💡 This article is a scanned-version write-up based on public-domain knowledge. BS EN 61158 is the UK-implemented family of fieldbus specifications for industrial communication networks, adopted by BSI from IEC 61158 and used together with the IEC 61784 communication-profile system. This batch contains 81 documents, organised into -1 (overview and guidance), -2 (data-link layer services and protocol), -3-x and -4-x (application layer services and protocols for various fieldbus types), and -5-x and -6-x (application layer service definitions and protocol specifications). It is the technical foundation for interoperability and real-time communication in industrial automation systems (DCS, PLC, field instruments), referenced by mainstream fieldbuses such as PROFIBUS and Foundation Fieldbus.
💡 BS EN 61158 and IEC 61784 are used together: 61158 defines the lower protocol layers (data-link, application), while 61784 defines the “communication profile” — how protocols are combined into an interoperable system configuration.
1. Overview and Scope 📌
BS EN 61158-1:2014 is the series overview and guidance, maintained by BSI Technical Committee AMT/7 (Industrial communications: process measurement and control, including fieldbus), classified under ICS 25.040.40 (industrial process measurement/control), 33.040 (communications) and 35.100.05 (multi-layer applications). It supersedes PD CLC/TR 61158-1:2010 and coordinates the IEC 61158 and IEC 61784 families. The whole 61158 series defines multiple fieldbus “Types” so that field devices from different vendors can exchange data deterministically over a common control network.
The scope covers automation networks in both discrete and process industries: real-time digital communication among sensors, actuators, controllers and HMIs. It does not prescribe specific physical cable selection (partly addressed in -2) but defines data-link and application-layer behaviour.
⚠️ There are many coexisting fieldbus “Types” (Type 1, Type 2 …). Selection must not stop at the 61158 title; the specific type and its companion profile (IEC 61784) must be identified, otherwise devices will not interoperate.
2. Series Composition and Technical Points 🔧
The table below lists the principal structure of the series (based on the real file list in the material).
| Standard | Layer / subject | Edition | Remark |
| BS EN 61158-1 | Overview and guidance | 2014 | Guide to IEC 61158 and 61784 families |
| BS EN 61158-2 | Physical layer services & protocol | 2014 | Defines physical medium and signals |
| BS EN 61158-3-1/-3-2 … | Data-link layer services | 2008/2014 | DL services per fieldbus type (-3-x) |
| BS EN 61158-4-1/-4-2 … | Data-link layer protocol | 2008/2014 | DL protocol per fieldbus type (-4-x) |
| BS EN 61158-5-2/-5-3 … | Application layer service def. | 2008/2014 | AL services per type (-5-x) |
| BS EN 61158-6-2/-6-3 … | Application layer protocol spec. | 2008/2014 | AL protocol per type (-6-x) |
The file list shows that the -3, -4, -5 and -6 layers are each subdivided by type (e.g. -3-1, -3-2, -3-3). The 2008 editions mostly cover earlier types such as Type 1, while the 2014 editions expanded the number of types and sub-types, reflecting the continuing evolution of fieldbus technology.
💡 Common references: PROFIBUS is mainly based on 61158 Type 3; Foundation Fieldbus on Type 1. Developers should locate the specific part by the target bus type.
3. Key Technical Requirements 🔥
Fieldbus specifications focus on determinism, real-time behaviour and interoperability. Key technical elements include:
- Data-link layer (DL): medium access control (MAC), communication scheduling, frame structure, addressing, error detection and retransmission, bus arbitration. Deterministic scheduling is the precondition for real-time control.
- Application layer (AL): object dictionary, variable access, events and alarms, domain upload/download, context management, enabling devices from different vendors to exchange process data with a uniform semantics.
- Communication profile: baud rate, topology, function blocks and device description, enabling plug-and-play interoperability (defined in IEC 61784).
- Real-time performance: periodic process data update (e.g. 1–10 ms) separated from aperiodic parameter access, keeping control loops stable.
- Network management: device commissioning, topology discovery, fault diagnosis, redundancy and online replacement.
- Functional safety extension: some buses support SIL-rated safety communication (e.g. PROFIsafe), interfacing with IEC 61508/62061.
🚨 Fieldbus networks are part of industrial control systems affecting operational safety. Network modifications, baud-rate and topology changes must be performed during shutdown or controlled conditions; misconfiguration can cause process loss of control or communication interruption.
4. Engineering Application 🛠️
- 🔍 Selection flow: define control needs (cycle, node count, distance, functional safety) → choose fieldbus type (e.g. PROFIBUS DP/PA, FF, Ethernet/IP) → reference the corresponding 61158 layer parts + IEC 61784 profile → integrate via device description.
- 📋 Interoperability verification: perform device interoperability testing at system integration, confirming object dictionary, function blocks and timing consistency.
- 🔧 Engineering tools: use GSD/EDS device description files to configure the network and bus analyzers to troubleshoot communication faults.
- ♻️ Version tracking: the 2014 edition greatly expanded types and layers; new projects should prefer 2014, while legacy systems keep their original version for compatibility.
✅ Locking the bus architecture on the dual dimensions of “type + profile” and completing the interoperability matrix at design stage avoids protocol mismatches during field integration.
5. Frequently Asked Questions ❓
❓ Is BS EN 61158 the same as IEC 61158?
Answer: Technically identical. BS EN 61158 is the UK national adoption of IEC 61158; for the UK market the BS EN designation governs.
❓ Why are there so many “Types” in 61158?
Answer: Several fieldbus technologies coexisted historically (PROFIBUS, FF, ControlNet, WorldFIP, etc.). IEC folded them into one framework as “Types” so they can coexist and be referenced at the standards level.
❓ How are specific protocol details confirmed given the “scan” files?
Answer: Most of the 81 documents are scan-based. This article is written from the machine-readable -1/-2/-3-1 forewords combined with public-domain knowledge of IEC 61158; specific protocol details should be taken from the official BSI published version.
❓ What is the relationship between fieldbus and industrial Ethernet (e.g. PROFINET)?
Answer: Traditional fieldbuses (61158 Type 1–Type 20+) are mostly real-time networks over serial/dedicated media; PROFINET and similar industrial Ethernet implement real-time communication over TCP/IP as an upgrade, but still borrow the profile and application-layer concepts.