📡 BS EN 50065 is the UK national standard implementing the European standard series EN 50065 “Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz”, prepared by CENELEC with UK participation through Technical Committee PEL/205 (Mains signalling). The series specifies frequency-band allocation, general requirements, immunity requirements, and the low-frequency communication requirements of equipment and systems in each band for power line communication (PLC) over the low-voltage grid. It is an important basis for the design and conformity assessment of narrowband PLC products in smart metering, home automation, and building control.
The low-voltage power line is an attractive but noisy and lossy communication medium. To prevent mutual interference between applications, EN 50065-1 specifies the frequency-band allocation, e.g. Band A (3 kHz–95 kHz, for utility services), Band B (95 kHz–125 kHz, no access-protocol restriction), Band C (125 kHz–140 kHz, home systems with a CSMA access protocol), and Band D (140 kHz–148.5 kHz, alarm and security systems). Part 1 gives the general requirements, frequency bands, and electromagnetic disturbance properties; Parts 2-x give immunity requirements for equipment in different environments (residential, industrial, etc.); Parts 4-x give low-frequency communication requirements for equipment and systems in each band; Part 7 covers frequency-range extension.
| Part | Content | Edition |
|---|---|---|
| Part 1 | General requirements, frequency bands and electromagnetic disturbances | 2011 |
| Part 2-1 | Immunity requirements for mains communications equipment in the range 95 kHz to 148.5 kHz for residential environments | 2003 (2006) |
| Part 2-2 | Immunity requirements for mains communications equipment in the range 95 kHz to 148.5 kHz for industrial environments | 2003 (2007) |
| Part 2-3 | Immunity requirements in the public mains environment, 95 kHz to 148.5 kHz | 2003 (2006) |
| Part 4-1 | Low-frequency transmitters / mains communications equipment (utility services), 3 kHz to 95 kHz | 2002 |
| Part 4-2 | Low-frequency receivers, 3 kHz to 95 kHz | 2002 (2005) |
| Part 4-3 | Low-frequency transmitters, 95 kHz to 148.5 kHz | 2003 |
| Part 4-4 | Low-frequency receivers, 95 kHz to 148.5 kHz | 2003 |
| Part 4-5 | Narrow-band filter requirements | 2003 |
| Part 4-6 | Requirements for decoupling devices in Band A | 2004 |
| Part 4-7 | Portable low-voltage decoupling devices (impedance filters) | 2005 (2007) |
| Part 7 | Frequency range extension (146.5 kHz to 1 MHz, etc.) | 2001 |
This standard specifies the frequency-band allocation, emission limits (output terminal voltage limits), in-band and out-of-band disturbance limits, measurement methods, and access-protocol requirements (Band C uses a CSMA-type protocol for collision avoidance). It supersedes the 2001+A1:2010 edition, harmonising coexistence rules for different applications in the band and giving general requirements for all equipment.
PLC equipment must withstand conducted transients, surges, RF fields, and electrostatic discharge on the mains. Parts 2-1, 2-2, and 2-3 specify, for residential, industrial, and public-mains environments respectively, the immunity test levels and criteria for mains communications equipment and systems in the 95 kHz to 148.5 kHz band, ensuring reliable operation in noisy environments.
Part 4-1 specifies the requirements for transmitters in the 3 kHz to 95 kHz band (Band A, utility services such as load control and remote metering), Part 4-3 for transmitters in the 95 kHz to 148.5 kHz band, and Parts 4-2/4-4 for the corresponding receivers. Parameters such as output level, frequency tolerance, modulation characteristics, and out-of-band suppression are specified, together with requirements for narrow-band filters (4-5), decoupling devices (4-6), and portable decoupling devices (4-7).
Part 7 specifies requirements for extending the operating range beyond the basic band (e.g. towards 1 MHz) for higher-data-rate PLC applications, while controlling interference to other services.