BS EN 60079 — Explosive Atmospheres Equipment and Explosion-Protection Standard Series

Explosive atmospheres: equipment and protection systems (BS EN 60079 series, derived from IEC 60079)

📐 BS EN 60079 is the British national implementation by BSI of the CENELEC EN 60079 series, which is identical or closely correlated with the IEC 60079 family — the global reference for the design, selection, installation and maintenance of electrical equipment and protection systems in explosive atmospheres (flammable gases, vapours, dusts and fibres). The series comprises around 30 documents covering general equipment requirements, each major type of protection (flameproof enclosure “d”, increased safety “e”, intrinsic safety “i”, pressurization “p”, encapsulation “m”, oil immersion “o”, powder filling “q”), area classification for gas and dust, installation, inspection and maintenance. It is the compliance cornerstone for the oil, chemical, pharmaceutical, mining, food-processing and coating industries.

💡 In practice, BS EN 60079 works hand in hand with the EU ATEX directives (2014/34/EU for equipment and 1999/92/EC for workplaces): the equipment must satisfy the relevant EN 60079 part before CE/Ex marking permits use in explosive atmospheres.

1. Scope and Overall Framework of the Series 📌

BS EN 60079 guides the design, selection, installation and maintenance of electrical equipment and protection systems for explosive atmospheres, as well as hazardous-area assessment. It is organized into parts: part 0 states general equipment requirements; part 1 covers flameproof enclosures “d”; part 7 increased safety “e”; part 11 intrinsic safety “i”; part 18 encapsulation “m”; while parts 10-1 (gas) and 10-2 (dust) address area classification. The series closely follows IEC 60079, marking CENELEC common modifications adopted in the UK where they occur.

⚠️ The series covers only the technical level of equipment and area classification. It does not replace statutory hazardous-area assessments, permit-to-work regimes or personnel competence requirements — legal compliance with fire, health & safety legislation and the ATEX directives remains mandatory.

2. Series Composition and Key Technical Items 🔧

The table below lists representative parts of the series and their technical subjects:

StandardSubjectKey technical content
BS EN 60079-0Equipment — General requirementsCommon requirements: terminology, temperature classes, Equipment Protection Levels (EPL), mechanical strength, joints, fasteners, earthing, marking and test procedures
BS EN 60079-1Flameproof enclosures “d”Enclosure withstands internal explosions without propagating; flange gaps, joint widths, shaft clearances and type tests
BS EN 60079-2Pressurization “p”Maintains positive internal pressure with protective gas to exclude the explosive mixture
BS EN 60079-7Increased safety “e”Enhanced construction, insulation and temperature rise for apparatus with no arcing parts
BS EN 60079-10-1Area classification — GasZone 0, 1, 2 classification principles and extent estimation
BS EN 60079-10-2Area classification — DustZone 20, 21, 22 classification principles
BS EN 60079-11Intrinsic safety “i”Energy limiting so circuits cannot ignite the atmosphere; ia/ib levels
BS EN 60079-14Electrical installations design/selection/erectionDesign, selection and erection of electrical installations (used with part 17)
BS EN 60079-17Inspection and maintenanceInspection, periodic verification and maintenance of Ex installations
BS EN 60079-18Encapsulation “m”Potentially arcing parts embedded in resin to isolate them

3. Key Technical Requirements and Protection Principles 🔥

Part 0 establishes for all Ex equipment the temperature classes (T1–T6, maximum surface temperature from 450 °C down to 85 °C), the EPL framework (Ga/Gb/Gc for gas, Da/Db/Dc for dust) and the classification of Group II (gas) and Group III (dust) apparatus. Each protection technique then adds its own detail:

  • Flameproof enclosure “d” (60079-1): the enclosure must withstand the internal explosion pressure without damage, and every joint gap (plain, cylindrical, threaded) must cool the escaping products below the ignition temperature of the outside atmosphere. Quantified limits cover maximum experimental safe gap (MESG)-related geometry, joint widths and clearances, bearing gaps, fastener strength and locking.
  • Intrinsic safety “i” (60079-11): voltage, current, capacitance and inductance are limited so the circuit cannot ignite the surrounding atmosphere in normal or fault conditions. Level ia (two independent faults) is accepted for Zone 0; ib for Zone 1.
  • Increased safety “e” (60079-7): relies not on containment but on enhanced insulation, creepage distances, clearances, winding temperature rise and terminal construction to prevent dangerous temperatures or sparks in normal service.
  • Pressurization “p” (60079-2): instrument air or inert gas keeps the enclosure pressurized; px/py/pz subtypes govern purge flow, pressure monitoring and interlocking.
🚨 Isolation between intrinsically safe and non-intrinsically safe circuits, damage or corrosion of flameproof joints, and loss of pressurization interlock are the most common causes of protection failure in the field. Installation and maintenance must follow 60079-14 and 60079-17; any unassessed modification can invalidate the Ex marking.

4. Area Classification and Engineering Practice 🛠️

BS EN 60079-10-1 (gas) and -10-2 (dust) provide the methodology for hazardous-area classification. Gas atmospheres are divided by frequency and duration of occurrence into Zone 0 (continuous or long-lasting), Zone 1 (likely in normal operation) and Zone 2 (short-lived under abnormal conditions); dust atmospheres map to Zones 20/21/22. Classification inputs include the release-source grade (continuous, primary, secondary), ventilation/dilution capability and accumulation risk. Equipment selection then follows the required EPL: Zone 1 typically calls for flameproof “d” or intrinsic safety; Zone 2 may use increased safety “e” or non-sparking apparatus.

💡 In the UK adoption of 60079-10-1, the national committee pointed out that the ventilation rate (volume of air per unit time) relative to the release rate is the decisive dilution factor, with “ventilation velocity” only a secondary effect, and that a Zone 2 NE classification should only apply to source pressures below about 10 barg. These national caveats encourage users to cross-check the worked examples in the informative annexes.

5. Frequently Asked Questions ❓

❓ Q: How do BS EN 60079 and ATEX relate?
A: BS EN 60079 is the technical standard defining how Ex equipment is designed, tested and marked; ATEX is the EU legal framework covering market placement (2014/34/EU) and workplace safety (1999/92/EC). Equipment must meet the relevant EN 60079 part and complete conformity assessment before receiving the Ex mark.
❓ Q: Can flameproof “d” and intrinsically safe “i” be combined?
A: Yes. Non-intrinsically safe circuits are inside the flameproof enclosure while sensors are fed through associated apparatus (safety barriers) that limit energy. Each part is designed and certified to its own requirements.
❓ Q: How to tell Zones 0, 1 and 2 apart quickly?
A: Judge by frequency and duration of the explosive mixture: Zone 0 is continuous/long-lasting (e.g. the vapour space above liquid in a tank), Zone 1 is occasionally present in normal operation, Zone 2 only briefly under abnormal faults. The zone determines the required EPL and protection type.
🔍 Q: Why are some documents in the series written from public domain knowledge?
A: Some digital copies of individual parts are scanned images (READABLE=0) whose text cannot be extracted word-for-word; those sections are summarized from publicly available domain knowledge and are marked as “scanned version, written according to public domain knowledge”.
🔒