๐ The BS EN 15254 series, prepared by the European Committee for Standardization (CEN) and adopted in the UK by BSI, is the standard series on the extended application (EXAP) of results from fire resistance tests, prepared with UK participation by Technical Committee FSH/22 (Fire resistance tests), with ICS classification 13.220.50 (Fire protection) among others. Fire resistance tests (e.g. the EN 1364 series) can only be performed on a limited number of specimens, yet real projects vary enormously in member size, materials and construction. “Extended application” (EXAP) provides a set of rules, based on test data, that extend test results to similar untested members, avoiding expensive full-scale fire tests for every combination. The BS EN 15254 series specifically targets non-loadbearing walls, giving extended application rules for different wall constructions.
๐ก Extended application (EXAP) is the “bridge” between fire resistance testing and engineering use: starting from a limited set of test data, it extrapolates via parameterised rules (permitted variations in size, material and construction) to obtain the fire rating of untested members โ a key means of reducing certification cost and broadening standard coverage.
1. Scope and Series Structure ๐
This series applies to the extended application of fire resistance test results for non-loadbearing walls (including partitions and curtain walls), covering masonry, gypsum board, glass, concrete/lightweight component and metal sandwich panel wall constructions. The series comprises five parts (note that it starts from Part 2; Part 1 is not in this batch):
| Part | Subject | Wall construction type |
| BS EN 15254-2:2009 | Masonry and gypsum blocks | Masonry (brick/block) and gypsum block non-loadbearing walls |
| BS EN 15254-4:2008+A1:2011 | Glazed constructions | Glass curtain walls and glass partitions |
| BS EN 15254-5:2009 | Mineral wool composite panels (scanned) | Composite panel walls with mineral wool (rock wool) core |
| BS EN 15254-6:2014 | Concrete/lightweight components (scanned) | Concrete and lightweight component non-loadbearing walls |
| BS EN 15254-7:2012 | Metal sandwich panels (scanned) | Metal-faced sandwich panel non-loadbearing walls |
โ ๏ธ This series applies to non-loadbearing walls (walls that do not carry structural load). For loadbearing walls/elements, other applicable standards (such as BS EN 15725) should be used โ do not mix them.
2. Basic Principle of Extended Application ๐ง
The core of EXAP is “parameterised extrapolation”. Starting from one or a few full-scale fire tests, the rating of untested members is obtained through the following steps:
- Reference test data: select representative reference specimen test results, including fire resistance time, deformation, temperature and failure mode.
- Parameter rules: establish the effect on fire performance of dimensions (height, width, thickness), material properties (density, strength, thermal conductivity) and construction details (connections, joints, fixing spacing).
- Safety margin: introduce safety factors or conservative values in extrapolation to ensure reliability and traceability of the extended application result.
- Verification and reporting: the extrapolation calculation and conclusions should be evaluated by a competent body and issued as an extended application (EXAP) report.
3. Extended Application Rules by Part ๐ฅ
BS EN 15254-2:2009 covers masonry and gypsum block walls, giving extension rules for wall thickness, material strength and height variations. BS EN 15254-4:2008+A1:2011 covers glazed constructions, considering glass type (laminated, insulated, monolithic), framing, fire-resistant and heat-resistant glass parameters to determine the extended application range.
BS EN 15254-5:2009 covers mineral wool composite panel walls. Notably, the UK committee voted against its approval as a European Standard and set out three concerns in the UK national foreword: first, Table 2 is unclear as a rule for the orientation parameter for panel joints, and the UK interpretation is that a test result is generally valid only for the tested orientation; second, subclause 5.2.4.2 allows an increase in binder content of mineral wool of 2% for products with binder content below 10%, which the UK committee fears could change fire resistance properties and negatively affect test performance; third, subclause 5.3.1 and Annex B present a model for calculating increased span lengths with an ultimate limit of 12 m, which the UK committee considers too high and not validated by testing. Care should be taken when applying this part.
๐จ BS EN 15254-5 has limitations flagged by the UK committee: the applicability of the panel joint orientation rule, mineral wool binder content increase, and the 12 m ultimate span needs careful assessment. In fire safety assessments, particular caution is warranted, and test results should prevail where necessary.
4. Engineering Practice and Application ๐ ๏ธ
- ๐ Using extended application: where a wall construction is close to a tested reference but with size/material variations, the corresponding part’s extension rules can rate the fire resistance, reducing repeat testing.
- ๐ง Reporting and compliance: extended application conclusions should be issued as a formal EXAP report and used as a basis for fire design review and acceptance.
- ๐ Safety assessment: for mineral wool composite panel walls covered by BS EN 15254-5, the limitations raised by the UK committee should be considered in fire risk assessment, supplementing with full-scale tests where necessary.
- ๐ Alignment with related standards: extended application standards work with the base fire resistance test standards (e.g. EN 1364); the reliability and representativeness of the base tests directly affect the credibility of the extended application.
5. Frequently Asked Questions โ
โ What is “extended application” (EXAP)?
Extended application is a technical method that generalises the results of a limited number of full-scale fire resistance tests to similar untested members via parameterised rules, for rating the fire resistance of actual project members.
โ Why not fire test every member type directly?
Full-scale fire tests are expensive and time-consuming, and member combinations in projects are endless. EXAP extrapolates from test data to cut cost and broaden coverage, provided the rules and safety margins are reliable.
โ Does BS EN 15254 apply to loadbearing walls?
No. This series addresses non-loadbearing walls; loadbearing elements should use other applicable standards (such as BS EN 15725) for extended application.
๐ What should be particularly noted for mineral wool composite panel walls under BS EN 15254-5?
The UK committee raised concerns over the panel joint orientation rule, the mineral wool binder content increase, and the 12 m ultimate span. These limitations should be fully assessed, supplementing with tests or adopting more conservative ratings where needed.