BS EN 61189 — Test Methods for Electrical Materials, Printed Boards and Other Interconnection Structures and Assemblies

Test Methods for Electrical Materials, Printed Boards and Other Interconnection Structures and Assemblies

🔬 BS EN 61189 is the British Standard implementing the EN 61189 series, corresponding to IEC 61189, covering test methods for electrical materials, printed boards and other interconnection structures and assemblies. It is developed within IEC/TC 91 (Electronics assembly technology), with the UK represented by EPL/501. The value of the family is that it turns materials-to-process-to-performance questions in PCB manufacturing and electronic assembly into standardised, repeatable tests: from the melting temperature of solder alloys, to the relative permittivity and loss tangent of base materials at high frequency, to the general test procedures for interconnection structures. The eight documents in this batch span editions from 2013 to 2016.

💡 High-frequency operation is a dominant trend in electronics. RF modules, 5G communications and high-speed digital circuits are extremely sensitive to the dielectric constant (Dk) and loss tangent (Df) of the board material, and the reproducible measurement methods of the 61189 series are the precondition for quantitative acceptance of those materials.

1. Series Overview 📌

BS EN 61189 uses a “part plus numbered method” structure: topics are assigned to part numbers (Part 2 for interconnection-structure materials, Part 3 for printed boards, Part 5 for assemblies), and each test method carries an additional identifier (for example -719 or -721). The eight files in this batch span several parts and reflect a multi-level test demand from material level, through board level, to assembly level.

⚠️ Several documents in this series are scanned versions whose full text could not be optically recovered; the related content has been prepared from public-domain knowledge. The authoritative source is the officially published BSI version.

2. Structure and Technical Contents 🧱

StandardYearCore subjectObject
BS EN 61189-112013Measurement of melting temperature or melting temperature ranges of solder alloysDTA/DSC thermal analysis of lead-free and leaded solders
BS EN 61189-2-7192016Relative permittivity and loss tangent of materials for interconnection structures (500 MHz to 10 GHz)High-frequency dielectric characterisation
BS EN 61189-2-7212015Measurement of permittivity and loss of copper-clad laminate at microwave frequencies using a split-post dielectric resonator (SPDR)Non-destructive measurement of CCL
BS EN 61189-3-7192016Test methods for printed boards (interconnection structures)PCB structural and performance testing
BS EN 61189-5-12016General methods for assemblies (1)Soldered assemblies and placement quality
BS EN 61189-5-22015General methods for assemblies (2)Solder joint reliability related tests
BS EN 61189-5-32015General methods for assemblies (3)Cleanliness, solderability and others
BS EN 61189-5-42015General methods for assemblies (4)Stress and environmental tests

3. Key Technical Requirements 🔧

3.1 Solder melting temperature measurement (Part 11)

The melting temperature of a solder alloy determines the setting of the reflow oven profile. Part 11 prescribes thermal analysis (differential thermal analysis DTA or differential scanning calorimetry DSC) to determine the melting temperature or melting temperature range of the alloy. A eutectic alloy yields a single melting peak, while a non-eutectic system gives the temperature interval between the solidus and the liquidus, providing the basis for setting the process window.

3.2 High-frequency dielectric measurement (Parts 2-719 / 2-721)

Part 2-719 covers the measurement of relative permittivity and loss tangent from 500 MHz to 10 GHz for interconnection structure materials; Part 2-721 addresses copper-clad laminates, using a split-post dielectric resonator (SPDR) for non-destructive measurement at microwave frequencies. Both methods stress sample flatness, thickness and copper treatment, because the accuracy of Dk/Df measurement depends strongly on geometry and boundary conditions.

3.3 Assembly-level tests (Part 5 series)

The Part 5 sub-documents address assembled electronic assemblies: soldering quality inspection, solder-joint reliability, solderability, cleanliness and stress tests. Unlike material-level tests, assembly-level tests focus on the combined result of the process chain, and test samples are usually taken from production to represent the real manufacturing state.

🚨 When measuring high-frequency dielectric parameters, surface roughness, thickness measurement error and the calibration state of the resonator can affect Dk/Df results by orders of magnitude. Calibration and sample conditioning must follow the standard before any measurement, otherwise the data has no comparative value.

4. Engineering Practice 🛠️

  • 📡 High-frequency laminate selection: RF power amplifiers and antenna feeder boards use Part 2-721 data to select low-loss laminates and control attenuation and impedance.
  • 🔧 Reflow process setting: the melting point obtained per Part 11 sets the preheat, peak and cooling temperatures.
  • 🏭 Incoming inspection of CCL: sample Dk/Df per 2-719/2-721 and only start volume production when figures agree with supplier data.
  • 🔎 Yield analysis: use Part 5 methods to locate cold joints, skewing and cleaning residues and improve the process window.

5. Frequently Asked Questions ❓

❓ Q: Do 61189 and IPC test methods conflict?
A: The goals are the same but the systems differ. 61189 is the official IEC/EN/BS standard while IPC is an industry practice. Where a contract or regulation requires 61189, it prevails, and an equivalence comparison should be made if needed.
❓ Q: Why is the SPDR resonator needed for permittivity measurement?
A: At microwave frequencies, transmission-line methods impose demanding sample preparation, while the split-post dielectric resonator exploits its high Q-factor to give non-destructive, high-accuracy measurement of copper-clad boards, making it ideal for outgoing and incoming inspection.
❓ Q: Should DTA or DSC be used for melting point determination?
A: Both can observe the phase-change endothermic peak; the standard usually allows either according to equipment availability, as long as heating rate, sample mass and crucible material are kept consistent to preserve comparability.
❓ Q: Can the test parameters of the scanned parts be cited directly?
A: The scanned parts are summarised from public-domain knowledge and are usable as background for the procedure; for formal reports and pass/fail decisions always cite the controlled BSI text.
❓ Q: Do these methods apply to flexible boards?
A: Some methods (such as dielectric measurement) are sensitive to sample flatness; flexible boards need the sample-holding or conditioning treatment per the applicability notes of the standard, or a dedicated method may be required.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *