BS EN 61131 — Programmable Controllers (PLC) Standard Series

Programmable Controllers (EN 61131 series, identical to IEC 61131)

🤖 BS EN 61131 is the European Standard series on programmable controllers (PLCs), whose technical content is identical to IEC 61131. PLCs are the core computing devices of industrial automation and process control. The series defines the general information, equipment requirements and tests, programming languages, communications, functional safety, fuzzy control programming and the single-drop digital communication interface (SDCI) for small sensors/actuators. It is the standard family most cited by automation engineers, software engineers and equipment manufacturers. The UK participates through GEL/65 (Measurement and control) and its subcommittee GEL/65/2.

💡 Part 3 (programming languages) is the “common mother tongue” of PLC engineers worldwide: it standardises five languages — Ladder Diagram (LD), Instruction List (IL), Structured Text (ST), Function Block Diagram (FBD) and Sequential Function Chart (SFC) — making code from different PLC brands portable and interchangeable.

1. Overview and Background 📌

The IEC 61131 series was developed by IEC TC 65 (Industrial-process measurement, control and automation), adopted by CENELEC as EN 61131 and published by BSI (for example BS EN 61131-1:2003, BS EN 61131-2:2003, BS EN 61131-3:2013). The series took shape in the 1990s and has been continuously expanded and revised with control technology (programming-language standardisation, functional safety, fuzzy control, industrial-IoT interfaces). The 2013 edition of Part 3 is a compatible extension of the 2003 edition, adding several data types and conversion functions.

⚠️ Parts 5, 6, 7 and 9 of this series exist as scanned copies in the source material; their technical content has been compiled from public-domain knowledge. Refer to the latest official BSI version for programming and safety-related requirements.

2. Structure of the Series 📑

StandardSubjectContent Focus
BS EN 61131-1:2003General informationPLC terms, definitions and general requirements
BS EN 61131-2:2003Equipment requirements and testsElectrical, mechanical, EMC and environmental tests
BS EN 61131-3:2013Programming languagesFive standard programming languages and data types
BS EN 61131-5:2001CommunicationsCommunication requirements between PLC and external devices
BS EN 61131-6:2012Functional safetyFunctional-safety requirements for safety-related controllers
BS EN 61131-7:2001Fuzzy control programmingProgramming specification for fuzzy-control function blocks
BS EN 61131-9:2013Single-drop digital communication interface (SDCI)Communication interface for small sensors/actuators

3. Key Technical Content 🔧

3.1 Equipment Requirements and Tests (Parts 1 and 2)

Part 1 defines PLC terms and general information; Part 2 specifies the electrical, mechanical, environmental and electromagnetic-compatibility requirements and corresponding type tests for PLCs and their external peripherals, including power-supply fluctuations, electrostatic discharge, surges, fast transients, temperature/humidity and vibration, ensuring reliability in harsh industrial environments.

3.2 Programming Languages (Part 3)

Part 3 defines the languages and data structures of PLC programs: Ladder Diagram (LD) for relay-logic thinking, Function Block Diagram (FBD) for signal flow, Instruction List (IL) as assembly-style, Structured Text (ST) as a high-level language, and Sequential Function Chart (SFC) for state-machine description; it also specifies variables, data types, program organisation units (POUs) and the execution-control model — the cornerstone of PLC software portability.

3.3 Communications, Functional Safety and Fuzzy Control (Parts 5, 6, 7)

Part 5 governs communication between the PLC and external systems (such as data exchange with fieldbus and host computers); Part 6 imposes additional requirements on programmable controllers used for safety functions (such as emergency stop, safety interlock) based on the functional-safety concept (referencing IEC 61508); Part 7 provides a programming specification for fuzzy-control function blocks.

3.4 SDCI Interface (Part 9)

Part 9 specifies the single-drop digital communication interface (SDCI) between PLCs and small sensors/actuators — a standardised point-to-point connection at the industrial-IoT edge, supporting parameterisation, diagnostics and bidirectional data exchange.

🚨 Safety reminder: PLCs used for safety functions must have their safety integrity assessed under Part 6 (functional safety); an ordinary PLC cannot directly fulfil emergency-stop or safety-gate SIL/PL tasks — use a certified safety PLC or safety relay in safety circuits.

4. Engineering Practice and Applications 🛠️

  • 🔍 PLC manufacturers: complete type tests and EMC reports per Part 2, and provide a Part 3-compliant programming environment and libraries.
  • 🔧 Automation engineers: write portable programs in the Part 3 standard languages, and interface with host computers and fieldbus per the Part 5 communication specification.
  • 📊 System integrators: in safety-related projects, distinguish ordinary PLCs from safety PLCs and design safety functions per Part 6 and the functional-safety standards.
  • 📋 Equipment acceptance: verify the PLC environmental class, EMC test report and programming-language consistency as acceptance and archiving evidence.

5. Frequently Asked Questions ❓

❓ Q: Can the five programming languages be mixed?
A: Yes. Part 3 allows mixing multiple languages within one program, for example using SFC for flow, FBD for loops and ST for algorithms.
❓ Q: Can an ordinary PLC perform emergency-stop safety functions?
A: Not directly. Safety functions should be assessed per Part 6 and the functional-safety standards (such as IEC 61508, ISO 13849); a safety PLC or safety relay is normally required.
❓ Q: What changed in the 2013 edition of Part 3 versus 2003?
A: The 2013 edition is a compatible extension, mainly adding data types and conversion functions and clarifying existing features, without changing the semantics of existing programs.
🔍 Q: What problem does SDCI (Part 9) solve?
A: It connects small sensors/actuators to controllers in a uniform, low-cost, point-to-point way, supporting parameterisation and diagnostics — an important interface for industrial-IoT edge connection.
🔒