🔌 BS EN 60335 is the UK-implemented European standard system for the safety of household and similar electrical appliances, published by the British Standards Institution (BSI) and identically adopting the IEC 60335 family with CENELEC common modifications. The series consists of one set of general safety requirements — BS EN 60335-1 (General requirements) — and dozens of BS EN 60335-2-x particular requirements covering specific appliance types, from refrigerators, washing machines and irons to floor treatment machines and vaporizers. It is the central harmonised standard for conformity assessment under the EU Low Voltage Directive (2014/35/EU) and the UK equivalent, supporting CE and UKCA marking, and forms the fundamental basis for the safe design, manufacture and testing of appliances worldwide.
💡 BS EN 60335 uses a two-tier “general + particular” structure: BS EN 60335-1 sets the universal safety principles every appliance must meet; each 60335-2-x adds, replaces or deletes clauses of -1 for a particular appliance category. For compliance, -1 and the applicable -2-x must be used together.
1. Overview and Scope 📌
BS EN 60335 is derived from IEC 60335; the UK gives it national status by adopting EN 60335. This batch comprises 95 documents. BS EN 60335-1:2012+A11:2014 is the general safety requirement, published by BSI on 31 May 2012, derived from IEC 60335-1:2010 (corrigendum July 2010) and incorporating the CENELEC A11 common modification. The remaining 94 documents are Part 2 particular requirements.
The series applies to heating, motor-operated, refrigeration, lighting and combined appliances, typically rated up to 250 V single-phase or 480 V for other appliances. Professional equipment such as industrial, medical or arc-welding apparatus is covered by other standards. The series is maintained by BSI Technical Committee CPL/61 (Safety of household and similar electrical appliances).
⚠️ BS EN 60335 addresses only safety (electric shock, fire, mechanical hazards, etc.); it does not cover performance, energy efficiency or electromagnetic compatibility (EMC). EMC must be met separately via BS EN 55014 and related standards. Full compliance requires both -1 and the relevant -2-x.
2. Series Composition and Technical Points 🔧
The table below lists the principal parts of the series (based on the real file list in the material). Of the 95 files, -1 is the general requirement and the rest are -2-x particular requirements.
| Standard | Subject | Example edition | Remark |
| BS EN 60335-1 | General requirements | 2012+A11:2014 | Safety basis for all appliances: shock protection, insulation, temperature, abnormal operation |
| BS EN 60335-2-2 | Vacuum cleaners | 2010+A1 | Vacuum cleaners and water-suction cleaning appliances |
| BS EN 60335-2-3 | Irons | 2016 | Dry and steam irons |
| BS EN 60335-2-7 | Washing machines | 2010+A1 | Household electric washing machines |
| BS EN 60335-2-9 | Toasters, grills | 2003+A13 | Portable cooking appliances |
| BS EN 60335-2-10 | Floor treatment & wet scrubbing machines | 2003+A1:2008 | Managed by CPL/61/01 motorized appliance subcommittee |
| BS EN 60335-2-15 | Appliances for heating liquids | 2016 | Kettles, coffee makers |
| BS EN 60335-2-24 | Refrigerating appliances | 2010 | Refrigerators, freezers |
| BS EN 60335-2-25 | Microwave ovens | 2012+A2 | Includes microwave radiation safety |
| BS EN 60335-2-30 | Room heaters | 2009+A11 | Convector, radiant, fan heaters |
| BS EN 60335-2-101 | Vaporizers | 2002+A2:2014 | Managed by CPL/61/07 heated appliance subcommittee |
| BS EN 60335-2-102, -103 … -2-99 | Various appliances | Multiple | Food preparation, sewing, projection, battery-driven, etc. |
The numbering is logical: -2-2 to -2-99 cover traditional appliance types; numbers above -2-100 (e.g. -2-101, -2-102) were added later for specialised appliances (vaporizers, scent diffusers, extended floor-treatment types). Selecting the right -2-x depends on the appliance’s functional classification.
💡 When determining the applicable part, base the decision on the appliance’s “primary hazard” and “primary function”. Multi-function appliances may need to satisfy several -2-x clauses, taking the most stringent.
3. Key Technical Requirements 🔥
The general safety requirements of BS EN 60335-1 form the technical core of the entire series:
- Electric shock protection: accessible parts must remain non-live under normal use and single fault conditions, achieved through double insulation, reinforced insulation or protective earthing. Definitions and tests for basic, supplementary, double and reinforced insulation are specified.
- Insulation, creepage and clearance: required creepage distances, clearances and distances through insulation vary with insulation level, pollution degree and material group.
- Temperature rise and heat resistance: limits apply to windings, terminals, enclosures and handles under normal and abnormal conditions; non-metallic materials must pass ball-pressure and glow-wire tests for heat and flame resistance.
- Leakage current and electric strength: verified by withstand testing (e.g. basic insulation 1000 V + 2× rated voltage) and leakage current measurement.
- Abnormal operation: motor locked-rotor, fan failure, controller short-circuit, load imbalance and similar faults are simulated to confirm no fire, shock or mechanical hazard results.
- Mechanical hazard and stability: guarding of moving parts, enclosure mechanical strength, appliance stability (e.g. an overturned oven must not ignite), handle strength.
- Construction and materials: internal wiring, flexible cords, earthing continuity, screw and connection reliability, ingress protection (IP code).
- Marking and instructions: rating, earth symbol, warnings and user instructions (including child-safety warnings) are mandatory.
🚨 Electric strength and abnormal-operation tests are high-risk type tests that must be performed in controlled environments by qualified personnel. Incorrect test voltages or wiring can damage samples and create shock hazards.
4. Engineering Application 🛠️
- 🔍 Compliance path: identify appliance category → select BS EN 60335-1 + the relevant 60335-2-x → verify design clause by clause → conduct type tests → compile technical file (including risk analysis) → sign Declaration of Conformity (DoC) → affix CE (EU) or UKCA (UK) marking.
- 📋 Technical file: should contain product description, circuit diagrams, critical component list, test reports and risk assessment. After Brexit, products placed on the GB market need UKCA marking, with the technical file held by a GB-based responsible person.
- 🔧 Critical component control: flexible cords, plugs, thermostats, thermal cut-offs and motors directly affect safety and should be sourced from certified (VDE, UL, BSI) models.
- ♻️ Version tracking: BS EN 60335-1 has integrated the A11 modification; the 2012 edition was withdrawn on 21 November 2014. Design, test and procurement specs should be aligned with the latest edition.
✅ Applying the two-tier “general + particular” structure correctly and introducing clause-by-clause design review early reduces later rework and shortens certification lead time.
5. Frequently Asked Questions ❓
❓ Must BS EN 60335-1 and 60335-2-x be used together?
Answer: Yes. Part -1 is the general safety requirement and is incomplete on its own; each -2-x modifies -1 for a specific appliance. Full compliance requires both, with the most stringent clause prevailing.
❓ What is the difference between BS EN 60335 and IEC 60335?
Answer: BS EN 60335 is adopted by the UK from EN 60335, which in turn identically adopts IEC 60335 but includes CENELEC common modifications (e.g. A11). Differences therefore exist in plugs, colour coding and some test methods; for UK/European markets the BS EN version governs.
❓ Does the series include EMC requirements?
Answer: No. 60335 covers electrical and mechanical safety only. Appliance EMC must meet BS EN 55014 (emissions) and BS EN 61000-3-2/3-3 (harmonics, voltage fluctuations), assessed separately from low-voltage safety.
❓ Many files are marked “scan”; how can clauses be confirmed?
Answer: Of the 95 files, most are scan-based. This article is written from the machine-readable parts (-1, -2-10, -2-101 titles and forewords) combined with public-domain knowledge of IEC 60335. Specific clause values should be taken from the official BSI published version.