📐 BS EN 60534 is the UK implementation of IEC 60534, promoted in the UK by BSI Technical Committee GEL/65 (Measurement and control) through subcommittee GEL/65/2 (Elements of systems). It is the most authoritative control-valve standard family in process control, covering terminology and general considerations, flow-capacity calculation and testing, installation dimensions, the control-valve data sheet, noise prediction and measurement, and terminal markings — the full lifecycle of a control valve. It is widely used by design institutes and instrumentation engineers in the oil, chemical, power and metallurgy industries. The complete set comprises 11 documents.
⚠️ Scanned version, written from public domain knowledge: the source material for this series is scanned (SCAN>0); the technical content below is summarised from publicly known information in the field, and the authoritative text is the official BSI publication.
💡 Part 2-1 gives the world-standard control-valve sizing equations (Cv/Kv coefficients) — the authoritative basis for “how big a valve do we need”. Together with the Part 7 data sheet and Part 8 noise prediction, it forms the complete engineering chain for control valves.
1. Scope and General Overview 📌
A control valve is the final control element of a process-automation loop: by changing the trim opening it regulates the flow of fluid through the valve, thereby controlling pressure, temperature, level and flow-rate process variables. EN 60534 covers industrial-process control valves actuated by pneumatic, electric and hydraulic operators, including single/double-seated globe valves, cage-guided valves, eccentric rotary valves, butterfly valves and ball valves.
The series falls into four groups: general (Part 1) defines terminology and general considerations; flow capacity (Part 2) defines the sizing equations for installed conditions and the test procedures; dimensions (Part 3) defines face-to-face / end-to-end dimensions of flanged and buttweld straight-pattern valves; data sheet (Part 7) and noise (Part 8) support engineering procurement and acoustic design. Part 9 covers terminal/connection marking and supplementary content. The series works with I&C design practices such as IEC 61511 functional safety.
2. Series Structure and Technical Content 🔧
The table below summarises the 11 parts of BS EN 60534 and their subjects. Each part corresponds to the same-numbered part of IEC 60534 to ensure international consistency.
| Part | Subject | Content highlights |
| BS EN 60534-1 (2005) | Control valve terminology and general considerations | Terminology, valve types, inherent characteristics, general design |
| BS EN 60534-2-1 (2011/2015) | Flow capacity — Sizing equations under installed conditions | Cv/Kv equations, compressible/incompressible flow, choked-flow corrections |
| BS EN 60534-2-3 (2016) | Flow capacity — Test procedures | Flow-test procedure to determine rated capacity |
| BS EN 60534-3-1 (2000) | Face-to-face dimensions of flanged control valves | Installation length of flanged straight-pattern control valves |
| BS EN 60534-3-3 (1998) | End-to-end dimensions of buttweld control valves | Length dimensions of buttweld straight-pattern control valves |
| BS EN 60534-7 (2010/2011) | Control valve data sheet | Standardised data sheet for ordering and design |
| BS EN 60534-8-1 (2005) | Noise — Laboratory measurement of aerodynamic noise | Laboratory measurement of noise from gas flow through control valves |
| BS EN 60534-8-2 (2011) | Noise — Laboratory measurement of hydrodynamic noise | Laboratory measurement of noise from liquid flow through control valves |
| BS EN 60534-8-3 (2011) | Noise — Aerodynamic noise prediction method | Prediction of control-valve noise for gas service |
| BS EN 60534-8-4 (2015) | Noise — Hydrodynamic noise prediction method | Prediction of control-valve noise for liquid service |
| BS EN 60534-9 (2007/2009) | Terminal markings and supplementary content | Wiring/marking and informative supplements |
💡 Sizing (Part 2-1) is the entry point of selection: use the liquid equations for liquids and the compressible-flow equations for gases/steam, applying choked-flow, critical-pressure-ratio and piping-geometry corrections; never “one formula fits all”. The current equations are based on the 2011 edition.
3. Key Technical Requirements 🔥
Key technical requirements across the series include:
- Flow coefficients and equations: Part 2-1 defines the conversion of Cv (US) and Kv (metric) (Kv ≈ 0.865 Cv), incompressible and compressible flow equations, choked-flow criteria (X_T, F_L correction factors) and installed-condition corrections (F_p).
- Rated-flow testing: Part 2-3 specifies how to determine the valve’s flow-versus-pressure-drop relationship at full (or specified) opening in a test loop and the associated accuracy requirements.
- Inherent characteristics and rangeability: Part 1 defines flow characteristics (linear, equal-percentage, quick-opening, etc.) and rangeability (R), which affect control quality and loop tuning.
- Noise limits: Part 8 provides noise-prediction methods used in engineering to evaluate downstream pipe noise and design mitigation (silencers, multi-stage pressure-drop trims).
- Standardised data sheet: the Part 7 data sheet unifies ordering information (process conditions, body materials, trim materials, actuator, accessories, testing), reducing engineering ambiguity.
🚨 High-pressure-drop gas service is a hotspot for cavitation and noise: the high-velocity and cavitation produced when media throttles through the valve erode the plug and seat, and radiate intense noise. Sizing must check cavitation criteria (liquid pressure-recovery factor F_L, cavitation coefficient); where necessary use multi-stage pressure-drop or anti-cavitation trims.
4. Engineering Practice 🛠️
- 🔍 Sizing and Cv selection: collect process data (flow, inlet/outlet pressure, temperature, fluid properties), apply the 60534-2-1 equations to compute required Cv, round up to a standard size, and verify loadability at min/normal/max conditions.
- 🔧 Noise control: for high-noise cases, predict sound levels with Parts 8-3/8-4 first; when over limit, choose low-noise trims, silencers or pipe lagging, and state predicted noise in the data sheet.
- 📊 Integration with safety loops: in safety-instrumented-function (SIF) design, a control valve may act as the final element; assess its SIL capability per IEC 61511 and avoid a single point of failure where a control valve also performs safety shutdown.
- 📋 Ordering and acceptance: purchase per the Part 7 data sheet; on receipt verify rated Cv, characteristics, leakage class (per IEC 60534-4), materials and test reports.
5. Frequently Asked Questions ❓
❓ Q: What is the difference between Cv and Kv?
A: Cv is the US flow coefficient (US gal/min at 1 psi drop), Kw is the metric coefficient (m³/h of water at 1 bar drop); conversion is about Kv = 0.865 × Cv. Both sets of equations are given in 60534-2-1.
❓ Q: What is choked flow and why does it need correction?
A: When downstream pressure falls below the vapour pressure (liquid) or critical pressure (gas), flow no longer rises with pressure difference — the valve is “choked”. Part 2-1 corrects with pressure-recovery factor F_L and X_T, otherwise you undersize the valve and capacity is insufficient.
❓ Q: Equal-percentage or linear characteristic?
A: Equal-percentage has low gain at low opening and strong anti-disturbance behaviour, suiting control loops with wide load variation (most process valves); linear suits stable loads where opening should be roughly proportional to flow (e.g. valves paired with flow meters).
🔍 Q: Are the control-valve noise predictions (8-3/8-4) reliable?
A: The prediction methods are based on empirical flow-dynamics models with stated uncertainty; their value is early identification of high-noise cases (high pressure drop, large flow) so mitigation can be designed. For stringent acoustic requirements, still combine laboratory measurement (8-1/8-2) or field verification.