🔥 ASME CRTD-34-1994 is a consensus operating-practices document prepared by the Feedwater Quality Task Group for the Industrial Subcommittee of the ASME Research and Technology Committee on Water and Steam in Thermal Power Systems. It presents a full set of recommended feedwater and boiler water chemistry control values for modern industrial, high-duty, primary-fuel-fired boilers (oil, gas, or coal). An expansion and revision of the 1979 original, the document is aimed at minimizing the penalties of severe corrosion or deposition, frequent cleaning requirements, and unscheduled outages in steam generator systems and their auxiliary steam users. It remains one of the authoritative references for industrial boiler water-chemistry operation.
The document establishes chemistry control limits for six classes of boilers (Tables 1 through 6):
The chemistry values apply to steam generators in continuous or relatively steady-state operation, including current-design boilers with locally high heat fluxes up to 1.5 × 105 Btu/hr·ft² (473.2 kW/m²), potentially uncertain circulation, relatively small steam drums, and relatively small furnaces. Special operating conditions — startup, shutdown, rapidly fluctuating loads, or initial operation of new boilers — may impose greater water chemistry restrictions. The document explicitly excludes mobile locomotive boilers, boilers of copper or other unusual materials, immersion-type and low-voltage electrode boilers, heating boilers of special construction, waste heat boilers of unusual design, firetube boilers with superheaters, hot water boilers, and oil field steam flood boilers.
Proper treatment of makeup and feedwater is necessary to prevent scale, other deposits, and corrosion in the preboiler, boiler, steam, and condensate systems, and to provide the required steam purity. The document emphasizes that where a choice is available, the reduction or removal of objectionable constituents by pretreatment external to the boiler is always preferable to, and more reliable than, managing those constituents inside the boiler by internal chemical treatment.
The consensus chemistry controls for the six classes are presented in Tables 1 through 6, categorized by operating pressure range. Pressure is the prime factor because it dictates the internal water-chemistry regime, the normal cycles of feedwater concentration, the silica volatility, and the carryover tendency. The density difference between steam and water decreases with increasing pressure and temperature, making phase separation in the drum harder; the tendency to carry over is greater at higher pressure, so boiler-water concentrations must be kept lower to meet the same steam purity target.
| Table | Boiler Class | Basis of Categorization | Key Parameters |
|---|---|---|---|
| Table 1 | Industrial watertube with superheaters, turbines | Pressure range | Steam purity, SiO₂, phosphate, pH, conductivity |
| Table 2 | Industrial watertube without superheaters/turbines | Pressure range | Hardness, alkalinity, pH, TDS, suspended solids |
| Table 3 | Industrial firetube | Pressure range | Alkalinity, TDS, sludge control, phosphate |
| Table 4 | Industrial coil-type watertube | Pressure range | Hardness, SiO₂, dissolved oxygen, cycles |
| Table 5 | Marine propulsion watertube | Pressure range | Congruent phosphate-pH control, steam purity |
| Table 6 | Electrode, forced circulation, jet | Pressure range | Conductivity, pH, dissolved solids |
The text notes that industrial boilers using high-purity demineralized or evaporated makeup water should be operated with a minimum of 1% blowdown (100 cycles of feedwater concentration) to avoid excessive concentration of trace contaminants and possible deposit formation. Congruent phosphate-pH control, coordinated phosphate-pH control, volatile treatment (AVT), chelants, polymers, and volatile amines are suggested where these are commonly accepted practice or applicable, with the applicability described in the table notes.
Steam purity is a major subject of the document. Salt and silica carried over from boiler water contaminate superheaters and turbine blades, causing deposition and corrosion. The document discusses, in Section 5 and in Section 6.2 (iron, copper, hardness, and suspended solids), the question of using higher-purity water than required for the operating pressure — a practice that is not always justified. Control of carryover depends on limiting boiler-water concentrations, ensuring effective steam-water separation, maintaining adequate blowdown, and, where needed, using internal measures such as steam washing.
The document prescribes recommended chemical control analyses covering boiler-water phosphate, pH, alkalinity, conductivity, hardness, dissolved oxygen, silica, iron, copper, suspended solids, and TDS, with guidance on sampling and testing. Analysis frequency should be matched to boiler load, feedwater quality fluctuations, and historical operating data. Because special conditions (startup, shutdown, fluctuating loads) may demand tighter chemistry, monitoring should be intensified accordingly.