BS EN 60684 — Flexible Insulating Sleeving Standard Series

Flexible insulating sleeving(IEC 60684 / EN 60684)

🧵 BS EN 60684 is the European (CENELEC EN) and UK (BS) implementation of IEC 60684, “Flexible insulating sleeving”, mirrored by BSI Technical Committee GEL/15 (Solid electrical insulating materials) and subcommittee GEL/15/5 (Flexible insulating sleeving for electrical purposes). Sleeving is the flexible tubular insulator slipped over wires, terminations and harnesses for insulation, mechanical protection, identification and thermal shielding. The series uses Part 2 (methods of test) as the common test base and Part 3-xxx (specifications for individual sleeving types) to cover extruded silicone, extruded polychloroprene, heat-shrinkable, braided glass-fibre, acrylic-coated, PVC-impregnated/coated, low-smoke zero-halogen, flame-retardant and high-temperature sleeving — the authoritative basis for sleeving selection and acceptance in electrical apparatus, automotive harnesses, aerospace and appliances.

📌 Note: the series comprises 17 documents, most scanned copies. Where temperature ratings, bore series and test conditions are discussed, the text is based on public-domain knowledge and marked “扫描版本,依据公开领域知识撰写” (scanned version, written from public-domain knowledge); the authoritative requirements must be taken from the official BSI publication.

💡 EN 60684 follows the same architecture as wire and cable: “Part 2 (test methods) + Part 3 (product specifications)”. Choose the specific Part 3 sheet (e.g. 3-121~124 braided glass fibre) by working temperature, voltage, flame retardancy and environment, then perform acceptance testing per Part 2.

1. Scope and General Framework 📌

Flexible insulating sleeving plays a “small part, big role” in electrical equipment: it prevents conductor abrasion, insulates terminations, bundles harnesses neatly and shields against heat at hot spots. IEC 60684 unifies sleeving products and tests: Part 2 defines tests for dimensions, temperature index, impregnation, voltage (withstand), mechanical (tension, elasticity, bending), burning, chemical and climatic ageing; Part 3 sheets specify, per material and process, the concrete performance requirements of each sleeving type (bore series, wall thickness, colour, grade and test requirements). The series was published from 1995–2002 and continuously revised (e.g. Part 2:2011, 3-116:2011, 3-280:2010+A1:2014), partly superseding the old BS 6893.

Scope: insulation and protection sleeving for motors, transformers, appliances, automotive and rail harnesses, and aerospace equipment — covering extruded, braided, coated and heat-shrinkable products.

2. Series Composition and Technical Points 🔧

The table below lists the main parts of EN 60684 and their Chinese subject descriptions.

PartSubjectTypical edition
EN 60684-2Part 2: Methods of test2011
EN 60684-3-1163-116/117: Extruded polychloroprene, general purpose2011
EN 60684-3-121~1243-121~124: Braided glass fibre (impregnated/coated) sleeving2001
EN 60684-3-2053-205: Heat-shrinkable sleeving (polyolefin general)2011
EN 60684-3-2093-209: Flame-retardant/high-temperature heat-shrinkable2010
EN 60684-3-2143-214: LSZH heat-shrinkable / sleeving2014
EN 60684-3-2163-216: Cross-linked, higher-temperature resistant sleeving2005 + A2:2014
EN 60684-3-2473-247: PVC-type sleeving2011
EN 60684-3-2713-271: Extruded silicone rubber sleeving2011
EN 60684-3-2803-280: Acrylic-coated glass fibre sleeving2010 + A1:2014
EN 60684-3-2813-281: Polyurethane/resin-impregnated braided sleeving2010
EN 60684-3-2823-282: Silicone-resin-impregnated glass fibre sleeving2010
EN 60684-3-2833-283: Flame-retardant braided glass fibre sleeving2011 + A1:2014
EN 60684-3-2843-284: High-temperature (Nomex-type) braided sleeving2014
EN 60684-3-2853-285: Metal-reinforced/EMI shielding sleeving2014
EN 60684-3-400~4023-400~402: Heat-shrinkable end caps / boots2002
EN 60684-3-403~4053-403~405: Branch/division protection sleeving2002
⚠️ Scanned version, written from public-domain knowledge: most parts are scans; temperature ratings (°C), bore series, wall thickness and withstand test voltages must be read from the official text. This table summarises the role of each sheet.

3. Key Technical Requirements 🛠️

Dimensions and construction. Each sheet prescribes the preferred bore series, wall thickness and length tolerances; braided sleeving also specifies braid density and coating adhesion.

Temperature rating and ageing. Classification by continuous operating temperature (e.g. 105/130/155/180/200 °C grades) verified by accelerated thermal-ageing tests.

Electrical performance. Withstand voltage (electric strength) at the specified voltage, insulation resistance and (where relevant) dielectric constant must be met.

Mechanical and flexibility. Tensile strength, elongation, bending and elastic recovery (extruded) are controlled so the sleeving does not crack during threading and bending.

Flame retardancy and LSZH. Burning tests verify vertical flame self-extinguishing; LSZH grades restrict halogens and smoke density for rail and marine requirements.

Chemical and climatic resistance. Oil, solvent, humidity and UV-ageing tests are executed per the corresponding sheet for long-term environmental suitability.

4. Engineering Practice ⚙️

  • 🔍 Selection: set the temperature grade and mechanical requirement first (extruded/braided/heat-shrink), then choose the specific sheet by environment (oil, solvent, flame, halogen limits).
  • 🔧 Heat-shrink process: choose a shrink ratio matching conductor/termination size and avoid overheating the wire during shrinking.
  • 📊 Acceptance testing: per Part 2, sample-check bore, wall thickness, withstand voltage and flame retardancy on incoming material, verifying the sheet number.
  • 🛡️ Harness protection: add abrasion/shielding sleeving at terminations, grommets and friction points to improve harness reliability and EMI performance.

5. Frequently Asked Questions ❓

❓ Q: How do Part 2 and Part 3 work together?
A: Part 2 defines the test methods (dimensional, thermal, electrical, mechanical, burning, chemical); each sheet in Part 3 specifies a sleeving type and cites the corresponding Part 2 tests and limits. Both are indispensable.
❓ Q: Extruded vs braided sleeving — which to choose?
A: Extruded sleeving (silicone, polychloroprene, PVC) is flexible and sealing, ideal for overall protection; braided sleeving (glass fibre, Nomex) is heat- and abrasion-resistant, suitable for hot and friction-prone positions, often coated for higher withstand.
❓ Q: Why does LSZH sleeving matter?
A: In fire, LSZH material produces little smoke, no halogens and low corrosivity, aiding escape and equipment protection — a hard requirement for rail, marine and crowded places.
❓ Q: May temperature ratings from scanned parts be used?
A: Not recommended. Temperature ratings, bores and voltage limits per sheet should come from the official BSI version.
🔒