🚗 ASME/ANSI PALD-13a-1989 is the first addenda to the Swing Type Mobile Lifts volume, ASME/ANSI PALD-13-1988. Approved by ANSI on July 19, 1989 and issued on September 15, 1989, it revises the affected pages of the 1988 edition through the replacement-page mechanism, with margin notes (a) marking the modified areas. The core of this revision is harmonizing the proof load requirement with load limiting devices: the definition of proof load and clause 3.4 now set a tiered verification multiplier — 150% for lifts without internal load limiting devices and 125% for lifts so equipped — while the operating controls clause is further clarified.
Per the Summary of Changes, the modifications in PALD-13a-1989 are:
| Page | Location | Change |
|---|---|---|
| 1 | Introduction | Second paragraph of General revised |
| 2 | Section I (Scope) | Revised |
| 5 | Section 2 — Definitions | Definition of proof load revised |
| 5 | 3.1 Operating Controls | Revised |
| 6 | 3.4 Proof Load | Revised |
The most notable change is the tiered proof load requirement in 3.4, which answers the establishment of the term “load limiting device” in the definitions. Under the revised clause:
The logic of the tiering: an internal load limiting device inherently caps the lift’s actual lifting capability, so a 150% physical overload is not attainable; 125% is the reasonable structural verification multiplier. Lifts without such a device must retain the 150% safety margin. Designers and inspectors must apply the verification multiplier that matches the equipment configuration.
| Configuration | Proof Load Multiplier | Basis | Purpose |
|---|---|---|---|
| No internal load limiting device | 150% of rated capacity | 3.4(a), 5.1.1 | Full-travel structural integrity verification |
| Internal load limiting device fitted | 125% of rated capacity | 3.4(b), 5.1.1 | Verify strength within the limiting device envelope |
The revised 3.1 requires controls designed so their operation is clear to the operator by position, function, labeling, or a combination thereof, and the release system must require intentional positive action to prevent accidental lowering. Together with the 1988 base requirements, the complete safety design of a swing type mobile lift includes travel limits (3.2), overload capacity (3.3), proof load (3.4), a secondary load holding means (3.5, automatic stop on loss of air pressure), and saddle restraints (3.6). For marking, rated capacity must be durably displayed in a prominent location, with manufacturer identification and a serial number or date code.
From an engineering-application standpoint, this revision also links the limiting device to the test program: when a lift has an internal load limiting device, the device’s set point defines the boundary condition of verification, so inspectors should confirm the device is intact and functional before testing — a failed device must not be used to claim the lower 125% tier. Similarly, lifts without a limiting device should not evade the 150% verification by adding temporary flow-restricting elements. For users, the limiting device should be part of periodic inspection: check whether the set point has been altered, whether seals are intact, and record the results. Because this addenda also revises the operating controls clause, operator training should be updated to emphasize control identification and the intentional nature of release action, preventing accidental lowering through inadvertent release. In procurement, specify in the technical agreement whether the lift is configured with a limiting device and the corresponding proof load tier, and require verification test reports at the applicable multiplier on delivery.