Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
⚡ PD CLC TS is the prefix under which BSI publishes CENELEC Technical Specifications (CLC/TS) as Published Documents (PD). A CLC/TS is a Technical Specification developed by the European Committee for Electrotechnical Standardization (CENELEC) for subjects still under development that are not yet formal EN standards; BSI implements it in the UK as a PD. Like a Draft for Development (DD), a PD is not a formal British Standard, but it provides a common technical convention in the field and complements the formal standard (EN). This batch collects 15 PD CLC/TS documents covering cable TV and interactive services networks, alarm transmission systems, surge protective device (SPD) selection and application, three-phase shore supply for rail vehicles, interoperability framework for home electronic systems, collection and de-pollution of end-of-life appliances, cable fire testing, electricity metering data exchange, railway energy consumption, commercial laundry/drying appliance performance, flue-gas measurement for gas appliances, and industrial process-control system evaluation.
All 15 documents in this batch are single-file series. Several are parts of CENELEC multi-part series (e.g. 50083-3-3, 50136-9, 50539-12, 50574-2, 61643-22, 62603-1), while others carry standalone numbers. The table below lists the complete inventory and subjects.
| Standard | Subject | ICS | Key Technical Content |
|---|---|---|---|
| PD CLC/TS 50083-3-3:2014 | Cable networks for TV, sound and interactive services — Part 3-3: Active wideband equipment — Measurement of maximum operating output level in the return path | 33.060.40 | Return-path maximum operating output level measurement for CATV active equipment |
| PD CLC/TS 50136-9:2013 | Alarm systems — Alarm transmission systems and equipment — Part 9: Requirements for common protocol for alarm transmission using the Internet protocol | 13.320; 33.040.40 | Voluntary common IP protocol for alarm transmission |
| PD CLC/TS 50539-12:2013 | Low-voltage SPDs — SPDs for specific application including d.c. — Part 12: Selection and application principles — SPDs connected to PV installations | 29.120.50 | SPD selection/application for photovoltaic installations |
| PD CLC/TS 50546:2013 | Railway applications — Rolling stock — 3-phase shore (external) supply system for rail vehicles | 29.280 | Three-phase shore supply for rail vehicles |
| PD CLC/TS 50560:2014 | Interoperability framework requirement specification | 35.240.99; 97.120 | IFRS for home electronic systems |
| PD CLC/TS 50574-2:2014 | Collection, logistics & treatment requirements for end-of-life household appliances containing volatile fluorocarbons or volatile hydrocarbons — Part 2: De-pollution specification | 13.030.30; 13.030.40; 97.030 | De-pollution technical specification for end-of-life appliances |
| PD CLC/TS 50576:2016 | Electric cables — Extended application of test results for reaction to fire | 13.220.40; 29.060.20 | Extended application (EXAP) of cable fire-test results |
| PD CLC/TS 50590:2015 | Electricity metering data exchange — Lower layer PLC profile using Adaptive Multi Carrier Spread-Spectrum (AMC-SS) modulation | 35.240.60; 91.140.50 | AMC-SS PLC lower-layer profile for meters |
| PD CLC/TS 50591:2013 | Specification and verification of energy consumption for railway rolling stock | 45.060.10 | Railway energy-consumption specification and verification |
| PD CLC/TS 50594:2015 | Tumble dryers for commercial use — Methods for measuring the performance | 97.060 | Commercial tumble-dryer performance tests |
| PD CLC/TS 50612:2016 | Portable electrical apparatus for measurement of combustion flue gas parameters — Guide to use in commissioning, servicing and maintaining gas-fired appliances | 13.040.40; 91.140.10 | Flue-gas analyser application guide for gas-appliance service |
| PD CLC/TS 50640:2015 | Clothes washing machines for commercial use — Methods for measuring the performance | 97.060 | Commercial washing-machine performance tests |
| PD CLC/TS 61643-22:2016 | Low-voltage SPDs — Part 22: SPDs connected to telecommunications and signalling networks — Selection and application principles | 29.240.01; 29.240.10 | SPD selection/application for telecom & signalling networks (from IEC 61643-22) |
| PD CLC/TS 62441:2012 | Safeguards against accidentally caused candle flame ignition for audio/video, communication and IT equipment | 35.260; 97.020 | Candle-flame ignition safeguards for equipment enclosures |
| PD CLC/TS 62603-1:2014 | Industrial process control systems — Guidelines for evaluating process control systems — Part 1: Specifications | 25.040.40 | Process-control system evaluation specification (from IEC/TS 62603-1) |
This batch contains two important SPD documents: PD CLC/TS 50539-12:2013 specifies selection and application principles for SPDs connected to photovoltaic (PV) installations, covering selection, installation position, connection and coordination of overvoltage protectors on both the d.c. and a.c. sides of PV systems; PD CLC/TS 61643-22:2016 specifies selection and application principles for SPDs connected to telecommunications and signalling networks, derived from IEC 61643-22:2015 with CENELEC common modifications, superseding DD CLC/TS 61643-22:2006. Both are the responsibility of PEL/37 (Surge arresters — high voltage), subcommittee PEL/37/1 (Surge arresters — low voltage).
With the spread of PV generation and communication systems in buildings, correct SPD selection is critical to lightning protection engineering: d.c.-side SPDs must account for the PV system’s maximum working voltage and short-circuit current, while signalling-network SPDs must preserve transmission band, insertion loss and the electrical characteristics of the protected interface. The documents give designers a mapping from “protected-object characteristics” to “SPD parameters”.
PD CLC/TS 50546:2013 specifies the three-phase shore (external) supply system for rail vehicles — the interface and system requirements for powering rolling stock from a ground-side three-phase supply in depots and workshops, enabling auxiliary systems to run when not under catenary; PD CLC/TS 50591:2013 specifies the specification and verification of energy consumption for railway rolling stock, giving definitions, measurement and verification methods for energy-consumption indicators (e.g. energy per tonne-kilometre, traction energy), providing a common basis for operator energy assessment and train procurement.
Both belong to the railway electrotechnical applications field (GEL/9 series): 50546 addresses “how to supply power” and 50591 addresses “how much energy is consumed”. With train energy efficiency and decarbonisation becoming a focus, the energy-accounting method of 50591 links with emission-accounting frameworks such as ISO 14064, and is significant for OEM and operator energy-saving assessment.
PD CLC/TS 50576:2016 specifies the extended application of cable reaction-to-fire test results, superseding PD CLC/TS 50576:2014, the responsibility of GEL/20 (Electric cables), subcommittee GEL/20/18 (Electric cables — fire testing). It allows the fire/heat-release results measured on a specific cable size per standards such as EN 50399 to be extended, via “extended application rules (EXAP)”, to other sizes with similar dimensions and construction, reducing repeated testing and supporting CPR (Construction Products Regulation) fire-class certification of cables.
PD CLC/TS 50612:2016 provides a guide to the use of portable flue-gas analysers in commissioning, servicing and maintaining gas-fired appliances, covering CO/CO₂/O₂ measurement, flue-gas temperature, combustion efficiency and safety interlocks, supporting on-site commissioning and emission testing of boilers and water heaters. It is the responsibility of EXL/31 (Equipment for explosive atmospheres), subcommittee EXL/31/1 (Gas detectors).
PD CLC/TS 50136-9:2013 specifies requirements for a common protocol for alarm transmission using the Internet protocol, Part 9 of the EN 50136 (alarm transmission systems) series. The standard explicitly states that this common IP protocol specification is voluntary: any Internet protocol meeting EN 50136-1:2012 may be used, providing an optional unified specification for IP-based transmission of alarm signals. It is the responsibility of GW/1 (Electronic security systems), subcommittee GW/1/5 (Transmission equipment and networks).
PD CLC/TS 62441:2012 specifies safeguards against accidentally caused candle-flame ignition of audio/video, communication and IT equipment, identical to IEC/TS 62441:2011, superseding DD CLC/TS 62441:2007. The UK national committee abstained from the vote (no national consensus), but publication was necessary because of an undated reference in BS EN 60065:2002. The document provides a candle-flame ignition test for equipment enclosures — a supplementary fire-safety requirement for consumer electronic products.
PD CLC/TS 50590:2015 specifies the lower-layer power-line communication (PLC) profile using Adaptive Multi Carrier Spread-Spectrum (AMC-SS) modulation for electricity metering data exchange, working with the EN 62056 (DLMS/COSEM) series for smart-meter low-voltage PLC meter reading, the responsibility of PEL/13 (Electricity meters). It defines the physical/link-layer modulation, frame structure and transmission parameters — an important technical convention for European smart-metering PLC communications.
PD CLC/TS 50083-3-3:2014 specifies methods of measurement of the maximum operating output level in the return path for active wideband equipment for cable networks, Part 3-3 of the EN 50083 series for TV-signal, sound-signal and interactive-services cable networks. The return path is the key uplink for interactive services (e.g. broadband access) in two-way cable networks; the document provides a unified measurement/evaluation method for the return-path output capability of active equipment, the responsibility of EPL/100/4 (Cable distribution equipment and systems).