📡 BS EN 50117 (European Standard EN 50117) is the series of standards for coaxial cables used in cabled distribution networks, published by BSI with UK participation under Technical Committee EPL/46 (Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling), classified under ICS 33.120.10 (Coaxial cables, waveguides and other RF cables). Drafted under the CENELEC TC 46X (Communication cables) and SC 46XA (Coaxial cables) framework, the series adopts a “generic specification (Part 1) + sectional specifications (Parts 2-x, 3-x, 4-x)” structure, and is the technical basis for the selection, design and acceptance of coaxial cables in CATV, broadband access, surveillance and structured cabling systems. This batch contains nine files; this article interprets the structure and technical requirements of the series.
💡 Coaxial cables carry RF signals in cabled networks: from the antenna/optical node to the building, and from the distribution box to the user terminal. BS EN 50117 organises cables by “generic + sectional specification”, specifying characteristic impedance, attenuation, shielding, and mechanical and environmental requirements — the key to network transmission quality.
1. Series Overview and Scope 📌
BS EN 50117 applies to the various coaxial cables used in cabled distribution networks (CATV, HFC hybrid fibre-coax networks, etc.), including: indoor drop/subscriber cables, outdoor trunk/distribution cables, and cables for telecommunication systems (such as broadband transmission above 5 MHz). The series specifies the cable construction (inner conductor, insulation, outer conductor/shield, sheath), electrical performance (characteristic impedance, attenuation, return loss, shielding attenuation), mechanical performance (bending, tensile, crush) and environmental performance (flame retardancy, weathering, temperature range) requirements and their test methods.
The series uses an integrated “generic + sectional specification” structure: Part -1 is the generic specification giving general requirements and test methods; Parts -2-1 to -2-5 are sectional specifications for indoor/outdoor cables for cabled distribution networks; Part -3-1 is the sectional specification for telecommunication applications; Parts -4-1, -4-2 are sectional specifications for cables at higher frequencies / specific applications. This article covers the nine files of this batch.
⚠️ Shielding performance and the 50 Ω/75 Ω characteristic-impedance match are critical to system engineering. Use 75 Ω cables for broadband distribution and 50 Ω for RF test links; mixing them causes reflection and signal degradation — confirm the system impedance class before selection.
2. Series Structure and Part-by-Part Listing 🧩
| Standard Number | Subject Content | Edition Status |
| BS EN 50117-1 | Generic specification: general requirements and test methods | 2002 edition + A2:2013 |
| BS EN 50117-2-1 | Sectional spec. for indoor drop cables (5 MHz–1000 MHz) | 2005 edition + A2:2013 |
| BS EN 50117-2-2 | Sectional spec. for outdoor cables | 2004 edition + A2:2013 |
| BS EN 50117-2-3 | Sectional spec. for indoor/outdoor cables | 2004 edition + A2:2013 |
| BS EN 50117-2-4 | Sectional spec. for indoor cables | 2004 edition + A2:2013 |
| BS EN 50117-2-5 | Sectional spec. for indoor/outdoor cables | 2004 edition + A2:2013 |
| BS EN 50117-3-1 | Sectional spec. for telecommunication application cables | 2002 edition (scanned) |
| BS EN 50117-4-1 | Sectional spec. for higher-frequency/specific application cables | 2008 edition + A1:2013 |
| BS EN 50117-4-2 | Sectional spec. for higher-frequency/specific application cables | 2015 edition |
BS EN 50117-1:2002+A2:2013 (generic specification), BS EN 50117-2-1:2005+A2:2013 and BS EN 50117-2-2:2004+A2:2013 are the readable files of this batch. The A2:2013 revision mainly updated clause 5.4 and similar content concerning dimensional and performance requirements, ensuring consistency with the new sectional specifications.
✅ The existence of sectional specifications lets engineering select precisely by “application scenario”: indoor drop cables focus on flexibility and flame retardancy, outdoor cables on weathering and moisture resistance, and trunk cables on low attenuation and strong shielding. Choosing the right sectional specification means the performance indices and test methods are automatically aligned.
3. Core Requirements of the Generic Specification (-1) 🔧
BS EN 50117-1 sets out the general requirements and test methods for all coaxial cables, mainly including:
- Construction requirements: inner conductor (solid/stranded), insulation type (foamed PE, solid PE, etc.), outer conductor/shield structure and sheath material.
- Electrical performance: characteristic impedance (usually 75 Ω, 50 Ω for specific uses), attenuation constant, return loss/structural return loss, shielding attenuation (transfer impedance), insulation resistance and withstand voltage.
- Mechanical and environmental performance: minimum bending radius, tensile/crush resistance, temperature range (e.g., −40 °C to +70 °C), flame-retardant class and other fire-safety requirements.
- Test methods: specify the measuring apparatus, conditions and procedures for each property, ensuring comparability of test results.
🚨 Shielding attenuation is the core indicator of interference immunity in digital broadband networks: insufficient shielding lets external EMI ingress and worsens multi-user crosstalk bit-error rates. Engineering should check the shielding class per the sectional specification (e.g., class A / class B) and sample-acceptance-test by the transfer-impedance method of the generic specification.
4. Sectional Specifications and Engineering Application 🎯
4.1 Indoor/outdoor cables (-2-1 to -2-5)
The sectional specifications cover different application segments of the cabled distribution network: indoor drop cables require flexibility, flame retardancy and easy bending; outdoor cables require UV resistance, moisture resistance and temperature-cycle resistance; trunk/distribution cables use low-attenuation, high-shielding structures. The sectional specifications set the respective dimensions, performance classes and marking requirements on top of the generic specification.
4.2 Telecom and higher-frequency cables (-3-1, -4-1, -4-2)
Part -3-1 targets telecommunication applications (such as broadband data access); -4-1 and -4-2 aim at higher operating frequencies or specific application scenarios (e.g., indoor distribution systems, higher-band transmission), specifying stricter construction and transmission performance requirements.
⚠️ Most sectional files in this batch are scanned versions with limited readable content. The descriptions of sectional specifications other than -1, -2-1, -2-2 are summarised from public-domain knowledge of the field; the specific dimensions and performance limits must be taken from the official BSI published text.
5. Engineering Practice and Application Advice 🛠️
- 🔍 Selection principle: select the corresponding sectional specification by network application segment, confirming characteristic impedance (75 Ω/50 Ω), frequency range and shielding class.
- 🔧 Construction and installation: control bending radius, avoid tensile and crush; match the connector impedance to the cable, and follow the process spec for soldering or crimping.
- 📊 Acceptance testing: sample-test key indicators (attenuation, return loss, shielding) and keep batch reports for warranty traceability.
- 📋 Standard updates: the A2:2013 revision is in effect; new networks are recommended to organise design and procurement to the current edition.
6. Frequently Asked Questions ❓
❓ Q: Why are 75 Ω coaxial cables mostly used for cable TV?
A: 75 Ω strikes a good compromise between low attenuation and power handling and is the conventional impedance of broadband distribution networks; 50 Ω is commonly used for test instruments and RF links. Mixing them causes reflection.
❓ Q: Is shielding attenuation important?
A: Very. It determines the cable’s ability to resist external interference and suppress outward radiation, directly affecting the bit-error rate of broadband signals and network reliability, so it should be a focus of acceptance.
❓ Q: Can indoor and outdoor cables be interchanged?
A: Not recommended. Outdoor cables are designed for weathering, moisture and temperature cycling, while indoor cables focus on flexibility and flame retardancy; interchange leads to mismatched life and performance.
🔍 Q: Can the scanned sectional specifications be used directly for procurement?
A: The macro structure and system are based on public-domain knowledge and are suitable for initial reference; formal procurement and acceptance should be based on the official BSI-published sectional specification text.
💡 Network transmission quality is the combined result of “cable + connector + construction craft”. BS EN 50117 standardises cable performance; in engineering, persist in “select by sectional specification, test by generic specification, construct by process specification”.