📐 BS EN 61143 is the UK adoption of the IEC 1143 series (later renumbered IEC 61143), specifying definitions, classification, reference conditions, intrinsic errors, nominal range of use and additional test methods for X-t recorders — self-recording electrical measuring instruments that plot the measured variable (t) against time (X). The series has two parts: Part 1 gives the generic definitions and requirements; Part 2 gives recommended additional test methods. It applies to instruments that produce a continuous graphic record of electrical or non-electrical quantities in industrial process recording, power monitoring and laboratory data acquisition.
BS EN 61143 is structured in two parts covering the basic specification and the test methods:
| Standard | Title | Subject | Adoption |
|---|---|---|---|
| BS EN 61143-1:1994 | Electrical measuring instruments — X-t recorders — Part 1: Definitions and requirements | Definitions and requirements | Identical to IEC 1143-1:1992 (incl. A1:1997) |
| BS EN 61143-2:1994 | Electrical measuring instruments — X-t recorders — Part 2: Recommended additional test methods | Recommended additional test methods | Identical to IEC 1143-2:1992 |
Part 1 covers description, classification and compliance, reference conditions and intrinsic errors, nominal range of use and variations, further electrical and mechanical requirements, constructional requirements, information/markings/symbols, terminal markings and compliance tests. Part 2 adds recommended additional test methods: intrinsic error test, additional error due to zero displacement, mutual influence of multiple measuring circuits, influence of parasitic quantities, and dynamic performance (response time, frequency response range, overshoot).
The standard establishes a rigorous definitional framework. Recorders are classified by recording method, drive method and measuring-circuit type, and the manufacturer must clearly mark reference values, reference ranges and nominal ranges of use. Reference conditions are the set of conditions — with each influence quantity held within a stated tolerance — under which intrinsic error is determined; Table 1 lists these conditions and their test tolerances.
Table 2 defines the limits of the nominal range of use and the corresponding permissible variations. When an influence quantity (ambient temperature, humidity, external magnetic field, supply voltage, etc.) deviates from the reference condition but stays within the nominal range of use, the recorder is allowed an additional variation beyond intrinsic error. Designers must confirm that the combined error of the recorded curve still meets the measurement task under expected site conditions.
| Concept | Meaning | Engineering role |
|---|---|---|
| Reference conditions | Conditions for influence quantities when intrinsic error is fixed | Laboratory calibration basis |
| Intrinsic error | Maximum error under reference conditions | Basic instrument accuracy |
| Nominal range of use | Limits within which influence quantities may deviate | Field applicability boundary |
| Permissible variation | Upper limit of additional error within nominal range | Basis for field error assessment |
Part 2 recommends several additional test methods for a fuller evaluation of recorder performance:
BS EN 61143 is not isolated; it sits with BS EN 61010 (safety of electrical measuring equipment), BS EN 60688 (measuring transducers) and BS EN 61140 (protection against electric shock) in the complete electrical-measurement specification chain. An X-t recorder normally works as a secondary instrument with primary sensors (thermocouples, RTDs, current transformers, pressure transmitters), so its input range, input impedance and overload capability must match the front-end sensor. Part 1 specifies the input circuit, range switching and chart specifications, all to be checked at selection.
In practice recorders are used for continuous monitoring and historical traceability at power plants, substations and chemical plants. Beyond accuracy, pay attention to chart speed, recording bandwidth, chart-drive reliability, pen/printer life and communication interfaces (RS-232, RS-485, analogue output). For long unattended duty, prefer models with data storage and power-loss continuation, and evaluate stability under supply fluctuation and EMI per the standard’s test methods.
| Selection aspect | Focus | Related standard |
|---|---|---|
| Safety | Insulation, contact protection | BS EN 61010 |
| Input matching | Range, impedance, overload | BS EN 60688 |
| Error model | Intrinsic + additional variation | BS EN 61143 |
| Data interface | Digital output, protocol | Enterprise / system spec |
Overall, recorder selection should follow “define the measurement task and site environment, then check the error model, finally verify safety and interface”, combining BS EN 61143 with companion standards to ensure both credible recorded data and long-term site safety and maintenance.