๐ PD ISO/TS 17951 is a BSI Published Document covering the determination of fluoride in water using flow analysis (FIA and CFA). Fluoride is a common ion in drinking water and the environment: at appropriate levels it is beneficial to dental health, but at excessive levels it may cause fluorosis. Accurate determination of fluoride in water is therefore essential for water supply safety, public health and environmental monitoring. Part 1 uses flow injection analysis (FIA) with off-line distillation and spectrometric detection; Part 2 uses continuous flow analysis (CFA) with automated in-line distillation. The series was prepared by BSI Technical Committee EH/3/2 and published in July 2016.
PD ISO/TS 17951 applies to the determination of fluoride in various water samples (drinking water, surface water, groundwater, wastewater, etc.). Part 1 specifies a method using flow injection analysis (FIA) with off-line distillation followed by spectrometric detection. Part 2 specifies a method using continuous flow analysis (CFA) with automated in-line distillation. Both rely on the reaction of fluoride with a colour-forming reagent (e.g. lanthanum-alizarin complexone or a similar system) to form a coloured complex that is quantified spectrophotometrically.
| Part | Reference | Analytical Method | Pre-treatment |
|---|---|---|---|
| Part 1 | PD ISO/TS 17951-1:2016 | Flow injection analysis (FIA) | Off-line distillation + spectrometric detection |
| Part 2 | PD ISO/TS 17951-2:2016 | Continuous flow analysis (CFA) | Automated in-line distillation + spectrometric detection |
Both methods are based on the colour reaction of fluoride with a specific colour-forming reagent. In acid medium, fluoride undergoes a ligand-exchange reaction with lanthanum-alizarin complexone (or a similar metal-dye complex), changing the solution colour; the absorbance is proportional to the fluoride concentration. FIA injects a small sample volume into a continuously flowing carrier, where mixing and colour development occur in a reaction coil before entering a flow-cell detector. CFA delivers sample and reagents at a constant ratio via a peristaltic pump, passes through an on-line distillation and colour development stage, and enters the detector.
The distillation step converts fluoride to volatile fluorosilicic acid (HโSiFโ), which is carried over in a steam flow, condensed and collected, thus separating fluoride from the matrix. The automated in-line distillation of Part 2 integrates this step into the flow system for full automation.
Main interferences in fluoride determination come from coexisting cations and anions:
Distillation pre-treatment effectively removes these interferences. In addition, the standard specifies pH control with a buffer, addition of masking agents, optimisation of distillation conditions, and the use of standard addition or matrix matching to remove residual matrix effects.
Key reagents include: sodium fluoride stock and working standard solutions, colour reagent (lanthanum-alizarin complexone, etc.), buffer solution, masking agents, and acid for distillation. For apparatus, an FIA system comprises an injection valve, peristaltic pump, reaction coil, flow cell and spectrophotometric detector; a CFA system comprises a multi-channel peristaltic pump, in-line distillation device, mixing coils, air-segmentation device and detector.
A typical procedure is: sample collection and preservation โ distillation (off-line or in-line) โ reaction with colour reagent โ spectrophotometric detection โ quantification against a standard curve โ calculation and reporting. Each batch should include reagent blanks, duplicate samples and QC samples.