BS EN 60099 — Surge Arresters for A.C. Systems Standard Series

Surge Arresters (EN/IEC 60099 Series)

⚡ The BS EN 60099 series is the British Standard published by BSI as the UK implementation of the European EN 60099 series (corresponding to the IEC 60099 series), dedicated to surge arresters for a.c. power systems. It was prepared with UK participation by Technical Committee PEL/37 (Surge Arresters – High Voltage), with ICS classification 29.120.50 and 29.240.10, and is an important basis for the design, manufacture, selection, and testing of overvoltage-protection devices (surge arresters) in power systems, and a foundation for equipment selection in generation, transmission, and substation projects.

💡 The surge arrester is the “fuse” of overvoltage protection for power equipment: it is normally high-impedance, but when the system experiences an overvoltage (lightning, switching), it immediately conducts and discharges the impulse current, limiting the residual voltage to within the equipment’s insulation-withstand level, protecting transformers, circuit-breakers, and insulators.

1. Series Overview 📌

The BS EN 60099 series covers the complete technical system from gapped arresters to modern metal-oxide arresters; this series includes 5 sub-parts:

StandardSubjectMain Content
BS EN 60099-1:1994 (2001)Non-linear resistor gapped arrestersRequirements for non-linear resistor type gapped surge arresters for a.c. systems; identical to IEC 60099-1:1991; supersedes BS 2914:1972
BS EN 60099-4:2014Metal-oxide surge arresters without gapsRequirements for metal-oxide surge arresters (MOA) without gaps for a.c. systems; identical to IEC 60099-4:2014; supersedes the 2004 edition
BS EN 60099-5:2013Selection and application recommendationsApplication recommendations for selection, installation, and operation; supersedes the 1996 edition
BS EN 60099-8:2011Line arrestersRequirements for line arresters with external series gaps (EGLA) (scan version, written from public-domain knowledge)
BS EN 60099-9:2014Metal-oxide arresters (special tests)Additional test methods and requirements for metal-oxide arresters under special duty (scan version, written from public-domain knowledge)
⚠️ BS EN 60099-8 and BS EN 60099-9 in this series are scan versions; their technical content is summarized from public-domain knowledge, and specific clauses and requirements are subject to the official BSI published version.

2. Metal-Oxide Surge Arresters (Part 4) 🔧

Part 4 (Metal-oxide surge arresters without gaps) is the most widely used and important sub-part in modern power systems. It specifies the complete technical requirements for arresters using zinc-oxide (ZnO) non-linear resistors without series gaps. Main technical content includes:

  • Classification and parameters: classifies by nominal discharge current (e.g., 5 kA, 10 kA, 20 kA classes) and specifies continuous operating voltage, rated voltage, and actual continuous operating voltage.
  • Switching and lightning overvoltage protection: specifies residual-voltage characteristics and protection levels under lightning and switching impulses.
  • Energy-absorption capability: specifies the arrester’s capability to absorb switching-overvoltage energy (thermal-stability and energy-withstand tests).
  • Operating characteristics: specifies leakage current, reference voltage, power-frequency voltage-withstand time (T-H) characteristics, and aging characteristics.
  • Test requirements: specifies type tests, routine tests, and sampling tests, including pressure-relief tests.
✅ Modern power systems almost entirely use gapless metal-oxide surge arresters (MOA): their excellent non-linear characteristics, low residual voltage, no follow-current, and no series gaps make their protection performance significantly superior to traditional silicon-carbide gapped arresters.

3. Selection and Application Recommendations (Part 5) 🔥

Part 5 (Selection and application recommendations) provides engineering guidance for arrester application. The 2013 edition has significant technical changes versus 1996, mainly including:

  • Discussion of different arrester types: expands discussion of different arrester types and their applications, including transmission line arresters.
  • Selection principles: choose the appropriate arrester rated voltage and protection level based on system voltage, earthing method, insulation level, and overvoltage characteristics.
  • Installation and earthing: specifies arrester installation location, leads, and earthing requirements, reducing the effect of lead inductance on residual voltage.
  • Operation and maintenance: specifies arrester monitoring (leakage-current monitoring, operation counters), condition assessment, and replacement principles.

Part 8 (Line arresters, scan version) specifies requirements for line arresters with external series gaps (EGLA) for transmission-line lightning protection; Part 9 (scan version) specifies additional test methods for metal-oxide arresters under special duty.

⚠️ Arrester selection must match system insulation coordination: the arrester’s protection level should be below the insulation-withstand level of the protected equipment, with adequate coordination margin; otherwise the arrester cannot effectively protect the equipment.

4. Engineering Practice and Application 🛠️

  • 🔍 System insulation coordination: determine the arrester rated voltage and protection level from the system insulation and overvoltage levels.
  • 📈 Energy verification: for special duty (capacitor compensation, long lines), verify the arrester’s energy-absorption capability and thermal stability.
  • 🔧 Installation optimization: shorten the arrester leads as much as possible to reduce the additional effect of lead inductance on residual voltage, with reliable earthing.
  • 📊 Condition monitoring: track arrester operating state via leakage-current monitoring and operation counters, replacing aged products promptly.
  • 🧪 Type-test acceptance: complete type and acceptance tests per Part 4, verifying test reports and nameplate parameters.

5. Frequently Asked Questions ❓

❓ Q: What is the difference between a surge arrester and a surge protective device (SPD)?
A: A surge arrester is primarily used for high-voltage overvoltage protection in power systems (stricter class, larger energy), typically governed by the IEC/EN 60099 series; an SPD is primarily for overvoltage protection in low-voltage distribution and electronic information systems, governed by the IEC 61643 series.
❓ Q: Why does a gapless metal-oxide arrester not need a series gap?
A: Zinc-oxide non-linear resistors have very high impedance at normal operating voltage with minimal leakage current; under overvoltage, the resistance drops sharply and conducts to discharge current, achieving “no conduction normally, conduction on overvoltage” without a series gap.
❓ Q: What is insulation coordination and why must it match the arrester?
A: Insulation coordination is the coordination between the insulation levels of system equipment and the protection levels of protective devices; the arrester’s protection level must be below the equipment’s insulation-withstand level with margin for effective protection.
🔍 Q: Are the scan-version Parts 8 and 9 reliable?
A: Parts 8 and 9 are scan versions; this article summarizes their technical direction (line arresters and special tests) from public-domain knowledge. Specific clauses and requirements are subject to the official BSI published version.
🔒