long life, but contain cadmium and are environmentally restricted; Ni-MH cells have higher energy density and are cadmium-free, but have higher self-discharge and are more sensitive to overcharge, so charge management must be matched.
โ Q: How is “rated capacity” defined in the standard?
A: Rated capacity is the value nominally declared by the manufacturer under specified test conditions (temperature, charge regime, discharge current and end voltage) and verified by test, with acceptance governed by the tolerances in the standard.
โ Q: How is “end of life” determined in the cycle-life test?
A: Under the charge/discharge regime in the standard, the end of life is reached when capacity falls to the specified percentage of rated capacity (generally 60%); the number of cycles reached is the cycle life.
๐ Q: Does this series apply to battery assemblies or packs?
A: The series addresses single cells. Battery assemblies and packs are covered by the relevant system and safety standards; however, this series is an important basis for pack design and single-cell inspection.