🏊 BS EN 16713 is a European Standard series developed by CEN for the water systems of domestic (private) swimming pools, implemented in the United Kingdom by BSI under the designation BS EN 16713, with UK participation entrusted to Technical Committee SW/136/8 (Swimming pools and aquatic equipment). The series comprises three parts covering the filtration system, the circulation system and water treatment, providing a harmonised European set of technical requirements and test methods for pool water quality, hygiene and safety — an essential reference for manufacturers, installers and designers.
💡 A domestic pool water system is a closed loop of filtration, circulation and treatment: filtration removes particulates, circulation ensures uniform flow and adequate turnover, and treatment (disinfection and chemical conditioning) maintains microbiological safety. The three parts interlock and are inseparable.
1. Series Overview and Scope 📌
The BS EN 16713 series consists of EN 16713-1:2016, EN 16713-2:2016 and EN 16713-3:2016, all approved by CEN on 5 December 2015 and published as British Standards by BSI on 29 February 2016. The standards target the “domestic (private) swimming pool” scenario — pools that are not generally accessible to the public and are primarily for family use. Their technical stringency differs from public-pool standards such as BS EN 15288, better matching the conditions of home use and maintenance.
| Part | Standard | Subject | Key Content |
| Part 1 | BS EN 16713-1:2016 | Filtration systems | Requirements and test methods |
| Part 2 | BS EN 16713-2:2016 | Circulation systems | Requirements and test methods, including filtration system design |
| Part 3 | BS EN 16713-3:2016 | Water treatment | Requirements, including fill water specification |
⚠️ This standard applies only to private domestic pools. If a pool is open to the public or operated commercially (hotels, fitness centres, public water parks), the corresponding public-pool standards and regulations apply — do not substitute BS EN 16713 requirements.
2. Filtration System Requirements (Part 1) 🔧
BS EN 16713-1 specifies the performance requirements and test methods for the filtration system of a domestic pool. Filtration is the first barrier of water treatment: its core task is to remove suspended solids, hair, skin flakes and other contaminants by mechanical means, providing a sound basis for subsequent disinfection. The standard sets requirements for filter area, flow rate, backwashing capability and structural safety, and gives the corresponding test procedures so that the system maintains a stable clarifying performance under normal conditions of use.
- Filtration capability: the filter shall effectively remove suspended solids at the specified circulation flow, keeping the pool water clear.
- Structural strength and sealing: the filter and its pipework shall not leak or rupture under normal working pressure and possible pressure fluctuations.
- Backwashing: an operable backwashing or cleaning function shall be provided to keep the filter medium working effectively over the long term.
- Test methods: procedures are given for measuring filtration efficiency, pressure drop and flow characteristics, ensuring repeatable results.
3. Circulation System Requirements (Part 2) 💧
BS EN 16713-2 specifies requirements and test methods for the circulation system of a domestic pool and includes the design requirements for the filtration system. The circulation system keeps the pool water flowing continuously and uniformly through the filtration and treatment equipment, maintaining a consistent water quality throughout the pool. The standard sets requirements for pump flow, pipe layout, suction/inlet positions, turnover time, and provides guidance for the sizing and design of the filtration system.
✅ Good circulation design avoids “dead zones”: the placement of suction and return inlets should agitate the water evenly so that disinfection and filtration cover the whole pool without leaving hygiene blind spots.
4. Water Treatment Requirements (Part 3) 🧪
BS EN 16713-3 specifies requirements for the water treatment of a domestic pool, centred on microbiological safety and user comfort. The standard gives a fill water specification for make-up water and provides technical requirements for disinfection, pH adjustment and clarifier use, ensuring effective control of pathogenic micro-organisms. Associated requirements for water quality monitoring and maintenance give domestic users a basis for day-to-day management.
- Disinfection: suitable disinfection (e.g. chlorine-based products) shall be provided to maintain an effective disinfectant concentration and inhibit bacteria and algae.
- pH control: pH shall be maintained within a recommended range that is comfortable and effective for disinfection, protecting skin and eyes while preserving disinfectant efficacy.
- Fill water quality: make-up water shall meet the specified hygienic quality to avoid introducing contamination.
🚨 Safety warning: the electrical parts of water-treatment equipment must comply with the relevant electrical safety standards; disinfectants (especially chlorine products) shall be stored safely out of reach of children; any electrical installation or maintenance work shall be carried out by qualified personnel.
5. Series Synergy and Engineering Practice 🛠️
The three parts form a complete technical chain for a domestic pool water system. In engineering practice and product development, follow this approach:
- 🔍 Design and selection: first determine the circulation flow and turnover time from the pool volume, then select a matching filtration system, and finally configure the water-treatment equipment; the capacities of the three must be mutually consistent.
- 📋 Materials and compliance: materials shall be water-resistant, chemically resistant, and shall not release harmful substances into the water; products should provide a performance declaration in accordance with this series.
- 🔧 Installation and acceptance: after installation, run the system to verify circulation flow, filtration effect and water-quality parameters.
- 🧹 Daily maintenance: regularly backwash the filter, top up disinfectant, and monitor pH and disinfectant concentration — this is the key to maintaining compliant water quality.
6. Frequently Asked Questions ❓
❓ Q: What is the difference between BS EN 16713 and BS EN 15288?
A: BS EN 16713 covers the water systems (filtration, circulation, treatment) of private domestic pools, while the BS EN 15288 series covers the safety design requirements for public/commercial pools. The use scenarios, requirements and stringency differ; select according to the pool’s nature.
❓ Q: What does “turnover time” mean in the standard?
A: It is the time needed to circulate and filter the entire pool volume once. A reasonable turnover time depends on the combined flow of the filtration and circulation systems and directly affects water quality uniformity and filtration effectiveness; it is an important design check parameter.
❓ Q: Is filtration alone sufficient to meet Part 3?
A: No. Filtration only removes particulates; it cannot kill bacteria or viruses. The water-treatment part requires both effective disinfection and pH control to ensure microbiological safety.
🔍 Q: Should a domestic pool maintain disinfectant concentration continuously?
A: Yes. Even when unused, a basic disinfectant concentration and circulation operation should be maintained to prevent bacterial growth and algae bloom, verified by regular testing to keep the water quality compliant.