BS EN 15287 — Chimney Design, Installation and Commissioning Series

Chimneys — Design, Installation and Commissioning of Chimneys (2007/2008 Edition)

🏠 The BS EN 15287 series is the European standard for the design and installation of chimneys, adopted by the British Standards Institution (BSI) as BS EN 15287-1:2007+A1:2010 and BS EN 15287-2:2008. It specifies design, installation and commissioning requirements for chimneys and flues serving two classes of heating appliance — non-roomsealed (room-air dependent) and roomsealed (independently air-supplied) — providing the basis for design and acceptance of residential and commercial heating flue systems.

✅ The UK national foreword states that BS EN 15287-1 may be regarded as complementary to BS 5440-1:2008; its National Annexes NA to NE (informative) identify the provisions required to meet the UK devolved administrations’ Building Regulations for chimneys, drawing on recommendations from BS 6461-1:1984 and BS 7566 (all parts).

1. Series Structure and Scope 📌

The BS EN 15287 series consists of two parts, distinguished by the appliance’s combustion-air source:

PartObjectAppliance TypeKey Points
BS EN 15287-1:2007+A1:2010Chimneys for non-roomsealed appliancesRoom-air dependent combustion appliances (incl. wood, peat)Design, installation, commissioning; National Annexes NA–NE
BS EN 15287-2:2008Chimneys for roomsealed appliancesIndependently air-supplied sealed appliancesDesign, installation, commissioning

UK participation was entrusted to Technical Committee B/506 (Chimneys) and the series is classified under ICS 91.060.40 (Chimneys, shafts). Part 2 has no national annex; for Part 1, Annexes NA to ND give installation recommendations for domestic solid-fuel (including wood and peat) appliance chimneys and flues, and Annex NE covers information relevant to chimneys for gas and oil appliances.

⚠️ Chimney design and installation involve fire-safety and carbon-monoxide risks and must strictly follow the standard together with local building regulations. In Part 1, National Annex NA.2 (subclause 7.2) was revised in July 2013 — check the edition when referencing.

2. Chimney Design Essentials 🔧

The standard’s design requirements mainly cover:

  • Ventilation capacity: cross-section and height shall suit the appliance’s flue-gas volume, producing adequate draught under specified operating conditions.
  • Materials and construction: materials shall withstand flue-gas temperature and condensate corrosion; the structure shall be stable and meet fire-resistance requirements.
  • Clearances and protection: distances to combustible elements, insulation and fire breaks shall meet requirements to prevent fire spread.
  • Position and termination: the outlet position and height shall avoid downdraught, contamination of neighbouring buildings and adverse wind effects.
  • Roomsealed chimney (Part 2): must satisfy system tightness, condensate drainage and positive-pressure operation requirements.
🚨 Insufficient draught can cause flue gases to spill into the room, leading to carbon-monoxide poisoning; excessive draught lowers combustion efficiency and increases heat loss. Always verify chimney ventilation capacity against the appliance nameplate data and local climate during design.

3. Installation Requirements 🛠️

The standard’s installation requirements mainly cover:

  • Competence: installation shall be carried out by competent persons following the manufacturer’s instructions.
  • Connection and sealing: the connection between appliance and chimney shall be leak-tight to avoid flue-gas escape; connections between different materials and components shall conform.
  • Support and fixing: the chimney shall be adequately supported and fixed to resist wind load, self-weight and thermal expansion.
  • Condensate and drainage: condensing chimneys shall have condensate collection and disposal measures to prevent corrosion of chimney and building.
  • Access openings: necessary access openings (cleaning points) shall be provided for inspection and sweeping.

4. Commissioning and Acceptance 📋

After installation, the chimney shall be commissioned and accepted:

  • Functional check: verify draught, tightness and flue-gas discharge.
  • Safety verification: verify clearances to combustible elements and fire-protection measures.
  • Appliance integration: carry out lighting and running tests with the appliance, confirming normal combustion and no flue-gas leakage.
  • Documentation: hand over design, installation and commissioning records to the owner/user, with correct use and maintenance instructions.

5. Engineering Practice and Application 🛠️

  • 🔍 Scheme design: determine chimney type, position and size at the design stage, allowing space and access for later installation.
  • 🔧 Construction coordination: coordinate chimney works with civil, roofing and finishing trades, with proper waterproofing and capping.
  • 📊 Periodic maintenance: inspect and sweep the chimney regularly to prevent soot and tar accumulation causing blockage and fire.
  • 📋 Regulatory compliance: in the UK, chimney design and installation must meet local Building Regulations; BS EN 15287 with National Annexes provides a route to compliance.

6. Frequently Asked Questions ❓

❓ Q: What is the difference between BS EN 15287-1 and 15287-2?
A: Part 1 covers chimneys for non-roomsealed (room-air dependent) appliances; Part 2 covers chimneys for roomsealed (independently air-supplied) appliances. System requirements differ.
❓ Q: What is the purpose of the UK National Annexes?
A: National Annexes NA–NE (informative) identify the provisions required to meet UK Building Regulations for chimneys: NA–ND for solid-fuel appliances, NE for gas and oil appliances, providing local installation guidance.
❓ Q: What if the chimney draught is too weak or too strong?
A: For weak draught, check height, cross-section and blockage; for excessive draught, adjust the appliance damper or use a draught damper. Any adjustment must follow design calculation to avoid compromising safety.
❓ Q: Why does a chimney need regular sweeping?
A: Soot, tar and condensate accumulate on the inner wall, reducing cross-section, lowering draught, causing flue-gas leakage and even chimney fire, so regular inspection and sweeping are essential.
❓ Q: How does this series relate to BS 5440-1?
A: BS 5440-1:2008 is a UK code of practice on flues and ventilation; the UK foreword to BS EN 15287-1 states it may be regarded as complementary, and the two are used together to meet UK requirements.
🔒