BS EN 61003 — Industrial-Process Control Systems — Instruments with Analogue Inputs and Two- or Multi-Position Outputs Standard Series (Performance Evaluation and Inspection)

Instruments with Analogue Inputs and Two- or Multi-Position Outputs (EN/IEC 61003 Series)

🎛️ BS EN 61003 is the British Standard adopting, identically, the IEC 61003 European standard series for instruments with analogue inputs and two- or multi-position outputs in industrial-process control systems, giving performance evaluation and inspection methods. Developed by IEC/TC 65 (Industrial-process measurement, control and automation), Subcommittee SC 65B (Measurement and control devices), approved by CENELEC as EN 61003, and adopted in the UK by committee GEL/65 and its subcommittee GEL/65/2 (Elements of systems), it covers instruments (e.g. two-position/multi-position controllers, regulating instruments with switching outputs) that convert continuous (analogue) process variables into discrete (switching) outputs. Such instruments are typical devices for threshold alarms, on/off regulation, and interlocking in process control systems.

💡 “Two- or multi-position output” means the instrument compares the analogue input (e.g. temperature, pressure, flow) with a setpoint and outputs two or more discrete states (e.g. on/off), used for two-position control or staged control.

1. Scope and General Framework 📌

The BS EN 61003 series applies to instruments with analogue inputs and two- or multi-position outputs in industrial-process control systems (e.g. two-position controllers, multi-position controllers). The series structure is:

  • Part 1: Methods for evaluating performance: test methods and acceptance criteria for evaluating the performance of such instruments.
  • Part 2: Guidance for inspection and routine testing: guidance for inspection and routine (unit-by-unit) testing.

The documents are BS EN 61003-1:2016 (corresponding to IEC 61003-1:2016, edition 3) and BS EN 61003-2:2016 (corresponding to IEC 61003-2:2016, edition 2). ICS classification is 25.040.40 / 35.240.50.

⚠️ Part 1 and Part 2 are used together: Part 1 defines how to evaluate instrument performance (type/performance tests), while Part 2 gives guidance for inspection and routine (factory) testing; together they ensure instrument quality.

2. Series Composition and Technical Points 🔧

StandardTitleFocusIEC EquivalentStatus
BS EN 61003-1:2016Methods for evaluating performanceControl characteristics, dead band, hysteresis, accuracy, testsIEC 61003-1:2016Current (edition 3)
BS EN 61003-2:2016Guidance for inspection and routine testingFactory inspection, routine test items and decisionIEC 61003-2:2016Current (edition 2)

1. Methods for Evaluating Performance (Part 1)

Part 1 specifies methods for evaluating the performance of instruments with analogue inputs and two- or multi-position outputs:

  • Input/output characteristics: correspondence between the analogue input (e.g. 4–20 mA, 0–10 V, or temperature signal) and the discrete output.
  • Control characteristics: determination of setpoint, switching value, hysteresis (switching differential), and dead band.
  • Accuracy and repeatability: assessment of switching-point accuracy, repeatability, drift, and other performance parameters.
  • Test conditions: evaluation of the effect of environmental conditions, supply influence, and load influence on performance.
  • Dynamic characteristics: output switching time, response time, and interference immunity.

2. Guidance for Inspection and Routine Testing (Part 2)

Part 2 gives guidance for inspection and routine (unit-by-unit) testing of such instruments:

  • Inspection items: checklist of appearance, marking, function, and performance checks.
  • Routine tests: items to be performed on each unit before dispatch (e.g. insulation, withstand voltage, switching function).
  • Decision and records: acceptance criteria and inspection record requirements.
💡 For a two-position controller, the “hysteresis” (switching differential) and “dead band” determine control stability and accuracy: too small causes frequent switching, too large reduces control accuracy — set according to process requirements.

3. Key Technical Requirements 🔬

Key technical requirements for such instruments include:

  • Switching-point accuracy and repeatability: deviation and repeatability of the output operating point relative to the setpoint, affecting control accuracy.
  • Hysteresis (switching differential) and dead band: the hysteresis width between switching points, determining anti-chattering and control accuracy.
  • Input range and output load: input signal range and load capability of the switching output (relay/transistor).
  • Environmental and supply influence: limits on the effect of temperature, humidity, and supply fluctuation on switching characteristics.
  • Insulation and safety: insulation and withstand voltage requirements between input/output/supply.
🚨 Process control instruments directly participate in process safety interlocking. If switching fails or drift exceeds limits, process parameters may go out of control, false alarms may occur, or interlocks may not operate. Perform functional verification before commissioning and calibrate periodically.

4. Engineering Practice and Application 🛠️

  • 🔍 Selection: choose the input signal by process variable type and range, the output type and number by actuator and control strategy, and verify switching accuracy and hysteresis.
  • 🔧 Installation: install instruments in locations meeting environmental and vibration requirements; wire correctly with proper signal shielding and earthing.
  • 📊 Calibration: before commissioning, verify switching point, hysteresis, and accuracy per Part 1, and set protection/interlock parameters.
  • 📋 Maintenance: calibrate and functionally test periodically, record drift trends, and act promptly on out-of-tolerance.

5. Frequently Asked Questions ❓

❓ Q: What is two-position (on/off) control?
A: Two-position control is a simple control mode with only “on/off” output states, e.g. switching off heating above an upper limit and on below a lower limit; multi-position control adds intermediate levels to achieve staged regulation.
🎛️ Q: What is hysteresis (switching differential)?
A: The input difference (hysteresis width) between the on and off switching points of the output. Hysteresis prevents frequent switching due to signal fluctuation, but excessive values reduce control accuracy.
📊 Q: How does the Part 2 routine test differ from the Part 1 performance test?
A: Part 1 performance evaluation is comprehensive type/performance testing; Part 2 routine testing is simplified inspection of each unit before dispatch (e.g. function, insulation, withstand voltage) for production quality assurance.
🔌 Q: Why is switching accuracy important for interlocking?
A: Interlock operation depends on switching-point accuracy; if the switching point drifts or is out of tolerance, the interlock may operate when it should not or fail to operate when required, endangering process and personnel safety — hence periodic verification.
🔒