BS EN 60931 — Shunt Power Capacitors of the Non-Self-Healing Type for A.C. Systems with Rated Voltage up to and Including 1 kV Standard Series

General Requirements and Internal Fuses (EN/IEC 60931 Series)

⚙️ BS EN 60931 is the British Standard adopting, identically, the IEC 60931 European standard series for shunt power capacitors of the non-self-healing type for a.c. systems with rated voltage up to and including 1 kV. Developed by IEC/TC 33 (Power capacitors), approved by CENELEC as EN 60931, and adopted in the UK by committee PEL/33, it gives requirements and test methods. Non-self-healing capacitors, in contrast to self-healing metallised-film types, cannot restore their insulation after dielectric breakdown and rely on internal fuses to isolate faulted elements. Such capacitors are widely used for power factor correction and harmonic management in low-voltage distribution networks.

⚠️ In this batch, BS EN 60931-1 (general requirements) is a scanned document (SCAN); its specific clause details are written based on publicly available domain knowledge and standard catalogue information. The corresponding part of this article is scanned-version content, written from public domain knowledge.

1. Scope and General Framework 📌

The BS EN 60931 series applies to shunt power capacitors for a.c. systems with rated voltage up to and including 1 kV, i.e. non-self-healing power capacitors used for reactive power compensation in low-voltage networks. The series structure is:

  • Part 1: General requirements — Performance, testing and rating — Safety requirements — Guide to installation and operation: general requirements covering ratings, performance, tests, safety, and installation/operation guidance.
  • Part 3: Internal fuses: requirements and test methods for internal fuses of non-self-healing shunt power capacitors.

The documents in this batch are BS EN 60931-1:1998 (scanned) and BS EN 60931-3:1997 (corresponding to IEC 60931-3:1996, with 1999 update). ICS classification is 31.060.70 (Power capacitors).

💡 Non-self-healing capacitors ensure safe operation through a “faulted-element isolation” strategy: when an individual element breaks down, the internal fuse (Part 3) or external fuse isolates it, allowing the capacitor bank to continue operating or to be taken out in an acceptable state.

2. Series Composition and Technical Points 🔧

StandardTitleFocusIEC EquivalentNote
BS EN 60931-1:1998General requirements — Performance, testing and rating — Safety — Installation and operationRatings, performance, tests, safety, installation/operationIEC 60931-1Scanned (SCAN)
BS EN 60931-3:1997Internal fusesInternal fuse requirements and testsIEC 60931-3:1996Readable text

1. General Requirements (Part 1, Scanned)

Based on public domain knowledge, Part 1 covers the following (this section is scanned-version content, written from public domain knowledge):

  • Ratings: rated voltage, rated output (kvar), rated frequency, and rated current.
  • Performance requirements: capacitance tolerance, losses, temperature category, overvoltage and overcurrent withstand capability.
  • Test programme: capacitance measurement, dielectric loss, withstand voltage test (power-frequency/d.c.), discharge test, sealing test, and destructive tests.
  • Safety requirements: discharge devices, terminal protection, enclosure, and earthing requirements.
  • Installation and operation guidance: compensation configuration, fuse coordination, and harmonic/inrush suppression recommendations.

2. Internal Fuses (Part 3)

Part 3 specifies requirements for internal fuses of non-self-healing shunt power capacitors (based on readable text):

  • Fuse function: reliably isolates a faulted element on breakdown, preventing fault escalation and enclosure failure.
  • Fusing characteristics: specified melting time, melting current, and operating reliability.
  • Test methods: verification of fuse operating characteristics and endurance under specified fault conditions.
  • Coordination with the capacitor body: electrical and thermal coordination between the internal fuse and the capacitor element.
🚨 Capacitors are energy-storage devices; after de-energisation, internal charge may remain at dangerous voltage for a long time. Discharge fully via the discharge device and confirm the terminal voltage is zero before maintenance — never touch capacitor terminals directly.

3. Key Technical Requirements 🔬

Key technical requirements for non-self-healing shunt power capacitors include:

  • Capacitance tolerance: deviation of actual capacitance from rated value within specified limits, affecting compensation accuracy.
  • Overvoltage and overcurrent: the capacitor must withstand specified power-frequency overvoltage, switching overvoltage, harmonic currents, and inrush currents (e.g. energisation inrush).
  • Dielectric loss and temperature rise: dielectric loss tangent within limits, ensuring normal temperature rise is not exceeded.
  • Insulation and withstand voltage: power-frequency/d.c. withstand between terminals and between terminal and case.
  • Element isolation and fault protection: internal fuses or external protection reliably isolate faulted elements to prevent cascading faults.
💡 In reactive power compensation projects, the standard configuration of “fuse + contactor/switch + discharge resistor” is common: the fuse isolates a faulted capacitor, the contactor switches reactive power, and the discharge resistor ensures safety. Design the configuration according to capacitor standards and bank guidance.

4. Engineering Practice and Application 🛠️

  • 🔍 Selection: choose rated output and voltage by the required reactive power and system voltage; verify the harmonic environment and add reactors where necessary.
  • 🔧 Installation: capacitor banks should be fitted with discharge devices, fuses, and switching devices; wiring must meet current-carrying and heat-dissipation requirements.
  • 📊 Operation monitoring: monitor capacitor current, temperature rise, and harmonics; act promptly on element breakdown or abnormal capacitance.
  • 📋 Test acceptance: after installation, perform capacitance measurement, insulation testing, and discharge checks, and verify nameplate and documentation.

5. Frequently Asked Questions ❓

❓ Q: What is the difference between non-self-healing and self-healing capacitors?
A: Self-healing (metallised-film) capacitors restore insulation after dielectric breakdown and suit low-voltage compensation; non-self-healing capacitors cannot self-heal and rely on internal fuses or external protection to isolate faulted elements, often used where higher reliability or larger capacity is needed.
⚙️ Q: What is the function of the internal fuse?
A: When an individual element inside the capacitor breaks down, the internal fuse melts quickly, isolating the faulted element to prevent fault escalation, enclosure failure, or shutdown of the whole bank, ensuring safe operation.
🔌 Q: Why must capacitors be discharged before maintenance?
A: Capacitors store energy; even when de-energised they may retain a high-voltage charge, causing electric shock if touched. Discharge fully via the discharge device and confirm zero voltage before working.
📊 Q: How are capacitors selected in a harmonic environment?
A: In harmonic environments, assess the effect of harmonic currents and voltage distortion on capacitors, add tuning reactors where necessary, and choose capacitors with appropriate rated voltage to avoid overload and resonance.
🔒