Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
✂️ ASME/ANSI PALD-14a-1990 is the first addenda to the Scissors Type Mobile Lifts volume, ASME PALD-14-1989. Approved by ANSI on May 30, 1990 and issued on July 24, 1990, it revises the affected clauses of the 1989 edition through the replacement-page mechanism, with margin notes (a) marking the modified areas. Mirroring PALD-13a-1989, this revision completes the “proof load” definition and clause 3.4 with a tiered requirement (150% vs. 125%) depending on whether an internal load limiting device is fitted, revises the operating controls clause, and adds inspection clause 7.1.5.
Per the Summary of Changes, the modifications in PALD-14a-1990 are:
| Page | Location | Change |
|---|---|---|
| 5 | Section 2 — Definitions | Definition of proof load revised |
| 5 | 3.1 Operating Controls | Revised |
| 6 | 3.4 Proof Load | Revised in its entirety |
| 8 | 7.1.5 | Added |
The revised 3.4 sets the proof load tier by equipment configuration, anchored on the “load limiting device” concept:
The logic: a limiting device caps the lift’s actual lifting capability, making a 150% overload physically unattainable; verifying 125% within the device’s envelope covers the limit state. Lifts without such devices must be verified at the 150% margin. Inspectors must apply the multiplier matching the actual configuration.
| Configuration | Proof Load Multiplier | Basis | Purpose |
|---|---|---|---|
| No internal load limiting device | 150% of rated capacity | 3.4(a), 5.1.1 | Full-travel structural integrity verification |
| Internal load limiting device fitted | 125% of rated capacity | 3.4(b), 5.1.1 | Strength verification within the limiting device envelope |
The revised 3.1 makes explicit that control operation must be clear to the operator by position, function, labeling, or a combination thereof, and that the release system requires intentional positive action to prevent accidental lowering. Combined with the 1989 base clauses, the complete safety design of a scissors type mobile lift includes travel limits (3.2), overload capacity (3.3), proof load (3.4), a secondary load holding means (3.5), and saddle restraints with limited lateral adjustment (3.6). The newly added 7.1.5 belongs to the operation, maintenance, and inspection section and must be included in inspection checklists.
From a management standpoint, users should also note the following. First, the scissors pivot points and pneumatic seals are the areas most prone to wear and leakage; periodic inspection should focus on pivot pins, air-line fittings, and seal condition, with immediate removal from service on wear or leakage. Second, maintenance and calibration of the limiting device belong in the equipment file — any adjustment must be performed and recorded by authorized personnel, preventing operators from changing set points. Third, training should combine the standard’s requirements with the manufacturer’s specific operating steps and maintenance intervals to form a complete safety management system. Fourth, because this addenda adds inspection clause 7.1.5, checklists and work instructions should be updated and the new requirement communicated in refresher training. For export or outsourced procurement, cite the current consolidated version (1989 edition plus all addenda) in contracts and require the manufacturer to supply limiting-device set-point documentation and tiered verification test reports, locking in standard conformance at the document level.