BS EN 61143 – X-t Recorder Electrical Measuring Instruments Standard Series

Electrical measuring instruments — X-t recorders

📐 BS EN 61143 is the UK adoption of the IEC 1143 series (later renumbered IEC 61143), specifying definitions, classification, reference conditions, intrinsic errors, nominal range of use and additional test methods for X-t recorders — self-recording electrical measuring instruments that plot the measured variable (t) against time (X). The series has two parts: Part 1 gives the generic definitions and requirements; Part 2 gives recommended additional test methods. It applies to instruments that produce a continuous graphic record of electrical or non-electrical quantities in industrial process recording, power monitoring and laboratory data acquisition.

💡 In practice the core value of an X-t recorder is to plot a time-varying measured quantity as a continuous curve on paper or digital media. BS EN 61143 makes recorders from different makers comparable through a unified terminology and error model.

1. Scope and Structure of the Series 📌

BS EN 61143 is structured in two parts covering the basic specification and the test methods:

StandardTitleSubjectAdoption
BS EN 61143-1:1994Electrical measuring instruments — X-t recorders — Part 1: Definitions and requirementsDefinitions and requirementsIdentical to IEC 1143-1:1992 (incl. A1:1997)
BS EN 61143-2:1994Electrical measuring instruments — X-t recorders — Part 2: Recommended additional test methodsRecommended additional test methodsIdentical to IEC 1143-2:1992

Part 1 covers description, classification and compliance, reference conditions and intrinsic errors, nominal range of use and variations, further electrical and mechanical requirements, constructional requirements, information/markings/symbols, terminal markings and compliance tests. Part 2 adds recommended additional test methods: intrinsic error test, additional error due to zero displacement, mutual influence of multiple measuring circuits, influence of parasitic quantities, and dynamic performance (response time, frequency response range, overshoot).

2. Definitions, Classification and Reference Conditions 🔧

The standard establishes a rigorous definitional framework. Recorders are classified by recording method, drive method and measuring-circuit type, and the manufacturer must clearly mark reference values, reference ranges and nominal ranges of use. Reference conditions are the set of conditions — with each influence quantity held within a stated tolerance — under which intrinsic error is determined; Table 1 lists these conditions and their test tolerances.

⚠️ Intrinsic error is the error under reference conditions, not the field operating error. When selecting a recorder always combine it with the additional variations caused by influence quantities inside the nominal range of use to assess true accuracy.

3. Nominal Range of Use and Permissible Variations 🔥

Table 2 defines the limits of the nominal range of use and the corresponding permissible variations. When an influence quantity (ambient temperature, humidity, external magnetic field, supply voltage, etc.) deviates from the reference condition but stays within the nominal range of use, the recorder is allowed an additional variation beyond intrinsic error. Designers must confirm that the combined error of the recorded curve still meets the measurement task under expected site conditions.

ConceptMeaningEngineering role
Reference conditionsConditions for influence quantities when intrinsic error is fixedLaboratory calibration basis
Intrinsic errorMaximum error under reference conditionsBasic instrument accuracy
Nominal range of useLimits within which influence quantities may deviateField applicability boundary
Permissible variationUpper limit of additional error within nominal rangeBasis for field error assessment

4. Additional Test Methods and Engineering Practice 🛠️

Part 2 recommends several additional test methods for a fuller evaluation of recorder performance:

  • Intrinsic error test: measures deviation between the recorded curve and the theoretical value under reference conditions.
  • Additional error due to zero displacement: examines drift of the zero after energisation.
  • Mutual influence of channels: assesses cross-interference between multiple measuring circuits (critical for multi-channel recorders).
  • Influence of parasitic quantities: common-mode and series/parallel-mode interference tests for immunity.
  • Dynamic performance: response time, frequency response range and overshoot, reflecting ability to follow rapidly changing signals.
✅ When choosing an X-t recorder, first define the signal rate-of-change and site environment, then cross-check the manufacturer’s accuracy against the BS EN 61143 error model — never treat intrinsic error as the field error.

6. Standard Links and Recorder Selection 🔗

BS EN 61143 is not isolated; it sits with BS EN 61010 (safety of electrical measuring equipment), BS EN 60688 (measuring transducers) and BS EN 61140 (protection against electric shock) in the complete electrical-measurement specification chain. An X-t recorder normally works as a secondary instrument with primary sensors (thermocouples, RTDs, current transformers, pressure transmitters), so its input range, input impedance and overload capability must match the front-end sensor. Part 1 specifies the input circuit, range switching and chart specifications, all to be checked at selection.

In practice recorders are used for continuous monitoring and historical traceability at power plants, substations and chemical plants. Beyond accuracy, pay attention to chart speed, recording bandwidth, chart-drive reliability, pen/printer life and communication interfaces (RS-232, RS-485, analogue output). For long unattended duty, prefer models with data storage and power-loss continuation, and evaluate stability under supply fluctuation and EMI per the standard’s test methods.

Selection aspectFocusRelated standard
SafetyInsulation, contact protectionBS EN 61010
Input matchingRange, impedance, overloadBS EN 60688
Error modelIntrinsic + additional variationBS EN 61143
Data interfaceDigital output, protocolEnterprise / system spec

Overall, recorder selection should follow “define the measurement task and site environment, then check the error model, finally verify safety and interface”, combining BS EN 61143 with companion standards to ensure both credible recorded data and long-term site safety and maintenance.

5. Frequently Asked Questions ❓

❓ Q: What is the relationship between BS EN 61143 and IEC 1143?
A: BS EN 61143 is the UK adoption of the IEC 1143 series (later IEC 61143), identical in content; Part 1 corresponds to IEC 1143-1:1992 incl. A1:1997 and Part 2 to IEC 1143-2:1992.
❓ Q: How do intrinsic and field errors differ?
A: Intrinsic error applies only under reference conditions; field error also includes additional variations from influence quantities within the nominal range of use plus installation, supply and electromagnetic effects, which are often far larger.
❓ Q: Are the Part 2 test methods mandatory?
A: Part 2 is titled “Recommended additional test methods” and is recommendatory, used to evaluate dynamic and immunity performance more completely; whether to apply it is decided by the product specification or contract.
🔍 Q: What matters most for multi-channel recorders?
A: Focus on the “mutual influence of multiple measuring circuits” and the “parasitic quantity (common/series mode) interference” tests of Part 2, to ensure channel crosstalk and site EMI do not corrupt the recorded curves.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply