⚡ BS EN 61869 is the British Standards series implementing European Norm EN 61869 (identical to IEC 61869) for instrument transformers. Prepared by UK Technical Committee PEL/38 (Instrument transformers), it supersedes the earlier EN 60044 series. Instrument transformers transform high voltage and large current into secondary quantities acceptable to measuring and protective devices, and are the fundamental equipment for metering, measurement, protection and monitoring in power systems. The series defines the general and additional requirements for each type and is the core reference for the design, manufacture, testing and selection of instrument transformers.
The series applies to current transformers, voltage transformers, combined transformers, capacitor voltage transformers and low-power instrument transformers for measurement and protection. Part 1 gives general requirements (definitions, accuracy classes, ratings, insulation, tests and marking); the parts give additional requirements by transformer type.
Instrument transformers must satisfy both measurement accuracy (metering) and protection characteristics (e.g. composite error and transient behavior of CTs; voltage and phase-angle errors of VTs). Their accuracy class, secondary burden, insulation level and temperature rise are the key selection parameters, and the standard gives unified definitions and test methods.
| Standard | Title | Content Summary | Status |
|---|---|---|---|
| BS EN 61869-1:2009 | General requirements | General requirements: definitions, accuracy, ratings, insulation and tests | Published 2009; from IEC 61869-1:2007 (with European modifications) |
| BS EN 61869-2:2012 | Additional requirements for current transformers | Additional requirements for CTs (composite error, protection classes, transient) | Published 2012; supersedes EN 60044-1/-6 |
| BS EN 61869-3:2011 | Additional requirements for inductive voltage transformers | Additional requirements for inductive VTs | Published 2011; supersedes EN 60044-2 |
| BS EN 61869-4:2014 | Additional requirements for combined transformers | Additional requirements for combined (current+voltage) transformers | Scan version |
| BS EN 61869-5:2011 (2015) | Additional requirements for capacitor voltage transformers | Additional requirements for capacitor voltage transformers (CVT) | Scan version |
| BS EN 61869-6:2016 | Additional general requirements for low-power instrument transformers | Additional requirements for low-power instrument transformers (LPIT, electronic/sensing) | Scan version |
Part 1 specifies rated primary/secondary values, accuracy classes, secondary burden, insulation level, temperature rise, mechanical strength and test requirements, and defines the nameplate and marking. The general requirements apply to all types and are the reference basis for the parts.
Part 2 specifies accuracy for measuring classes (e.g. 0.2/0.5) and protection classes (e.g. 5P, 10P, TP types), the composite-error limits and transient characteristics (time constant, remanence factor, etc.), ensuring correct protection operation under short-circuit and transient conditions.
Part 3 specifies the voltage error and phase displacement, rated voltage factor and ferroresonance behavior of inductive VTs; Part 4 covers combined current+voltage transformers; Part 5 covers capacitor voltage transformers (CVT), whose accuracy is affected by the capacitor divider and intermediate transformer, requiring special transient-response verification.
Part 6 addresses low-power instrument transformers (LPIT), including Rogowski coils, electronic sensing and transformers with digital interfaces, specifying output, accuracy, insulation and EMC requirements to meet the needs of smart substations and digital metering.